Establishment and validation of an acid alumina column clean-up for determination of trace citrinin in food samples

被引:0
|
作者
Wang, Xiangyang [1 ]
Ling, Qiaojia [1 ]
Wang, Fang [1 ]
Sheng, Xuerong [1 ]
Shi, Yongqing [3 ]
Gu, Shuang [1 ,2 ]
机构
[1] Zhejiang Gongshang Univ, Sch Food Sci & Biotechnol, Key Lab Fruits & Vegetables Postharvest & Proc Tec, Hangzhou 310018, Peoples R China
[2] Zhejiang Gongshang Univ, Key Lab Food Microbial Technol Zhejiang Prov, Hangzhou 310018, Peoples R China
[3] Zhejiang Gongshang Univ, Sch Food Sci & Biotechnol, Hangzhou 310018, Peoples R China
关键词
Citrinin; Acidic alumina column; Methanol; Impurity removal; Food samples; IMMUNOAFFINITY COLUMN; MONASCUS; RICE;
D O I
10.1007/s11694-023-01971-z
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
Citrinin (CIT) is frequent contamination of red fermented rice as a recognized public health threat. Although various quantitative techniques have been developed for CIT detection, most of these methods require expensive equipment and specially trained personnel. This study was aimed to develop an approach for cleaning up and purifying samples from complex matrix prior to CIT detection by high-performance liquid chromatography-fluorescence (HPLC-FLD). In order to achieve the optimal purification, the effects of 6 kind of traditional carrier adsorption materials and 7 types of eluents with different pH values on CIT recoveries were evaluated. Acidic alumina was finally selected as the optimal packed column for CIT clean-up. Methanol was used to remove the impurities after food extract was loaded on the acidic alumina column, and 80% methanol solution (pH 2.1) was used for CIT elution. Standard recovery test showed that the average recoveries for CIT-spiked samples after second elution was 91.46%, which was significantly higher than that of commercial immunoaffinity column. To examine the applicability of the proposed method, 29 kinds of food samples were treated with methanol and 80% methanol (pH 2.1) before HPLC analysis. Result showed that all samples tested positive for CIT, soy sauce and red fermented bean curd contained the highest levels of CIT contamination, indicating the feasibility of acidic alumina column with specific elution method. The proposed method would provide a new alternative approach for CIT enrichment, through a simple, reusable, cheap, and environmentally friendly solid-phase extraction procedure.
引用
收藏
页码:4371 / 4383
页数:13
相关论文
共 50 条
  • [41] Liquid chromatographic determination of fumonisins B1 and B2 in corn samples after reusable immunoaffinity column clean-up
    Abramovic, BF
    Jaksic, SM
    Masic, ZS
    JOURNAL OF THE SERBIAN CHEMICAL SOCIETY, 2005, 70 (06) : 899 - 910
  • [42] Development of a New Clean-up Method for the Determination of 5-methyl-tetrahydrofolate in Milk Samples Using a Sol-Gel β-Lactoglobulin Column
    T. Hrebicek
    M. Cichna-Markl
    Journal of Sol-Gel Science and Technology, 2005, 36 : 275 - 283
  • [43] Supercritical fluid extraction as an on-line clean-up technique for determination of riboflavin vitamins in food samples by capillary electrophoresis with fluorimetric detection
    Zougagh, Mohammed
    Rios, Angel
    ELECTROPHORESIS, 2008, 29 (15) : 3213 - 3219
  • [44] A scFv Antibody-Based Immunoaffinity Chromatography Column for Clean-Up of Bisphenol A-Contaminated Water Samples
    Inui, Hideyuki
    Takehara, Akira
    Doi, Fumito
    Nishi, Kosuke
    Takai, Mikio
    Miyake, Shiro
    Ohkawa, Hideo
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (02) : 353 - 358
  • [45] Determination of ochratoxin A in wine by means of immunoaffinity column clean-up and high-performance liquid chromatography
    Visconti, A
    Pascale, M
    Centonze, G
    JOURNAL OF CHROMATOGRAPHY A, 1999, 864 (01) : 89 - 101
  • [46] In-house validation of an improved sample extraction and clean-up method for GC determination of isomers of nervonic acid in meat products
    Agazzi, ME
    Bau, A
    Barcarolo, R
    Luecker, E
    Barrero-Moreno, J
    Anklam, E
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 376 (03) : 360 - 365
  • [47] In-house validation of an improved sample extraction and clean-up method for GC determination of isomers of nervonic acid in meat products
    Marie-Elisabeth Agazzi
    Andrea Bau
    Robertino Barcarolo
    Ernst Luecker
    Josefa Barrero-Moreno
    Elke Anklam
    Analytical and Bioanalytical Chemistry, 2003, 376 : 360 - 365
  • [48] Graphene Adsorbent-Based Solid-Phase Extraction for Aflatoxins Clean-Up in Food Samples
    Feizy, Javad
    Jahani, Moslem
    Beigbabaei, Adel
    CHROMATOGRAPHIA, 2019, 82 (06) : 917 - 926
  • [49] Determination of Sudan I by high performance liquid chromatography with immuno-affinity column clean-up
    Zhu, Lixin
    Meng, Wei
    Qiu, Xuemei
    Liu, Renrong
    Xu, Ling
    Xu, Fuyong
    ADVANCES IN CHEMICAL ENGINEERING III, PTS 1-4, 2013, 781-784 : 1694 - 1699
  • [50] Graphene Adsorbent-Based Solid-Phase Extraction for Aflatoxins Clean-Up in Food Samples
    Javad Feizy
    Moslem Jahani
    Adel Beigbabaei
    Chromatographia, 2019, 82 : 917 - 926