Field study of meeting thermal needs of occupants in old residential buildings in low-temperature environments using personalized local heating

被引:6
|
作者
Yang, Zhen [1 ,2 ]
Zhang, Weirong [1 ,2 ]
Liu, Hongkai [3 ]
Zhang, Weijia [1 ]
Qin, Mingyuan [4 ]
机构
[1] Beijing Univ Technol, Key Lab Green Built Environm & Energy Efficient Te, Beijing 100124, Peoples R China
[2] Beijing Univ Technol, Chongqing Res Inst, Chongqing 401121, Peoples R China
[3] Jilin Univ, Coll Automot Engn, Changchun 130025, Peoples R China
[4] Univ Malaya, Fac Engn, Kuala Lumpur 50603, Malaysia
关键词
Local heating; Thermal comfort; Conditioning environment; Personal comfort system; Low -temperature environment; COMFORT; CHAIR; IMPROVEMENT; SENSATION; SYSTEMS; CLIMATE;
D O I
10.1016/j.buildenv.2023.111004
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The outdated structures and heating devices in old residential buildings can no longer functionally meet the thermal needs of users and require reasonable supplementary measures to meet the demand. Personalized local heating, owing to its thermal comfort and energy-saving performance, is a good solution for addressing the thermal needs of occupants. The objective of this study was to examine the influence of personalized local heating on the thermal comfort of occupants in old residential buildings under low-temperature heating. A field study was conducted with 16 participants in typical old residential buildings under different conditions from January to February 2023. The findings revealed that all personalized local heating methods could increase the overall thermal sensation of participants at background temperatures of 16 degrees C and 19 degrees C, but only a few of them were effective in enhancing the participants' overall thermal comfort. Regardless of the chosen localized heating method, the participants' thermal acceptance vote varied over time. When using localized heating, there were differences in the body parts selected for heating among participants at 16 degrees C and 19 degrees C. The analysis showed that the corrective power of heating devices for human thermal comfort is related to the background environ-ment temperature, with stronger corrective power shown at lower temperatures. Furthermore, as long as the problem of uneven local heating was effectively resolved, radiant devices were the preferred environmental conditioning devices. This study provides important guidance, both for improving thermal comfort in old resi-dential buildings and for expanding the application of personalized local heating.
引用
收藏
页数:13
相关论文
共 39 条
  • [31] Modeling of a Low-Temperature Geothermal Field Using UAV-based TIR and RGB Images: A Case Study of Kocabaşlar Geothermal Field, Northwestern Türkiye
    Yucel, Deniz Sanliyuksel
    Yuecel, Mehmet Ali
    TURKIYE JEOLOJI BULTENI-GEOLOGICAL BULLETIN OF TURKEY, 2024, 67 (01): : 115 - 136
  • [32] Experimental study on condensation-free radiant cooling panel with low-temperature for local cooling in vehicles-Part 2: Demonstration with passengers for thermal comfort analysis
    Wong, Suet Man
    Gopi, Gineesh
    Kim, Jung Kyung
    Lee, Dongchan
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2025, 160
  • [33] Hydrogen positions and thermal expansion in lizardite-1T from Elba: A low-temperature study using Rietveld refinement of neutron diffraction data
    Gregorkiewitz, M
    Lebech, B
    Mellini, M
    Viti, C
    AMERICAN MINERALOGIST, 1996, 81 (9-10) : 1111 - 1116
  • [34] Temperature-dependent Raman study and determination of anisotropy ratio and in-plane thermal conductivity of low-temperature CVD-grown PdSe2 using unpolarized laser excitation
    Jena, Tadasha
    Hossain, Md Tarik
    Giri, P. K.
    JOURNAL OF MATERIALS CHEMISTRY C, 2021, 9 (46) : 16693 - 16708
  • [35] Numerical study of natural convection of fluid with temperature-dependent viscosity inside a porous cube under non-uniform heating using local thermal non-equilibrium approach
    Astanina M.S.
    Sheremet M.A.
    International Journal of Thermofluids, 2023, 17
  • [36] STUDY OF NEW THIRXSI2-X (0 LESS-THAN-OR-EQUAL-TO X LESS-THAN-OR-EQUAL-TO 1) SUPERCONDUCTORS USING SPECIFIC LOW-TEMPERATURE HEATING AND XPS SPECTROSCOPY
    CHEVALIER, B
    ZHONG, WX
    BUFFAT, B
    ETOURNEAU, J
    HAGENMULLER, P
    LEJAY, P
    PORTE, L
    DUC, TM
    BESNUS, MJ
    KAPPLER, JP
    MATERIALS RESEARCH BULLETIN, 1986, 21 (02) : 183 - 194
  • [37] Feasibility study of low-temperature operable electric power supply for CubeSats using passive thermal control with VO2-based solid-solid phase change material
    Yamagata, Masaki R.
    Wakita, Yurina
    Tsuruda, Yoshihiro
    Miyata, Kikuko
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2023, 37
  • [38] Study on the low-temperature properties of pyrochlores Gd2Hf2O7 and Gd2Zr2O7, using crystal-field theory
    Biswas, Aksar Ali
    Jana, Yatramohan
    SOLID STATE PHYSICS: PROCEEDINGS OF THE 55TH DAE SOLID STATE PHYSICS SYMPOSIUM 2010, PTS A AND B, 2011, 1349 : 1121 - 1122
  • [39] Synthetical study on the difference and reason for the pore structure of the No. 3 coal reservoir from the southern Qinshui Basin, China, using mercury intrusion porosimetry, low-temperature N2 adsorption, low field nuclear magnetic resonance, and nuclear magnetic resonance cryoporometry
    Liu, Huihu
    Farid, Ibrahim Issa
    Sang, Shuxun
    Shang, Jianhua
    Wu, Haiyan
    Xu, Hongjie
    Zhang, Pingshong
    Liu, Qimeng
    ENERGY REPORTS, 2020, 6 : 1876 - 1887