Comparison of high-risk HPV detection by the AmpFire® HPV Screening 16/18/HR technique (Atila Biosystems) and the hybrid capture 2 test (Qiagen)

被引:0
|
作者
Koussouri, Anais [1 ,2 ]
Baraquin, Alice [1 ,2 ]
Desmarets, Maxime [3 ,4 ]
Diallo, Kadiatou [3 ]
Puget, Line [1 ,5 ]
Lepiller, Quentin [1 ,5 ,6 ]
Pretet, Jean-Luc [1 ,2 ,6 ]
机构
[1] CHU Besancon, Ctr Natl Reference Papillomavirus, F-25000 Besancon, France
[2] CHU Besancon, Lab Biol Cellulaire, F-25000 Besancon, France
[3] CHU Besancon, Inserm, CIC1431, Besancon, France
[4] Univ Franche Comte, Etab Francais Sang, Inserm, UMR 1098,Right, Besancon, France
[5] CHU Besancon, Lab Virol, 3 Blvd Fleming 25 030, F-25000 Besancon, France
[6] Univ Franche Comte, EA3181, LabEx LipSTIC ANR 11 LABX 0021, F-25000 Besancon, France
关键词
HPV; Hybrid capture 2 test; Ampfire test;
D O I
10.1007/s11033-023-08939-8
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
BackgroundDetection of high-risk human papillomaviruses (hrHPV) is widely used at the first line of cervical cancer screening, requiring rigorous validation of the clinical performance of commercial kits designed for this indication.MethodsPerformance of the AmpFire HPV Screening 16/18/HR test (AF, Atila Biosystems) and the Hybrid Capture 2 test (HC2, Qiagen) for detecting hrHPV was cross-compared in 200 cervical samples in our institution.ResultsThe global percentage of agreement between the 2 techniques was 95.0% (95%CI 92-98%) with a Cohen's kappa coefficient of 0.85 (95%CI 0.75-0.94). Ten samples showed discordant results between the 2 techniques in both directions (5 HC2+/AF- and 5 HC2-/AF+). Among possible explanations for these discrepancies was the detection of HPV66 and HPV53 genotypes in two samples, since these genotypes are targeted by the Ampfire test but not by the HC2 test, as well as intrinsic differences in analytical performance to target specific genotypes.ConclusionsA high level of agreement was observed between the two techniques, which encourages further testing in order to definitively validate the use of the Ampfire kit for primary cervical cancer screening.
引用
收藏
页数:5
相关论文
共 50 条
  • [31] A Rapid, Sensitive and Type-Specific Detection of High-Risk HPV-16 and HPV-18
    Sanjay Gupte
    Sreeja Parthasarathy
    Preeti Arora
    Sharvari Ozalkar
    Shweta Jangam
    Ketaki Rajwade
    Pradnya Nikam
    Sarjan Shah
    The Journal of Obstetrics and Gynecology of India, 2023, 73 : 440 - 444
  • [32] The 16, 18, and 45 HPV infection in high grade squamous cervical lesions in primary hr-HPV test screening program
    Chiappetta, C.
    Lendaro, E.
    Cacciotti, J.
    Zaralli, R.
    Puggioni, C.
    Migliore, G.
    Petrozza, V.
    Della Rocca, C.
    Di Cristofano, C.
    EUROPEAN JOURNAL OF GYNAECOLOGICAL ONCOLOGY, 2015, 36 (06) : 722 - 725
  • [33] Test performance comparison of inform HPV and hybrid capture 2 high-risk HPV DNA tests using the SurePath liquid-based pap test as the collection method
    Davis-Devine, S
    Day, SJ
    Freund, GG
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2005, 124 (01) : 24 - 30
  • [34] Comparison of clinical performances among Roche Cobas HPV, RFMP HPV PapilloTyper and Hybrid Capture 2 assays for detection of high-risk types of human papillomavirus
    Yu, Shinae
    Kwon, Min-Jung
    Lee, Eun Hee
    Park, Hyosoon
    Woo, Hee-Yeon
    JOURNAL OF MEDICAL VIROLOGY, 2015, 87 (09) : 1587 - 1593
  • [35] Comparison of the Abbott RealTime High-Risk Human Papillomavirus (HPV), Roche Cobas HPV, and Hybrid Capture 2 Assays to Direct Sequencing and Genotyping of HPV DNA
    Park, Yongjung
    Lee, Eunhee
    Choi, Jonghyeon
    Jeong, Seri
    Kim, Hyon-Suk
    JOURNAL OF CLINICAL MICROBIOLOGY, 2012, 50 (07) : 2359 - 2365
  • [36] Comparison of the PANArray HPV Genotyping Chip Test with the Cobas 4800 HPV and Hybrid Capture 2 Tests for Detection of HPV in ASCUS Women
    Ki, Eun Young
    Lee, Yoon Kyung
    Lee, Ahwon
    Park, Jong Sup
    YONSEI MEDICAL JOURNAL, 2018, 59 (05) : 662 - 668
  • [37] Utilization of PAX1 methylation test for cervical cancer screening of non-HPV16/18 high-risk HPV infection in women
    Yang, Li
    Tao, Hong
    Lin, Beibei
    He, Xiaoli
    Chen, Yibo
    Fan, Xing
    FUTURE ONCOLOGY, 2023, 19 (28) : 1917 - 1927
  • [38] Comparing the Cervista HPV HR Test and Hybrid Capture 2 Assay in a Dutch Screening Population: Improved Specificity of the Cervista HPV HR Test by Changing the Cut-Off
    Boers, Aniek
    Slagter-Menkema, Lorian
    van Hemel, Bettien M.
    Belinson, Jerome L.
    Ruitenbeek, Teus
    Buikema, Henk J.
    Klip, Harry
    Ghyssaert, Hilde
    van der Zee, Ate G. J.
    de Bock, Geertruida H.
    Wisman, G. Bea A.
    Schuuring, Ed
    PLOS ONE, 2014, 9 (07):
  • [39] High risk HPV detection: A split sample comparison of hybrid capture and in situ hybridization
    Schiller, CL
    Hy, JM
    Escobar, MT
    Kaul, KL
    Watkin, WG
    Sturgis, CD
    LABORATORY INVESTIGATION, 2003, 83 (01) : 80A - 80A
  • [40] High risk HPV detection: A split sample comparison of hybrid capture and in situ hybridization
    Schiller, CL
    Hy, JM
    Escobar, MT
    Kaul, KL
    Watkin, WG
    Sturgis, CD
    MODERN PATHOLOGY, 2003, 16 (01) : 80A - 80A