Vibration Control of a Two-Story Base-Isolated Building using a New Tuned Mass Multi-Sliding Friction Damper

被引:2
|
作者
Amjadian, Mohsen [1 ]
Haider, Syed Muhammad Bilal [1 ]
机构
[1] Univ Texas Rio Grande Valley, Dept Civil Engn, Edinburg, TX 78539 USA
关键词
Vibration control; Tuned mass damper; Friction; Energy dissipation; Seismic isolation;
D O I
10.1117/12.2661140
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper studies the use of a new Tuned Mass Multi-Sliding Friction Damper (TMMSFD) to increase the damping capacity of seismic isolators installed on a two-story base-isolated building to limit their lateral deformations. The proposed TMMSFD consists of a set of several masses that are laterally attached to the superstructure floor through linear springs. These masses are placed on top of each other one by one and are allowed to slide with respect to each other during the earthquake. The bottom mass that carries the weight of upper masses is in contact with the superstructure floor. The damping of system is supplied by the friction generated along the sliding friction surfaces. The TMMSFD has a low cost of installation, operation, and maintenance compared to common TMDs that use viscous fluid dampers for energy dissipation. The mechanical model of TMMSFD is installed on the numerical model of a two-story base-isolated building equipped with elastomeric rubber bearings in order to evaluate its performance in limiting the displacement of base floor. These models are created by the OpenSEESPy package which is a Python 3 interpreter of OpenSEES. A parametric study is performed to obtain the optimum design parameters of the TMMSFD including its total mass, frequency, and static friction coefficients of the siding surfaces for energy dissipation. The results of time-history analysis of numerical model show that the TMMSFD is capable of limiting the displacement of base floor with a little amount of friction implying its potential as a cost-effective tool for seismic protection.
引用
收藏
页数:10
相关论文
共 28 条
  • [1] Optimal Design of Nontraditional Tuned Mass Damper for Base-Isolated Building
    Li, Dawei
    Ikago, Kohju
    JOURNAL OF EARTHQUAKE ENGINEERING, 2023, 27 (10) : 2841 - 2862
  • [2] Seismic response control of base-isolated buildings using tuned mass damper
    Stanikzai, Mohammad Hamayoun
    Elias, Said
    Matsagar, Vasant A.
    Jain, Arvind K.
    AUSTRALIAN JOURNAL OF STRUCTURAL ENGINEERING, 2020, 21 (01) : 310 - 321
  • [3] Vibration control of multi-story building structure by hybrid control using tuned liquid damper and active mass damper
    Shin, Ji-Hwan
    Kwak, Moon K.
    Kim, Soo-Min
    Baek, Kwang-Hyun
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2020, 34 (12) : 5005 - 5015
  • [4] Vibration control of multi-story building structure by hybrid control using tuned liquid damper and active mass damper
    Ji-Hwan Shin
    Moon K. Kwak
    Soo-Min Kim
    Kwang-Hyun Baek
    Journal of Mechanical Science and Technology, 2020, 34 : 5005 - 5015
  • [5] Assessment of the tuned mass damper inerter for seismic response control of base-isolated structures
    Masnata, Chiara
    Di Matteo, Alberto
    Adam, Christoph
    Pirrotta, Antonina
    STRUCTURAL CONTROL & HEALTH MONITORING, 2021, 28 (02):
  • [6] A Novel Approach for Vibration Control of Base-Isolated Structures Under Seismic Load Using a Tuned Mass Damper-Clutching Inerter
    Kiran, K. K.
    Al-Osta, Mohammed A.
    Ahmad, Shamsad
    Bahraq, Ashraf A.
    JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2024, 12 (07) : 8737 - 8757
  • [7] Vibration control of structure by top base isolated storey as tuned mass damper
    Manchalwar A.
    Bakre S.V.
    Intl. J. Dyn. Cont., 2020, 3 (963-972): : 963 - 972
  • [8] Seismic response control of multi-story base-isolated buildings using a smart electromagnetic friction damper with smooth hysteretic behavior
    Amjadian, Mohsen
    Agrawal, Anil K.
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 130 : 409 - 432
  • [9] Semi-Active Fuzzy Control of Tuned Mass Damper to Reduce Base-Isolated Building Response under Harmonic Excitation
    Djedoui, Nassim
    Ounis, Abdelhafid
    Mahdi, Abdeddaim
    Zahrai, Seyed Mehdi
    JORDAN JOURNAL OF CIVIL ENGINEERING, 2018, 12 (03) : 435 - 448
  • [10] Hybrid system of base-isolated structures with tuned tandem mass damper-inerters considering internal friction
    Li, Xin
    Wang, Zhihao
    Pan, Hang
    Cao, Liyuan
    Li, Chunxiang
    JOURNAL OF BUILDING ENGINEERING, 2025, 101