The Diagnostic Accuracy of Sonography for Detecting Placenta Accreta Spectrum in Pregnant Women, With Placenta Previa

被引:0
|
作者
Golshan, Rosa [1 ]
Faraji, Ali [1 ]
Mohtasham, Masoumeh Ahmadi [1 ]
Eghbali, Elham [1 ]
Ghatrehsamani, Fatemeh [1 ]
Khalafi, Mohammad [1 ]
Karbasi, Mahsa [1 ,2 ]
机构
[1] Tabriz Univ Med Sci, Imam Reza Hosp, Dept Gen Radiol, Tabriz, Iran
[2] Tabriz Univ Med Sci, Imam Reza Hosp, Dept Gen Radiol, Golgasht St, Tabriz 51368, Iran
关键词
prenatal diagnosis; placenta accreta spectrum; placenta accreta; placenta increta; placenta percreta; placenta previa; and sonography; ANTENATAL DIAGNOSIS; INVASIVE PLACENTATION; PRENATAL-DIAGNOSIS; ADHERENT PLACENTA; ULTRASOUND; PREDICTION; MORBIDITY; DOPPLER; MRI;
D O I
10.1177/87564793231176024
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective:A placenta accreta spectrum (PAS) refers to a condition in which there is an abnormal penetration of the placenta, within the walls of the uterus. This study was designed to assess the overall diagnostic accuracy of sonography in detecting myometrium invasion of the placenta, in pregnant women with placenta previa (PP).Materials and Methods:In this study, 70 participants were placed into groups with either an anterior placenta (APL) or a posterior placenta (PPL). An experienced radiologist examined the participants. At least two well-known diagnostic sonographic signs were considered, as the diagnostic criteria of PAS.Results:Sonography diagnosed 30 cases of PAS out of 43 confirmed cases, with a sensitivity of 70%, specificity of 77%, positive predictive value (PPV) of 83% and negative predictive value (NPV) of 61%, accuracy of 72.8%, precision of 69.1%, diagnostic odd ratio (DOR) of 21.06, and an F measure of 0.71. Detection rates were higher in cases of the APL (sensitivity: 78%, specificity: 91%, PPV: 94%, NPV: 68%, accuracy: 82.8%, precision: 78.2%, DOR: 39.12, and an F measure: 0.78). The review of sonograms allowed for the detection of seven cases (10%) of PAS appropriately.Conclusion:The sonographic results seem to be more accurate among individuals with APL than PPL. A replication of this study, with multicenter participation is recommended, especially in cases of PPL.
引用
收藏
页码:471 / 479
页数:9
相关论文
共 50 条
  • [31] Clinical and Ultrasound Predictors of Placenta Accreta in Pregnant Women with Antepartum Diagnosis of Placenta Previa: A Multicenter Study
    De Vita, Davide
    Capobianco, Giampiero
    Gerosolima, Giovanni
    Sciorio, Carmen
    Coppola, Ermenegilda
    Parazzini, Fabio
    Silvestri, Maurizio
    Caruso, Anna Paola
    Morlando, Maddalena
    Petta, Raffaele
    Pascarella, Alessandro
    Dessole, Salvatore
    Viora, Elsa
    GYNECOLOGIC AND OBSTETRIC INVESTIGATION, 2019, 84 (03) : 242 - 247
  • [32] Abnormal Placentation Placenta Previa, Vasa Previa, and Placenta Accreta
    Silver, Robert M.
    OBSTETRICS AND GYNECOLOGY, 2015, 126 (03): : 654 - 668
  • [33] PLACENTA ACCRETA - WITH SPECIAL REFERENCE TO COMBINED PLACENTA PREVIA AND ACCRETA
    DIMASI, FT
    MCGOLDRICK, DM
    GROGAN, RH
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1963, 87 (02) : 190 - &
  • [34] SIMULTANEOUSLY OCCURRING PLACENTA PREVIA AND PLACENTA ACCRETA
    KISTNER, RW
    HERTIG, AT
    REID, DE
    SURGERY GYNECOLOGY & OBSTETRICS, 1952, 94 (02): : 141 - 151
  • [35] PLACENTA ACCRETA, PERCRETA AND PREVIA ACCRETA
    KITCHEN, DH
    AUSTRALIAN & NEW ZEALAND JOURNAL OF OBSTETRICS & GYNAECOLOGY, 1978, 18 (04): : 238 - 241
  • [36] Prediction of Placenta Accreta Spectrum by Prenatal Ultrasound Staging System in Women with Placenta Previa with Scarred Uterus
    Upma Saxena
    Monika Rana
    Shiwani Tripathi
    Ritu Nair Misra
    Poonam Khambra
    The Journal of Obstetrics and Gynecology of India, 2023, 73 : 191 - 198
  • [37] Prediction of Placenta Accreta Spectrum by Prenatal Ultrasound Staging System in Women with Placenta Previa with Scarred Uterus
    Saxena, Upma
    Rana, Monika
    Tripathi, Shiwani
    Misra, Ritu Nair
    Khambra, Poonam
    JOURNAL OF OBSTETRICS AND GYNECOLOGY OF INDIA, 2023, 73 (SUPPL 2): : 191 - 198
  • [38] Diagnostic Accuracy of Placental Thickness in Lower Uterine Segment Measured by Ultrasound in Prediction of Placenta Accreta Spectrum in Patients with Placenta Previa. A Diagnostic Test Accuracy Study
    Elmaraghy, Ahmed Mohammed
    Fayed, Salah Taha
    Ali, Mahmoud Abd ElHamid
    Hassanien, Monira Ali
    Mamdouh, Ahmed Mohamed
    INTERNATIONAL JOURNAL OF WOMENS HEALTH, 2023, 15 : 311 - 320
  • [39] Association of the placenta accreta spectrum score and estimated blood loss in placenta accreta spectrum patients with placenta previa: a retrospective cohort study
    Fusen Huang
    Jingjie Wang
    Qiuju Xiong
    Wenjian Wang
    Yi Xu
    Jia Zhuo
    Qiuling Xia
    Xiaonan Liu
    Journal of Anesthesia, 2022, 36 : 715 - 722
  • [40] Association of the placenta accreta spectrum score and estimated blood loss in placenta accreta spectrum patients with placenta previa: a retrospective cohort study
    Huang, Fusen
    Wang, Jingjie
    Xiong, Qiuju
    Wang, Wenjian
    Xu, Yi
    Zhuo, Jia
    Xia, Qiuling
    Liu, Xiaonan
    JOURNAL OF ANESTHESIA, 2022, 36 (06) : 715 - 722