Effect of X-Ray Computed Tomography Imaging Parameters on Quantification of Petrophysical Properties

被引:5
|
作者
Salek, M. F. [1 ]
Beckingham, L. E. [1 ]
机构
[1] Auburn Univ, Dept Civil & Environm Engn, Auburn, AL 36830 USA
基金
美国国家科学基金会;
关键词
imaging; X-ray computed tomography; surface area; pore size distribution; pore connectivity; porosity; PORE STRUCTURE CHARACTERIZATION; REACTIVE SURFACE-AREA; POROUS-MEDIA; CARBON-DIOXIDE; SCALE ANALYSIS; OIL-RECOVERY; SANDSTONE; STORAGE; RATES; FLOW;
D O I
10.1029/2023EA003095
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
Three-dimensional (3D) X-ray computed tomography (X-ray CT) imaging has emerged as a nondestructive means of microstructural characterization. However, obtaining and processing high-quality and high-resolution images is time-consuming and often requires high-performance computing, particularly with a high number of projections. This work evaluates the effect of 3D X-ray CT imaging parameters on pore connectivity and surface area quantification in sandstone samples of varied composition. Samples from Bentheimer and Torrey Buff formations are imaged via 3D X-ray CT imaging at resolutions ranging from 1.25 to 15 mu m, bin sizes 1, 2, and 4, and number of projections from 400 to 4,500. Collected images are processed and analyzed using ImageJ and MATLAB to discern petrophysical properties and the results are compared with each other and Mercury Intrusion Capillary Pressure (MICP) results. Overall, little variation in bulk porosity with changing scanning parameters is observed. However, for low resolution and projection numbers, connected porosity is lower compared to bulk porosity due to a failure to capture microfeatures. Overall, mineral surface area is observed to decrease with increasing bin size, voxel size, and projection numbers, except an observed increase with projection numbers for Torrey Buff. The Torrey Buff samples contains comparatively more clays and even the highest resolution (1.25 mu m) fails to separate the micrograins, which is reflected in the pore size distribution. Identifying these variations are helpful as discrepancies in imaged pore connectivity and surface area can largely impact assessments of fluid flow and transport in reactive transport simulations informed by this data. Three-dimensional X-ray computed tomography images of two sandstones studied with different scanning parameters Mineral accessible surface area and pore connectivity are affected by voxel size, bin size, and number of image projections Variations in petrophysical properties more pronounced for high clay sample
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Correlative single-cell hard X-ray computed tomography and X-ray fluorescence imaging
    Zihan Lin
    Xiao Zhang
    Purbasha Nandi
    Yuewei Lin
    Liguo Wang
    Yong S. Chu
    Timothy Paape
    Yang Yang
    Xianghui Xiao
    Qun Liu
    Communications Biology, 7
  • [32] Correlative single-cell hard X-ray computed tomography and X-ray fluorescence imaging
    Lin, Zihan
    Zhang, Xiao
    Nandi, Purbasha
    Lin, Yuewei
    Wang, Liguo
    Chu, Yong S.
    Paape, Timothy
    Yang, Yang
    Xiao, Xianghui
    Liu, Qun
    COMMUNICATIONS BIOLOGY, 2024, 7 (01)
  • [33] X-ray Fluorescence Computed Tomography (XFCT) Imaging with a Superfine Pencil Beam X-ray Source
    Romero, Ignacio O.
    Fang, Yile
    Lun, Michael
    Li, Changqing
    PHOTONICS, 2021, 8 (07)
  • [34] Industrial X-ray computed tomography
    Pechstein, Torsten
    TM-TECHNISCHES MESSEN, 2020, 87 (02) : 79 - 80
  • [35] Dynamic X-ray computed tomography
    Bonnet, S
    Koenig, A
    Roux, S
    Hugonnard, P
    Guillemaud, R
    Grangeat, P
    PROCEEDINGS OF THE IEEE, 2003, 91 (10) : 1574 - 1587
  • [36] Design for X-Ray Computed Tomography
    Moroni, Giovanni
    Petro, Stefano
    29TH CIRP DESIGN CONFERENCE 2019, 2019, 84 : 173 - 178
  • [37] Industrial computed X-ray tomography
    Luthi, T
    Flisch, A
    Wyss, P
    INSIGHT, 1998, 40 (03) : 196 - 197
  • [38] Dose in x-ray computed tomography
    Kalender, Willi A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : R129 - R150
  • [39] X-ray computed tomography of the heart
    Wijesekera, Nevin T.
    Duncan, Mark K.
    Padley, Simon P. G.
    BRITISH MEDICAL BULLETIN, 2010, 93 (01) : 49 - 67
  • [40] Fiber orientation quantification utilizing X-ray micro-computed tomography
    Sietins, Jennifer M.
    Sun, Jessica C.
    Knorr, Daniel B., Jr.
    JOURNAL OF COMPOSITE MATERIALS, 2021, 55 (08) : 1109 - 1118