Feasibility and accuracy of real-time 3D-holographic graft length measurements

被引:1
|
作者
Tsai, Tsung-Ying [1 ,2 ]
Kageyama, Shigetaka [2 ]
He, Xingqiang [2 ]
Pompilio, Giulio [3 ,4 ]
Andreini, Daniele [4 ,5 ,6 ]
Pontone, Gianluca [4 ,7 ]
La Meir, Mark [8 ]
De Mey, Johan [9 ]
Tanaka, Kaoru [10 ]
Doenst, Torsten [11 ]
Puskas, John [12 ]
Teichgraeber, Ulf
Schneider, Ulrich [11 ,13 ]
Gupta, Himanshu [14 ]
Leipsic, Jonathon [15 ]
Garg, Scot [16 ]
C. Revaiah, Pruthvi [2 ]
Stanuch, Maciej [17 ,18 ]
Skalski, Andrzej [17 ,18 ]
Onuma, Yoshinobu [2 ]
Serruys, Patrick W. [2 ]
机构
[1] Taichung Vet Gen Hosp, Cardiovasc Ctr, Taichung, Taiwan
[2] Univ Galway, Corrib Res Ctr Adv Imaging & Core Lab, Univ Rd, Galway H91TK33, Ireland
[3] Ctr Cardiol Monzino IRCCS, Dept Cardiovasc Surg, Milan, Italy
[4] Univ Milan, Dept Biomed Surg & Dent Sci, Milan, Italy
[5] IRCCS Galeazzi St Ambrogio, Div Cardiol & Cardiac Imaging, Milan, Italy
[6] Univ Milan, Dept Biomed & Clin Sci, Milan, Italy
[7] Ctr Cardiol Monzino IRCCS, Dept Perioperat Cardiol & Cardiovasc Imaging, Milan, Italy
[8] Univ Ziekenhuis Brussel, Dept Cardiac Surg, VUB, Brussels, Belgium
[9] Univ Ziekenhuis Brussel UZ Brussel, Dept Radiol, Brussels, Belgium
[10] Univ Hosp Brussels, Dept Radiol, Brussels, Belgium
[11] Univ Hosp Jena, Dept Cardiothorac Surg, Jena, Germany
[12] Mt Sinai Morningside Hosp, Dept Cardiovasc Med, New York, NY USA
[13] Univ Hosp Jena, Dept Radiol, Jena, Germany
[14] Valley Hosp, Dept Cardiol & Radiol, Ridgewood, NJ USA
[15] Univ British Columbia, St Pauls Hosp, Ctr Cardiovasc Innovat, Vancouver, BC, Canada
[16] Royal Blackburn Hosp, Dept Cardiol, Blackburn, England
[17] MedApp SA, Krakow, Poland
[18] AGH Univ Sci & Technol, Dept Measurements & Elect, Krakow, Poland
来源
关键词
Augmented reality; Mixed reality; Coronary artery bypass graft; Computed tomography; Hologram;
D O I
10.1093/ehjdh/ztad071
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Mixed reality (MR) holograms can display high-definition images while preserving the user's situational awareness. New MR software can measure 3D objects with gestures and voice commands; however, these measurements have not been validated. We aimed to assess the feasibility and accuracy of using 3D holograms for measuring the length of coronary artery bypass grafts. Methods and results An independent core lab analyzed follow-up computer tomography coronary angiograms performed 30 days after coronary artery bypass grafting in 30 consecutive cases enrolled in the FASTTRACK CABG trial. Two analysts, blinded to clinical information, performed holographic reconstruction and measurements using the CarnaLife Holo software (Medapp, Krakow, Poland). Inter-observer agreement was assessed in the first 20 cases. Another analyst performed the validation measurements using the CardIQ W8 CT system (GE Healthcare, Milwaukee, Wisconsin). Seventy grafts (30 left internal mammary artery grafts, 31 saphenous vein grafts, and 9 right internal mammary artery grafts) were measured. Holographic measurements were feasible in 97.1% of grafts and took 3 minutes 36 s +/- 50.74 s per case. There was an excellent inter-observer agreement [interclass correlation coefficient (ICC) 0.99 (0.97-0.99)]. There was no significant difference between the total graft length on hologram and CT [187.5 mm (157.7-211.4) vs. 183.1 mm (156.8-206.1), P = 0.50], respectively. Hologram and CT measurements are highly correlated (r = 0.97, P < 0.001) with an excellent agreement [ICC 0.98 (0.97-0.99)]. Conclusion Real-time holographic measurements are feasible, quick, and accurate even for tortuous bypass grafts. This new methodology can empower clinicians to visualize and measure 3D images by themselves and may provide insights for procedural strategy.
引用
收藏
页码:101 / 104
页数:4
相关论文
共 50 条
  • [21] Real-time pupil tracking backlight system for holographic 3D display
    Choo, Hyon-Gon
    Park, Minsik
    Kim, Hyun-Eui
    Bae, Chanyeol
    Chae, Byung Gyu
    Kim, Hwi
    Moon, Kyungae
    Kim, Jinwoong
    Hahn, Joonku
    CHINESE OPTICS LETTERS, 2014, 12 (06)
  • [22] Feasibility and Potential for Real-Time 3D Vitreoretinal Surgery Telementoring
    Seddon, Ian A.
    Rahimy, Ehsan
    Miller, John B.
    Charles, Steve
    Kitchens, John
    Houston, Samuel Kenney
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2023, 43 (12): : 2162 - 2165
  • [23] REAL-TIME MEASUREMENTS OF BIOMARKERS FOR GRAFT ASSESSMENT AND PATIENT MONITORING
    Huwyler, Florian
    Eden, Janina
    Binz, Jonas
    Cunningham, Leslie
    Da Silva, Richard Sousa
    Hefti, Max
    Clavien, Pierre A.
    Dutkowski, Philipp
    Tibbitt, Mark William
    HEPATOLOGY, 2023, 78 : S236 - S236
  • [24] Feasibility study: Real-time 3-D ultrasound imaging of the brain
    Smith, SW
    Chu, K
    Idriss, SF
    Ivancevich, NM
    Light, ED
    Wolf, PD
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2004, 30 (10): : 1365 - 1371
  • [25] MEASUREMENTS OF LEG LENGTH AND LEG LENGTH INEQUALITY USING REAL-TIME SONOGRAPHY
    HOLST, A
    THOMAS, W
    LUTTEN, C
    ZEITSCHRIFT FUR RHEUMATOLOGIE, 1987, 46 (05): : 284 - 284
  • [26] ACCURACY OF REAL-TIME SONOGRAPHIC MEASUREMENTS IN LIVER SIZE CONTROLS
    MERGELSBERG, M
    WEBER, M
    MUSCH, E
    ULTRASCHALL IN DER MEDIZIN, 1988, 9 (06): : 293 - 298
  • [27] Accuracy improvement of real-time load-pull measurements
    Teppati, Valeria
    Ferrero, Andrea
    Parena, Daniela
    Pisani, Umberto
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2007, 56 (02) : 610 - 613
  • [28] Feasibility and accuracy of real-time 3-dimensional echocardiographic assessment of ventricular septal defects
    van den Bosch, Atincinicrt E.
    Ten Harkel, Derk-Jan
    McGhie, Jackie S.
    Roos-Hesselink, Jolien W.
    Simoons, Maarten L.
    Bogers, Ad J. J. C.
    Meijboom, Folkert J.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2006, 19 (01) : 7 - 13
  • [29] About Testing of Factors Affecting the Accuracy of pediatric Distance and Volume Measurements in the Real-time 3D Echocardiography
    Putzke, M.
    Hoeller, T.
    Breuer, J.
    Herberg, U.
    CLINICAL RESEARCH IN CARDIOLOGY, 2011, 100 (09) : 840 - 841
  • [30] Real time 3D Holographic display
    Loreti, Luigi
    Ceccarelli, R.
    Loreti, A.
    Borro, A.
    EMERGING DIGITAL MICROMIRROR DEVICE BASED SYSTEMS AND APPLICATIONS IV, 2012, 8254