ZnO-6LiF/polystyrene composite scintillator for thermal neutron radiation detection

被引:3
|
作者
Sahani, R. M. [1 ]
Pandya, Arun [1 ]
Dixit, Ambesh [2 ]
机构
[1] Def Lab DRDO, Nucl Radiat Management & Applicat Div, Jodhpur 342011, Rajasthan, India
[2] Indian Inst Technol, Dept Phys, Adv Mat & Device A MAD Lab, Jodhpur 342030, Rajasthan, India
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2023年 / 94卷 / 02期
关键词
ALPHA-PARTICLE; ZNO;
D O I
10.1063/5.0126282
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
We report the preparation of the ZnO-6LiF composite with a polystyrene (PS) polymer as a host using the solution mixing process. 6LiF acts as a converter material that absorbs a thermal neutron and produces alpha particles, which excites ZnO micro-particles, resulting in UV-vis photons' emission. The free-standing ZnO-6LiF/PS composite film is coupled to a photomultiplier tube (PMT). 241Am-Be (1Ci) is used as the neutron radiation source for measuring the response. We compared the response of the composite scintillator consisting of (i) natural LiF and (ii) 95% 6Li enriched LiF (6LiF). The increased pulse heights are recorded for 95% 6Li enriched, i.e., 6LiF converter. It confirms the generation of alpha particles after the absorption of a neutron in 6LiF. Furthermore, ZnO and 6LiF are considered in different weight proportions, 2:1, 1:1, and 1:2, keeping the total loading 50% (w/w) of polystyrene. The ZnO:6LiF (1:1)/PS composite showed higher scintillation pulse heights than the other two composites. Repetitive measurements are performed for the ZnO-6LiF(1:1)/PS composite, showing +/- 5% variation in respective responses. We also investigated the impact of different counting times and source-to-detector responses for the ZnO-6LiF(1:1)/PS composite. The response increases linearly with neutron dose, exhibiting a sensitivity of similar to 203 counts/mu Sv. Neutron measurement counts at different source-to-detector distances have a similar trend as that of neutron dose measured by using a neutron dosimeter. Thus, this work demonstrated the potential of the ZnO-6LiF/PS composite, coupled to PMT for detecting thermal neutron radiation. Published under an exclusive license by AIP Publishing. https://doi.org/10.1063/5.0126282
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Evaluation of boron-enriched plastic scintillator for thermal neutron detection
    Porosev, V. V.
    Savinov, G. A.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (06)
  • [32] A 16-ch module for thermal neutron detection using ZnS:6LiF scintillator with embedded WLS fibers coupled to SiPMs and its dedicated readout electronics
    Mosset, J-B
    Stoykov, A.
    Greuter, U.
    Gromov, A.
    Hildebrandt, M.
    Panzner, T.
    Schlumpf, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 845 : 494 - 498
  • [33] A new type of thermal-neutron detector based on ZnS(Ag)/LiF scintillator and avalanche photodiodes
    Marin, V. N.
    Sadykov, R. A.
    Trunov, D. N.
    Litvin, V. S.
    Aksenov, S. N.
    Stolyarov, A. A.
    TECHNICAL PHYSICS LETTERS, 2015, 41 (09) : 912 - 914
  • [34] A new type of thermal-neutron detector based on ZnS(Ag)/LiF scintillator and avalanche photodiodes
    V. N. Marin
    R. A. Sadykov
    D. N. Trunov
    V. S. Litvin
    S. N. Aksenov
    A. A. Stolyarov
    Technical Physics Letters, 2015, 41 : 912 - 914
  • [35] CHARACTERISTICS OF ZnS(Ag) + 6LiF SCINTILLATOR-BASED DETECTOR USED AS A NEUTRON DOSIMETER
    Kolesnikov, S. V.
    Denisenko, A. P.
    Ryabeva, E. V.
    ATOMIC ENERGY, 2023, 133 (04) : 212 - 216
  • [36] Characteristics of ZnS(Ag) + 6LiF Scintillator-Based Detector Used as a Neutron Dosimeter
    S. V. Kolesnikov
    A. P. Denisenko
    E. V. Ryabeva
    Atomic Energy, 2023, 133 : 212 - 216
  • [37] Tl-Doped CsI/6LiBr Scintillator for Thermal Neutron Detection With Ultrahigh Light Yield
    Yajima, Ryuga
    Kamada, Kei
    Yoshino, Masao
    Sasaki, Rei
    Horiai, Takahiko
    Murakami, Rikito
    Kim, Kyoung Jin
    Kochurikhin, Vladimir V. V.
    Ohashi, Yuji
    Yamaji, Akihiro
    Kurosawa, Shunsuke
    Yokota, Yuui
    Sato, Hiroki
    Toyoda, Satoshi
    Hanada, Takashi
    Yoshikawa, Akira
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2023, 70 (07) : 1331 - 1336
  • [38] THERMAL-NEUTRON DETECTION AND IDENTIFICATION IN A LARGE VOLUME WITH A NEW LI-6 LOADED LIQUID SCINTILLATOR
    AITBOUBKER, S
    AVENIER, M
    BAGIEU, G
    CAVAIGNAC, JF
    COLLOT, J
    FAVIER, J
    KAJFASZ, E
    KOANG, DH
    STUTZ, A
    VIGNON, B
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 277 (2-3): : 461 - 466
  • [39] Fast neutron detection with 6Li-loaded liquid scintillator
    Fisher, B. M.
    Abdurashitov, J. N.
    Coakley, K. J.
    Gavrin, V. N.
    Gilliam, D. M.
    Nico, J. S.
    Shikhin, A. A.
    Thompson, A. K.
    Vecchia, D. F.
    Yants, V. E.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 646 (01): : 126 - 134
  • [40] AN IMPROVED LI-6-LOADED GLASS SCINTILLATOR FOR NEUTRON DETECTION
    FIRK, FWK
    SLAUGHTER, GG
    NUCLEAR INSTRUMENTS & METHODS, 1961, 13 (03): : 313 - 316