Customized 3D-printed molds for high dose-rate brachytherapy in facial skin cancer: First clinical experience

被引:6
|
作者
Chatzikonstantinou, Georgios [1 ]
Diefenhardt, Markus [1 ,2 ]
Fleischmann, Maximilian [1 ]
Meissner, Markus [3 ]
Scherf, Christian [1 ]
Trommel, Martin [1 ]
Ramm, Ulla [1 ]
Roedel, Claus [1 ,2 ,4 ]
Tselis, Nikolaos [1 ]
Licher, Joerg [1 ]
机构
[1] Goethe Univ Frankfurt Main, Univ Hosp, Dept Radiotherapy & Oncol, Frankfurt, Germany
[2] Frankfurt Canc Inst, Frankfurt, Germany
[3] Goethe Univ Frankfurt Main, Univ Hosp, Dept Dermatol Venereol & Allergol, Frankfurt, Germany
[4] German Canc Consortium DKTK, German Canc Res Ctr DKFZ, Partner Site Frankfurt Main, Frankfurt, Germany
关键词
BASAL-CELL CARCINOMA; APPLICATORS; TUMORS;
D O I
10.1111/ddg.14944
中图分类号
R75 [皮肤病学与性病学];
学科分类号
100206 ;
摘要
Background and ObjectiveRadiotherapy of elderly, frail patients with facial skin cancer in proximity to critical organs is challenging. This is the first report on clinical experience with facial skin cancer treated by individualized 3D-printer-based mold high-dose-rate (HDR) brachytherapy (BT). Patients and MethodsFifteen patients not eligible for radical surgery or definitive external beam radiotherapy (EBRT) were treated with 3D-printer-based mold HDR-BT. Patient selection and treatment were in accordance with multidisciplinary tumor board recommendations. Clinical response, toxicity and cosmesis were analyzed. ResultsMedian age was 77 years. Histology revealed squamous cell carcinoma in seven, basal cell carcinoma in five, melanoma in situ in one, Lentigo maligna in one, and melanoma in one patient, respectively. Median prescription dose was 39 Gy delivered in once-daily fractions of 3 Gy. After a median follow-up of 12.2 months, local recurrence was observed in one patient with melanoma in situ. Apart from one grade 4 cataract, no other > grade 2 late toxicity was documented. ConclusionsHDR-BT with 3D-printer-based molds for facial skin cancer is a well-tolerated and safe treatment option for elderly, frail patients not eligible for radical surgery or definitive EBRT due to functional inoperability or tumor location.
引用
收藏
页码:43 / 43
页数:1
相关论文
共 50 条
  • [21] Clinical Assessment of Customized 3D-Printed Wrist Orthoses
    Fang, Jing-Jing
    Lin, Cheng-Li
    Tsai, Jen-Yu
    Lin, Ruey-Mo
    APPLIED SCIENCES-BASEL, 2022, 12 (22):
  • [22] Clinical outcomes of abbreviated high dose-rate brachytherapy in locally advanced cervical cancer: lessons from the COVID pandemic for high dose-rate fractionation
    Chopra, Supriya
    Samanta, Asesh
    Nagar, Arunima
    Mittal, Prachi
    Gupta, Ankita
    Mulani, Jaahid
    Jain, Jeevanshu
    Kohle, Satish
    Ghadi, Yogesh
    Rath, Sushmita
    Gulia, Seema
    Ghosh, Jaya
    Gupta, Sudeep
    BRACHYTHERAPY, 2025, 24 (01) : 1 - 10
  • [23] 3D Printed Surface Applicators for High Dose Rate Brachytherapy
    Clarke, Scott
    Yewondwossen, Mammo
    Robar, James
    MEDICAL PHYSICS, 2016, 43 (08) : 4934 - 4935
  • [24] 3D PRINTED, INDIVIDUALLY CUSTOMIZED HIGH-DOSE-RATE BRACHYTHERAPY APPLICATOR FOR TREATMENT OF CHRONIC DIGITAL PSORIASIS
    Taggar, Amandeep
    Martell, Kevin
    Barnes, Elizabeth
    Ahmed, Bilal
    Paudel, Moti
    Ravi, Ananth
    RADIOTHERAPY AND ONCOLOGY, 2019, 139 : S73 - S73
  • [25] High dose-rate brachytherapy for elderly patients with uterine cervical cancer
    Chen, SW
    Liang, JA
    Yang, SN
    Lin, FJ
    JAPANESE JOURNAL OF CLINICAL ONCOLOGY, 2003, 33 (05) : 221 - 228
  • [26] HIGH DOSE-RATE INTRACAVITARY BRACHYTHERAPY IN ELDERLY WOMEN WITH CERVICAL CANCER
    Melo, M.
    Novaes, P.
    Balloni, H.
    Teixeira, G.
    Castro, D.
    Salvajoli, J. V.
    RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S186 - S187
  • [27] High Dose-rate Intracavitary Brachytherapy in Elderly Patients with Cervical Cancer
    Balloni, H.
    Melo, M. D.
    Novaes, P. E. R. S.
    Salvajoli, J. V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S374 - S374
  • [28] High dose-rate endoluminal brachytherapy for primary and recurrent esophageal cancer
    Nicolay, Nils H.
    Rademacher, Johanna
    Oelmann-Avendano, Jan
    Debus, Juergen
    Huber, Peter E.
    Lindel, Katja
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (07) : 458 - 466
  • [29] Clinical Evaluation of Dosimetric Impact of Applicator Displacements On 3D Gynecological High Dose-Rate Brachytherapy Treatments
    Jayarathna, S.
    Hoover, A.
    Clarke, J.
    Badkul, R.
    MEDICAL PHYSICS, 2022, 49 (06) : E816 - E816
  • [30] Characterization and Validation of 3D Printed High Dose Rate Brachytherapy Applicators
    Wiles, A.
    Pokhrel, S.
    Knewtson, T.
    Jia, Y.
    Goldbaum, D.
    Ballo, M.
    Izaguirre, E. W.
    MEDICAL PHYSICS, 2018, 45 (06) : E354 - E355