Feasibility Of Noninvasive Assessment of Cardiac Output During Exercise In Healthy Adults By A Novel Elaboration On Systolic TimeIntervals

被引:0
|
作者
Kim, Chul-Ho [1 ]
Cierzan, Bradley S. [1 ]
Patel, Nisha [1 ]
Borlaug, Barry A. [1 ]
Johnson, Bruce D. [1 ,2 ]
机构
[1] Mayo Clin, Dept Cardiovasc Dis, Rochester, MN 55905 USA
[2] Mayo Clin, Dept Cardiovasc Dis, Med & Physiol, 200 First St SW, Rochester, MN 55905 USA
关键词
Systolic time interval; cardiac output; exercise; hemodynamic; TIME INTERVALS;
D O I
10.1159/000533574
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND. Although assessment of cardiovascular hemodynamics during exercise can provide clinical insights, it is challenging to acquire it in clinical settings.OBJECTIVES. Accordingly, this preliminary study was to determine whether a novel elaboration on Systolic Time Interval measures (eSTICO) method of quantifying Cardiac Output and Stroke Volume was comparable to those obtained using a validated soluble gas (OpCircCO) method or calculation based on oxygen consumption (VO2CO) during exercise. METHODS. For the present study, 14 healthy subjects (male: n=12, female: n= 2) performed incremental exercise on a recumbent cycle ergometer. At rest and during exercise, cardiac output (CO) was obtained via the eSTICO method while the OpenCircCO and VO2CO measures were obtained at the last minute of each workload.RESULTS. At peak, there was no difference between eSTICO and OpCircCO (12.39 +/- 3.06 vs. 13.96 +/- 2.47 L/min, p>0.05) while there was a slight difference between eSTICO and VO2CO (12.39 +/- 3.06 vs. 14.28 +/- 2.55 L/min, p<0.05). When we performed correlation analysis with all subjects and all measures of CO at all WL, between eSTICO and OpenCircCO, there was a good relationship (r=0.707, p<0.001) with a Bland and Altman agreement analysis demonstrating a -1.6 difference (95% LoA: -6.3-3.5). Between eSTICO and VO2CO, we observed an r=0.865 (p<0.001) and a Bland and Altman agreement analysis with a-1.2 difference (95% LoA:-4.8-2.4).CONCLUSION. A novel exploitation of cardiac hemodynamics using systolic timing intervals may allow a relatively good assessment of cardiac output during exercise in healthy adults.
引用
收藏
页码:183 / 187
页数:5
相关论文
共 50 条
  • [21] Evaluation of a Novel Cardiac Output Index on Healthy Elderly, Cardiovascular and Heart Failure Patients during Dynamic Exercise
    Wang, L.
    Poon, C. C. Y.
    Yip, Gabriel
    Yu, Cheuk Man
    Zhang, Y. T.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 1515 - 1518
  • [22] NONINVASIVE ASSESSMENT OF CARDIAC-OUTPUT AND STROKE VOLUME IN PATIENTS DURING EXERCISE - EVALUATION OF A CO2-REBREATHING METHOD
    OHLSSON, J
    WRANNE, B
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1986, 55 (05): : 538 - 544
  • [23] AN AUTOMATED, INDIRECT ASSESSMENT OF CARDIAC-OUTPUT DURING REST AND EXERCISE
    WILMORE, JH
    FARRELL, PA
    NORTON, AC
    COTE, RW
    COYLE, EF
    EWY, GA
    TEMKIN, LP
    BILLING, JE
    JOURNAL OF APPLIED PHYSIOLOGY, 1982, 52 (06) : 1493 - 1497
  • [24] Multidimensional breathlessness assessment during cardiopulmonary exercise testing in healthy adults
    Hayley Lewthwaite
    Dennis Jensen
    European Journal of Applied Physiology, 2021, 121 : 499 - 511
  • [25] Multidimensional breathlessness assessment during cardiopulmonary exercise testing in healthy adults
    Lewthwaite, Hayley
    Jensen, Dennis
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2021, 121 (02) : 499 - 511
  • [26] Reduced Cardiac Load During Aerobic Eccentric Exercise in Healthy Older Adults
    Clements, Richard E.
    Gault, Mandy L.
    Willems, Mark E. T.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2011, 43 (05): : 933 - 933
  • [27] The comfort assessment in healthy adults during constant-flow mode in noninvasive ventilator
    Yao, Juanjuan
    Li, Wei
    Peng, Mengmeng
    He, Kaixin
    Ma, Dedong
    Lu, Hongxiu
    CLINICAL RESPIRATORY JOURNAL, 2022, 16 (02): : 123 - 129
  • [28] Noninvasive continuous cardiac output and cerebral perfusion monitoring in term infants with neonatal encephalopathy: assessment of feasibility and reliability
    Eva Forman
    Colm R Breatnach
    Stephanie Ryan
    Jana Semberova
    Jan Miletin
    Adrienne Foran
    Afif EL-Khuffash
    Pediatric Research, 2017, 82 : 789 - 795
  • [29] Noninvasive continuous cardiac output and cerebral perfusion monitoring in term infants with neonatal encephalopathy: assessment of feasibility and reliability
    Forman, Eva
    Breatnach, Colm R.
    Ryan, Stephanie
    Semberova, Jana
    Miletin, Jan
    Foran, Adrienne
    EL-Khuffash, Afif
    PEDIATRIC RESEARCH, 2017, 82 (05) : 789 - 795
  • [30] NONINVASIVE MEASUREMENT OF CARDIAC-OUTPUT BY A CARBON-DIOXIDE REBREATHING METHOD AT REST AND DURING EXERCISE
    NUGENT, AM
    MCPARLAND, J
    MCENEANEY, DJ
    STEELE, I
    CAMPBELL, NPS
    STANFORD, CF
    NICHOLLS, DP
    EUROPEAN HEART JOURNAL, 1994, 15 (03) : 361 - 368