Detection and quantification of JAK2V617F copy number by droplet digital PCR versus real-time PCR

被引:0
|
作者
Wu, Sanyun [1 ]
Li, Yixuan [1 ]
Huang, Ruiying [1 ]
Li, Ting [1 ]
Yu, Yalan [1 ]
Luo, Ping [1 ]
Zuo, Xuelan [1 ]
He, Li [1 ]
机构
[1] Wuhan Univ, Dept Hematol, Zhongnan Hosp, Donghu Rd 169, Wuhan, Peoples R China
关键词
Myeloproliferative neoplasm; Droplet digital PCR; Real-time PCR; Next-generation sequencing;
D O I
10.1007/s00277-023-05544-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Myeloproliferative neoplasm (MPN) usually has an adverse prognosis, progressing to acute leukemia or splanchnic vein thromboses (SVTs). Therefore, early diagnosis and intervention are significantly important. Clinically, the burden of JAK2V617F is a vital diagnostic basis, which can be detected during the early stage of MPN. Thus, an accurate and rapid detective technique is urgently required. In recent years, real-time quantitative PCR (qPCR) has primarily been applied to detect the copies of JAK2V617F, whereas droplet digital PCR (ddPCR), a novel and promising detective tool, can conduct precise and repeatable quantification of nucleic acid copies without relying on the standard curve. In our study, both qPCR and ddPCR are used to evaluate the mutation burden of JAK2V617F in a series of gradient diluted standards and clinical JAK2V617F-positive MPN patients' bone marrow samples collected, while using next-generation sequencing technology (NGS) as a contrast. With the help of statistical methods, our study concluded that ddPCR had a better performance in accuracy, sensitivity, and stability, especially in a low burden. Regarding the accuracy, ddPCR showed a better linearity (Pearson R-2 = 0.9926; P < 0.0001) than qPCR (Pearson R-2 = 0.9772; P < 0.0001). What is more, ddPCR showed lower intra-assay and inter-assay CVs and the limit of detection (LOD) for the series of diluted standards than qPCR, demonstrating better stability and lower LOD. In a nutshell, ddPCR is a more promising technique for the detection and quantification of JAK2V617F.
引用
收藏
页码:421 / 426
页数:6
相关论文
共 50 条
  • [21] Sensitive and accurate quantification of JAK2 V617F mutation in chronic myeloproliferative neoplasms by droplet digital PCR
    Miguel Waterhouse
    Marie Follo
    Dietmar Pfeifer
    Nikolas von Bubnoff
    Justus Duyster
    Hartmut Bertz
    Jürgen Finke
    Annals of Hematology, 2016, 95 : 739 - 744
  • [22] Sensitive and accurate quantification of JAK2 V617F mutation in chronic myeloproliferative neoplasms by droplet digital PCR
    Waterhouse, Miguel
    Follo, Marie
    Pfeifer, Dietmar
    von Bubnoff, Nikolas
    Duyster, Justus
    Bertz, Hartmut
    Finke, Juergen
    ANNALS OF HEMATOLOGY, 2016, 95 (05) : 739 - 744
  • [23] Method optimization for the detection of chimerism by real-time PCR and droplet digital PCR
    Lambrescu, I. M.
    Ionescu, V. S.
    Gaina, G.
    Popa, A.
    Niculite, C.
    Cismasiu, V. B.
    ANNALS OF ONCOLOGY, 2021, 32 : S1358 - S1358
  • [24] Comparison of Droplet Digital PCR to Real-Time PCR for Quantitative Detection of Cytomegalovirus
    Hayden, R. T.
    Gu, Z.
    Ingersoll, J.
    Abdul-Ali, D.
    Shi, L.
    Pounds, S.
    Caliendo, A. M.
    JOURNAL OF CLINICAL MICROBIOLOGY, 2013, 51 (02) : 540 - 546
  • [25] Detection and Quantification of Klebsiella pneumoniae in Fecal Samples Using Digital Droplet PCR in Comparison with Real-Time PCR
    Feng, Junxia
    Cui, Xiaohu
    Du, Bing
    Zhao, Hanqing
    Feng, Yanling
    Cui, Jinghua
    Yan, Chao
    Gan, Lin
    Fan, Zheng
    Fu, Tongtong
    Xu, Ziying
    Yu, Zihui
    Zhang, Rui
    Du, Shuheng
    Tian, Ziyan
    Zhang, Qun
    Xue, Guanhua
    Yuan, Jing
    MICROBIOLOGY SPECTRUM, 2023, 11 (04):
  • [26] Development of a quantitative real-time PCR assay for the detection of the JAK2 V617F mutation in myeloproliferative disorders
    Wolstencroft, E
    Hanlon, K
    Harries, L
    Sternberg, A
    Ellard, S
    BRITISH JOURNAL OF HAEMATOLOGY, 2006, 133 : 77 - 77
  • [27] Real-time PCR increases the detection rate of the JAK2 V617F mutation in chronic myeloproliferative diseases
    Zach, O.
    Foedermayr, M.
    Kessler, B.
    Hauser, H.
    Krieger, O.
    Kasparu, H.
    Girschikofsky, M.
    Preining, J.
    Krieger, D.
    HAEMATOLOGICA-THE HEMATOLOGY JOURNAL, 2007, 92 : 545 - 546
  • [28] DROPLET DIGITAL PCR: GREATER PRECISION AND ROBUSTNESS THAN QUANTITATIVE REAL TIME PCR IN THE MEASUREMENT OF LOW-ALLELE JAK2 V617F FREQUENCIES
    Gesullo, F.
    Mannarelli, C.
    Maccari, C.
    Lagrotteria, A.
    Vannucchi, A. M.
    Guglielmelli, P.
    HAEMATOLOGICA, 2022, 107 : 41 - 41
  • [29] Quantification of Plasmid Copy Number with Single Colour Droplet Digital PCR
    Plotka, Magdalena
    Wozniak, Mateusz
    Kaczorowski, Tadeusz
    PLOS ONE, 2017, 12 (01):
  • [30] Comparison of droplet digital PCR to real-time PCR for quantification of hepatitis B virus DNA
    Tang, Hui
    Cai, Qingchun
    Li, Hu
    Hu, Peng
    BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 2016, 80 (11) : 2159 - 2164