Hot Mail: Temperature Exposure during Mail Return of an Immunochemical Fecal Occult Blood Test

被引:1
|
作者
Laven-Law, Geraldine [1 ,2 ,4 ]
Bastin, Dawn [1 ,2 ]
Fraser, Robert J. L. [2 ,3 ]
Cock, Charles [2 ,3 ]
Young, Graeme P. [1 ,2 ]
Winter, Jean M. [1 ,2 ]
Symonds, Erin L. [1 ,2 ,3 ]
机构
[1] Flinders Hlth & Med Res Inst, Canc Res, Bedford Pk, SA, Australia
[2] Flinders Univ S Australia, Coll Med & Publ Hlth, Bedford Pk, SA, Australia
[3] Flinders Med Ctr, Dept Gastroenterol & Hepatol, Adelaide, SA, Australia
[4] Flinders Hlth & Med Res Inst, Flinders Ctr Innovat Canc, Flinders Med Ctr, Canc Res, Level 3,Flinders Dr, Bedford Pk, SA 5042, Australia
关键词
HEMOGLOBIN; PERFORMANCE; BUFFER; PROGRAM; TIME; FIT;
D O I
10.1093/clinchem/hvad052
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Background Fecal immunochemical tests (FITs) are widely used for colorectal cancer (CRC) screening; however, high ambient temperatures were found to reduce test accuracy. More recently, proprietary globin stabilizers were added to FIT sample buffers to prevent temperature-associated hemoglobin (Hb) degradation, but their effectiveness remains uncertain. We aimed to determine the impact of high temperature (>30 degrees C) on OC-Sensor FIT Hb concentration with current FITs, characterize FIT temperatures during mail transit, and determine impact of ambient temperature on FIT Hb concentration using data from a CRC screening program. Methods FITs were analyzed for Hb concentration after in vitro incubation at different temperatures. Data loggers packaged alongside FITs measured temperatures during mail transit. Separately, screening program participants completed and mailed FITs to the laboratory for Hb analysis. Regression analyses compared the impact of environmental variables on FIT temperatures and separately on FIT sample Hb concentration. Results In vitro incubation at 30 to 35 degrees C reduced FIT Hb concentration after >4 days. During mail transit, maximum FIT temperature averaged 6.4 degrees C above maximum ambient temperature, but exposure to temperature above 30 degrees C was for less than 24 hours. Screening program data showed no association between FIT Hb concentration and maximum ambient temperatures. Conclusions Although FIT samples are exposed to elevated temperatures during mail transit, this is brief and does not significantly reduce FIT Hb concentration. These data support continuation of CRC screening during warm weather with modern FITs with a stabilizing agent when mail delivery is <= 4 days.
引用
收藏
页码:615 / 626
页数:12
相关论文
共 50 条
  • [21] A Comparison of Immunochemical Fecal Occult Blood Test and Total Colonoscopy in an Asymptomatic Population
    Yoshii, Shinji
    Mabe, Katsuhiro
    Keiko, Watano
    Akakura, Nobuaki
    Kato, Mototsugu
    GASTROENTEROLOGY, 2014, 146 (05) : S545 - S545
  • [22] Quantitative immunochemical fecal occult blood test for diagnosing colorectal neoplasia - In response
    Rozen, Paul
    Levi, Zohar
    Niv, Yaron
    ANNALS OF INTERNAL MEDICINE, 2007, 147 (07) : 523 - 523
  • [23] Quantitative immunochemical fecal occult blood test for neoplasia in colon cancer screening
    Yuan, Si Yi
    Wu, Wei
    Fu, Jing
    Lang, Yi Xuan
    Li, Ji Chi
    Guo, Ye
    Wang, Ya Nan
    Qian, Jia Ming
    Li, Jing Nan
    JOURNAL OF DIGESTIVE DISEASES, 2019, 20 (02) : 78 - 82
  • [24] Colonoscopic evaluation of immunochemical fecal occult blood test for detection of colorectal neoplasia
    Nakama, H
    Yamamoto, M
    Kamijo, N
    Li, T
    Wei, N
    Fattah, ASMA
    Zhang, B
    HEPATO-GASTROENTEROLOGY, 1999, 46 (25) : 228 - 231
  • [25] A comparison of the immunochemical fecal occult blood test and total colonoscopy in the asymptomatic population
    Morikawa, T
    Kato, J
    Yamaji, Y
    Wada, R
    Mitsushima, T
    Shiratori, Y
    GASTROENTEROLOGY, 2005, 129 (02) : 422 - 428
  • [26] IMMUNOCHEMICAL FECAL OCCULT BLOOD TEST AND COLONOSCOPIC SCREENING IN JAPANESE ALCOHOLIC MEN
    Mizukami, T.
    Yokoyama, A.
    Yokoyama, T.
    Matsui, T.
    Maruyama, K.
    ALCOHOLISM-CLINICAL AND EXPERIMENTAL RESEARCH, 2012, 36 : 94A - 94A
  • [27] EVALUATION OF THE SENSITIVITY OF AN IMMUNOCHEMICAL FECAL OCCULT BLOOD-TEST FOR COLORECTAL NEOPLASIA
    YOSHINAGA, M
    MOTOMURA, S
    TAKEDA, H
    YANAGISAWA, Z
    IKEDA, K
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 1995, 90 (07): : 1076 - 1079
  • [28] Enhancing Colorectal Cancer Screening Specificity by Integrating Fecal MicroRNA Signature With Fecal Immunochemical Test and Fecal Occult Blood Test
    Noursina, Ali
    Safari, Farzad
    GASTROENTEROLOGY, 2024, 166 (02) : 358 - 358
  • [29] To test or not to test fecal occult blood
    不详
    LABORATORY MEDICINE, 1997, 28 (08) : 488 - 488
  • [30] Randomized study comparing the test performance of a guaiac-based fecal occult blood test with an immunochemical fecal occult blood test for colorectal cancer screening in a screening population
    van Rossum, Leo
    van Rijn, Anne Floortje
    Laheij, Robert
    Verbeek, Andre L.
    van Oijen, Martijn G.
    Fockens, Paul
    Jansen, Jan B.
    Dekker, Evelien
    GASTROENTEROLOGY, 2008, 134 (04) : A87 - A87