Cadaveric biomechanical assessment of different configurations for a novel pin and plate fixation method in distal humerus fractures

被引:0
|
作者
Same, Kaveh [1 ]
Hakiminejad, Alireza [2 ]
Nourani, Amir [2 ]
Nabian, Mohammad Hossein [1 ]
Foruozesh, Mehdi [3 ]
Kamrani, Reza Shahriar [1 ]
机构
[1] Univ Tehran Med Sci, Shariati Hosp, Ctr Orthoped Transdisciplinary Appl Res, Jalal Al Ahmad Highway, Tehran, Iran
[2] Sharif Univ Technol, Dept Mech Engn, Azadi St, Tehran, Iran
[3] Legal Med Org, Legal Med Res Ctr, Tehran, Iran
关键词
BONE-MINERAL DENSITY; SYSTEMS; OSTEOSYNTHESIS; PARALLEL; STABILIZATION; EPIDEMIOLOGY; STABILITY;
D O I
10.1038/s41598-023-50976-7
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Use of dual pre-contoured plates has been accepted as the treatment of choice in distal humerus fractures despite challenges especially in very distal or highly fragmented fractures. Aiming to improve results in such instances, our newly proposed method uses several K-wires fixated by a small reconstruction plate. Drawing on the results of previous finite element studies, the current study aims to compare the stiffness of three clinically common variations of this method using biomechanical testing in cadaveric humeri. 24 samples were divided into three groups and fractures were simulated. Groups I and II used 1.5 mm K-wires in differing configurations while 2 mm wires were used in group III. All samples underwent compression, anterior and posterior bending, and torsional testing as well as failure testing. Our results indicated that Group III had significantly higher stiffness in flexion, extension, and torsion (p < 0.05). In failure, group III had the highest mean stiffness in anterior bending and torsion (861.2 N, 30.9 Nm). Based on previous and current results, this new Persian fixation method, especially when implemented using 2 mm K-wires, shows promise in achieving suitable stability and may be useful as an alternative approach in complex distal humerus fractures.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] A BIOMECHANICAL ANALYSIS OF PROPHYLACTIC FIXATION FOR PATHOLOGICAL FRACTURES OF THE DISTAL 3RD OF THE HUMERUS
    DAMRON, TA
    HEINER, JP
    FREUND, EMN
    DAMRON, LA
    MCCABE, R
    VANDERBY, R
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (06): : 839 - 847
  • [32] Percutaneous fixation of intraarticular joint-depression calcaneal fractures with different screw configurations - a biomechanical human cadaveric analysis
    Ivanov, Stoyan
    Stefanov, Aleksandar
    Zderic, Ivan
    Rodemund, Christian
    Schepers, Tim
    Gehweiler, Dominic
    Dauwe, Jan
    Pastor, Torsten
    Makelov, Biser
    Raykov, Dimitur
    Richards, Geoff
    Gueorguiev, Boyko
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2022, 48 (04) : 3305 - 3315
  • [33] Percutaneous fixation of intraarticular joint-depression calcaneal fractures with different screw configurations – a biomechanical human cadaveric analysis
    Stoyan Ivanov
    Aleksandar Stefanov
    Ivan Zderic
    Christian Rodemund
    Tim Schepers
    Dominic Gehweiler
    Jan Dauwe
    Torsten Pastor
    Biser Makelov
    Dimitur Raykov
    Geoff Richards
    Boyko Gueorguiev
    European Journal of Trauma and Emergency Surgery, 2022, 48 : 3305 - 3315
  • [34] Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
    Jabran, Ali
    Peach, Chris
    Zou, Zhenmin
    Ren, Lei
    BIOMEDICAL ENGINEERING ONLINE, 2018, 17
  • [35] Hybrid blade and locking plate fixation for proximal humerus fractures: a comparative biomechanical analysis
    Ali Jabran
    Chris Peach
    Zhenmin Zou
    Lei Ren
    BioMedical Engineering OnLine, 17
  • [36] Semitubular blade plate fixation in proximal humeral fractures: A biomechanical study in a cadaveric model
    Instrum, K
    Fennell, C
    Shrive, N
    Damson, E
    Sonnabend, D
    Hollinshead, R
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 1998, 7 (05) : 462 - 466
  • [37] Biomechanical Evaluation of Different Plate Configurations for Midshaft Clavicle Fracture Fixation
    Kitzen, Joep
    Paulson, Kent
    Korley, Robert
    Duffy, Paul
    Martin, C. Ryan
    Schneider, Prism S.
    JBJS OPEN ACCESS, 2022, 7 (01)
  • [38] Biomechanical evaluation of intramedullary nail and bone plate for the fixation of distal metaphyseal fractures
    Nourisa, Jalil
    Rouhi, Gholamreza
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2016, 56 : 34 - 44
  • [39] Biomechanical Properties of Volar Hybrid and Locked Plate Fixation in Distal Radius Fractures
    Sokol, Shima C.
    Amanatullah, Derek F.
    Curtiss, Shane
    Szabo, Robert M.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2011, 36A (04): : 591 - 597
  • [40] Precontoured Parallel Plate Fixation of AO/OTA Type C Distal Humerus Fractures
    Athwal, George S.
    Hoxie, Samuel C.
    Rispoli, Damian M.
    Steinmann, Scott P.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2009, 23 (08) : 575 - 580