Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method to quantify antiretroviral drug concentrations in human plasma for therapeutic monitoring

被引:0
|
作者
West III, Raymond E. [1 ]
Oberly, Patrick J. [1 ]
Riddler, Sharon A. [2 ]
Nolin, Thomas D. [1 ]
Devanathan, Aaron S. [1 ,3 ]
机构
[1] Univ Pittsburgh, Ctr Clin Pharmaceut Sci, Sch Pharm, Dept Pharm & Therapeut, Pittsburgh, PA USA
[2] Univ Pittsburgh Sch Med, Dept Med, Pittsburgh, PA USA
[3] Univ Pittsburgh Sch Pharm, Sch Pharm, 208 Salk Pavil,335 Sutherland Dr, Pittsburgh, PA 15261 USA
关键词
Antiretrovirals; Concentrations; HIV; UPLC-MS/MS; Therapeutic drug monitoring; Clinical pharmacology; LC-MS/MS METHOD;
D O I
10.1016/j.jpba.2023.115932
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Antiretroviral therapy (ART) is highly effective for the treatment of HIV-1 infection. ART previously consisted of concomitant administration of many drugs, multiple times per day. Currently, ART generally consists of two- or three-drug regimens once daily as fixed-dose combinations. Drug monitoring may be necessary to ensure adequate concentrations are achieved in the plasma over the dosing interval and prevent further HIV resistance formation. Additionally, nonadherence remains an issue, highlighting the need to ensure sufficient ART exposure. Towards this effort, we developed and validated a highly selective ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method for the simultaneous quantification of a panel of nine antiretrovirals: abacavir, bictegravir, cabotegravir, dolutegravir, doravirine, emtricitabine, lamivudine, raltegravir, and tenofovir in human plasma. Using only 50 mu L of plasma, a simple protein precipitation with acetonitrile with internal standards followed by reconstitution in 50 uL (high) or 400 uL (low) was performed. Analyte separation was achieved using a multistep UPLC gradient mixture of (A: 0.1% formic acid in water and B: acetonitrile) and a Waters CORTECS T3 (2.1 x100 mm) column. The method was comprehensively validated according to the United States Food and Drug Administration Bioanalytical Guidelines over two clinically relevant ranges (1-250 ng/mL and 100-5000 ng/mL) with excellent linearity (R-2 > 0.99 for all). The assay run time was 7.5 min. This method achieves acceptable performance of trueness (89.7-104.1%), repeatability, and precision (CV <15%), and allows for simultaneous quantification of guideline-recommended ART regimens. This method can be utilized for the therapeutic monitoring of antiretrovirals in human plasma.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method for quantifying lenacapavir plasma concentrations: Application to therapeutic monitoring
    West III, Raymond E.
    Oberly, Patrick J.
    Riddler, Sharon A.
    Nolin, Thomas D.
    Devanathan, Aaron S.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2023, 1230
  • [2] Development, validation, and application of an ultra-high performance liquid chromatography-tandem mass spectrometry method for the estimation of Ropanicant in human plasma and urine
    Nirogi, Ramakrishna
    Kalaikadhiban, Ilayaraja
    Rayapati, Lakshmi Prasanna
    Pantangi, Hanumanth Rao
    Chunduru, Prathyusha
    Jetta, Satish
    Jubre, Avinash
    Mohammed, Abdul Rasheed
    JOURNAL OF CHROMATOGRAPHY OPEN, 2023, 3
  • [3] Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method to measure creatinine in human urine
    Fraselle, S.
    De Cremer, K.
    Coucke, W.
    Glorieux, G.
    Vanmassenhove, J.
    Schepers, E.
    Neirynck, N.
    Van Overmeire, I.
    Van Loco, J.
    Van Biesen, W.
    Vanholder, R.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 988 : 88 - 97
  • [4] Quantification of typical antipsychotics in human plasma by ultra-high performance liquid chromatography tandem mass spectrometry for therapeutic drug monitoring
    Gradinaru, Julieta
    Vullioud, Astrid
    Eap, Chin B.
    Ansermot, Nicolas
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 88 : 36 - 44
  • [5] Development and validation of an ultra performance liquid chromatography-tandem mass spectrometry method for the quantification of daptomycin in human plasma
    Bazoti, Fotini N.
    Gikas, Evangelos
    Skoutelis, Athanasios
    Tsarbopoulos, Anthony
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 56 (01) : 78 - 85
  • [6] Development and Validation of a Sensitive Liquid Chromatography-Tandem Mass Spectrometry Method for Therapeutic Drug Monitoring of Ceftolozane and Tazobactam in Human Plasma Microsamples
    Conti, Matteo
    Giorgi, Beatrice
    Gatti, Milo
    Viale, Pierluigi
    Pea, Federico
    THERAPEUTIC DRUG MONITORING, 2024, 46 (06) : 756 - 763
  • [7] Therapeutic drug monitoring of clozapine and norclozapine using a multidrug ultra-high performance liquid chromatography-tandem mass spectrometric method
    Patteet, Lisbeth
    Vermeulen, Zarha
    Maudens, Kristof E.
    Sabbe, Bernard
    Morrens, Manuel
    Neels, Hugo
    CLINICAL TOXICOLOGY, 2014, 52 (04) : 330 - 330
  • [8] An ultra high performance liquid chromatography-tandem mass spectrometry method for the quantification of linagliptin in human plasma
    Nannapaneni, Nagaraj Kumar
    Jalalpure, Sunil S.
    Muppavarapu, Rajendraprasad
    Sirigiri, Sunil Kumar
    RSC ADVANCES, 2016, 6 (71): : 66756 - 66766
  • [9] Development and validation of a high performance liquid chromatography-tandem mass spectrometry for the determination of etodolac in human plasma
    Lee, Hyun-Soo
    Kang, Il-Mo
    Lee, Heon-Woo
    Seo, Ji-Hyung
    Ryu, Ju-Hee
    Choi, Sang-Jun
    Lee, Myung-Jae
    Jeong, Seo-Young
    Cho, Young-Wuk
    Lee, Kyung-Tae
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2008, 863 (01): : 158 - 162
  • [10] Recent development in application of high performance liquid chromatography-tandem mass spectrometry in therapeutic drug monitoring of immunosuppressants
    Yang, Zheng
    Wang, Sihe
    JOURNAL OF IMMUNOLOGICAL METHODS, 2008, 336 (02) : 98 - 103