A Study on Mechanical Performance of an Innovative Modular Steel Building Connection with Cross-Shaped Plug-In Connector

被引:4
|
作者
Ma, Hongwei [1 ]
Huang, Ziming [1 ]
Song, Xiongbin [2 ]
Ling, Yuhong [1 ,3 ]
机构
[1] South China Univ Technol, Sch Civil Engn & Transportat, Guangzhou 510641, Peoples R China
[2] Guangzhou Acad Bldg Sci Grp Co Ltd, Guangzhou 510440, Peoples R China
[3] South China Univ Technol, State Key Lab Subtrop Bldg Sci, Guangzhou 510640, Peoples R China
关键词
modular steel building; inter-module connection; cold-formed thin-walled steel structure; mechanical performance; panel zone shear resistance; initial rotational stiffness; SEISMIC BEHAVIOR;
D O I
10.3390/buildings13092382
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Modular steel buildings show high assembly degree and fast installation speed. The inter-module connection (IMC) is one of the key technologies that restrict the robustness of modular steel buildings. An innovative IMC with a cross-shaped plug-in connector is proposed, and the connection consists of end plates of columns, the cross-shaped plug-in connector, bolts, cover plates, and one-side bolts. The proposed IMC is easily constructed, and the cross-shaped plug-in connector can improve the shear resistance of the core area. The mechanical model of the proposed IMC is presented, and the panel zone volume modified factor and initial rotational stiffness modified factor are proposed for calculating the shear capacity of the panel zone and the initial rotational stiffness. Numerical simulation was conducted considering the influences of axial compression ratios, sections of beams and columns, and the thickness of the tenon plate of the connector. The bearing capacity of the proposed IMC was analyzed, and the values of the two factors mentioned above were calculated, and their regression formulas are presented. The results show that the sections of beams and columns and the axial compression ratios show great influences on the bearing capacity of the proposed IMC, while the thickness of the tenon of the cross-shaped plug-in connector shows almost no effect. In addition, the sections of beams and columns show great influences on the shear capacity of the panel zone, as well as the initial rotational stiffness of the proposed IMC, while the thickness of the tenon of the cross-shaped plug-in connector and the axial compression ratios show little effect and almost no effect, respectively. Furthermore, the bending moment limit of the beam end of the proposed IMC is suggested to be 0.6 times the resistance bending moment, and the proposed IMC is considered to be a rigid connection or inclined to a rigid connection The proposed IMC has good mechanical performance, and design recommendations are presented.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] Experimental study and parametric analysis on seismic behavior of solid-web steel reinforced concrete cross-shaped column
    Zhang, Bo
    Fang, Lin
    Jin, Guofang
    Li, Kaiwen
    Tongji Daxue Xuebao/Journal of Tongji University, 2015, 43 (09): : 1301 - 1307
  • [42] Experimental and numerical study on the hysteretic behavior of a hybrid timber buckling-restrained brace with a cross-shaped steel core
    Luo, Lie
    Sun, Xiaofeng
    Song, Xiaobin
    Ou, Zhaohui
    Zhang, Lin
    SOIL DYNAMICS AND EARTHQUAKE ENGINEERING, 2022, 162
  • [43] Experimental study on seismic performance of cross-shaped half-tenon joint reinforced by angle in traditional dwellings
    Xue J.
    Ren G.
    Zhang J.
    Xu D.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2021, 42 (01): : 103 - 112
  • [44] Experimental study and finite element analysis on seismic behavior of solid-web steel reinforced concrete cross-shaped and L-shaped columns
    Liu Z.
    Du Z.
    Xue J.
    Zhou C.
    Ren R.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 (04): : 104 - 115
  • [45] Experimental study on seismic cyclic behavior of an innovative blind bolted connection joint between modules in modular steel frame
    Liu, Ziliang
    Wang, Yan
    Zhang, Zhonghao
    Wu, Wenshuang
    STRUCTURES, 2023, 52 : 158 - 174
  • [46] Experimental and analytical study of square tubed concrete-encased cross-shaped steel (TCCS) columns under axial compression
    Lu, Shiwei
    Wang, Jizhong
    Yang, Junlong
    Wang, Licheng
    ENGINEERING STRUCTURES, 2023, 277
  • [47] Experimental study on seismic behavior of cross-shaped concrete- filled steel tubular columns under diagonal cyclic loading
    Zheng Y.
    Lai P.
    Wang Z.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2020, 41 (10): : 58 - 66
  • [48] Study on the Bending Performance of Connection Joints in a New Type of Modular Steel Structure Emergency Repair Pier
    Liu, Xingwang
    Sun, Wenya
    Li, Hongtao
    Liu, Yang
    Xu, Liwen
    Liu, Fan
    BUILDINGS, 2025, 15 (06)
  • [49] Experimental study on axial mechanical performance of steel pipe-to-sleeve grouted connection
    Wu L.
    Su Y.
    Chen H.
    Yu H.
    Li Y.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2019, 40 (11): : 191 - 199
  • [50] Mechanical performance study of a novel modular gymnasium inner sleeve all-bolt cross connection joint - Part II: Parametric study and design recommendations
    Zhong, Chang-jun
    Hui, Ze
    Zhang, Zhi-jie
    Li, Hu-yang
    Huang, Yong-qi
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2025, 226