Measuring Anthropomorphism of a New Humanoid Hand-Arm System

被引:2
|
作者
Sinha, Anoop Kumar [1 ,2 ]
Thalmann, Nadia Magnenat [2 ,3 ]
Cai, Yiyu [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, 50 Nanyang Ave, Singapore 639798, Singapore
[2] Nanyang Technol Univ, Inst Media Innovat, XFrontiers Block, Singapore 637553, Singapore
[3] Univ Geneva, MIRALab, Geneva, Switzerland
基金
新加坡国家研究基金会;
关键词
Anthropomorphism; Anthropomorphic score; Robotic hand-arm system; Humanoids; Manipulability analysis; Workspace analysis; LIGHTWEIGHT ROBOT; DESIGN; MODEL; RELIABILITY; KINEMATICS;
D O I
10.1007/s12369-023-00999-x
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Existing perceptional and analytical techniques for quantifying anthropomorphism of robotic hand-arm systems have significant limitations. The former is based on subjective appraisals by human observers, which are prone to biases. The latter frequently disregards the manipulability of the robotic hand-arm system leading to potentially flawed estimation of anthropomorphism. Additionally, prior methodologies have predominantly focused on assessing anthropomorphism of robotic hands while paying scant attention to that of robotic arms. In this paper, we propose an analytical method to quantify the functional anthropomorphism of robotic hand-arm systems. In this method, relative workspace coverage and manipulability of the robot arm and fingers are compared with those of the human arm and fingers. The proposed methodology is then used to quantify functional anthropomorphism of several hand-arm systems, including our new full-scale humanoid robot hand-arm system, the iCub hand-arm system, and robot arms such as Atlas, H20, and Hubo2+/Sophia, as well as robot hands like Shadow, DEXMART, and SEOULTECH. Our new robot hand-arm system has a functional anthropomorphism of 23.31%, while iCub's is 35.96%. Atlas, H20, and Hubo2+/Sophia robot arm have functional anthropomorphism of 24.79%, 12.82%, and 29.64%, respectively, while Shadow, DEXMART, and SEOULTECH robot hands have functional anthropomorphism of 36.96%, 48.91%, and 25.33%, respectively. The proposed method is an effective tool for designers to quantitatively compare the human-likeness of both new and existing robotic hand-arm systems and identify possible improvements in the design. We further conducted a series of kinematic experiments to ascertain the kinematic capabilities of our humanoid robot hand-arm system.
引用
收藏
页码:1341 / 1363
页数:23
相关论文
共 50 条
  • [21] KINEMATIC AND DYNAMIC ANALYSIS OF AN ANTHROPOMORPHIC HAND-ARM SYSTEM
    Dumitru, Ştefan
    Craifaleanu, Andrei
    UPB Scientific Bulletin, Series D: Mechanical Engineering, 2023, 85 (04): : 27 - 42
  • [22] Recent advances in biodynamics of human hand-arm system
    Dong, RG
    Wu, JZ
    Welcome, DE
    INDUSTRIAL HEALTH, 2005, 43 (03) : 449 - 471
  • [23] A study of the modal behavior of the human hand-arm system
    Thomas, C
    Rakheja, S
    Bhat, RB
    Stiharu, I
    JOURNAL OF SOUND AND VIBRATION, 1996, 191 (01) : 171 - 176
  • [24] FURTHER CONTRIBUTIONS TO THE MODELING OF THE HUMAN HAND-ARM SYSTEM
    Gligor, Claudiu Alin
    Arghir, Mariana
    ACTA TECHNICA NAPOCENSIS SERIES-APPLIED MATHEMATICS MECHANICS AND ENGINEERING, 2014, 57 (03): : 429 - 434
  • [25] Effects of vibration on the hand-arm system of miners in India
    Dasgupta, AK
    Harrison, J
    OCCUPATIONAL MEDICINE-OXFORD, 1996, 46 (01): : 71 - 78
  • [26] VIBRATION-TRANSMISSION TO AND EFFECTS ON THE HAND-ARM SYSTEM
    HANSSON, JE
    ERIKSSON, MA
    GEMNE, G
    KIHLBERG, S
    KJELLBERG, A
    JOURNAL OF SOUND AND VIBRATION, 1988, 121 (03) : 582 - 582
  • [27] Measurement of biodynamic response of human hand-arm system
    Dong, R. G.
    Welcome, D. E.
    McDowell, T. W.
    Wu, J. Z.
    JOURNAL OF SOUND AND VIBRATION, 2006, 294 (4-5) : 807 - 827
  • [28] Theoretical Analysis and Optimization of a Gloved Hand-Arm System
    Alabi, Oreoluwa
    Gupta, Sunit K.
    Barry, Oumar
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2021, 143 (09):
  • [29] Vibration energy absorption in the hand-arm system of hand tractor operator
    Dewangan, K. N.
    Tewari, V. K.
    BIOSYSTEMS ENGINEERING, 2009, 103 (04) : 445 - 454
  • [30] ANALYSIS OF THE MECHANICAL MODEL CORRESPONDING TO THE HAND-ARM SYSTEM
    Pop, Aurora Felicia
    Arghir, Mariana
    ANNALS OF DAAAM FOR 2009 & PROCEEDINGS OF THE 20TH INTERNATIONAL DAAAM SYMPOSIUM, 2009, 20 : 1637 - 1638