Impact on the image quality of modified reduced field-of-view diffusion-weighted magnetic resonance imaging of pancreatic adenocarcinoma using spatially tailored two-dimensional radiofrequency pulses with a tilted excitation plane: A comparison with conventional field-of-view imaging
被引:2
|作者:
Tanabe, Masahiro
[1
]
Hideura, Keiko
[1
]
Higashi, Mayumi
[1
]
Ihara, Kenichiro
[1
]
Inoue, Atsuo
[1
]
Narikiyo, Koji
[1
]
Benkert, Thomas
[2
]
Imai, Hiroshi
[3
]
Yamane, Masatoshi
[4
]
Yamaguchi, Takahiro
[4
]
Shimokawa, Mototsugu
[5
]
Ito, Katsuyoshi
[1
]
机构:
[1] Yamaguchi Univ, Grad Sch Med, Dept Radiol, 1-1-1 Minami Kogushi, Ube, Yamaguchi 7558505, Japan
[2] Siemens Healthcare GmbH, MR Applicat Predev, Erlangen, Germany
[3] Siemens Healthcare KK, MR Res & Collaborat, Tokyo, Japan
[4] Yamaguchi Univ, Dept Radiol Technol, Ube, Japan
[5] Yamaguchi Univ, Dept Biostat, Grad Sch Med, Ube, Japan
关键词:
Pancreatic ductal carcinoma;
Diffusion MRI;
Signal-to-noise ratio;
Artifacts;
MRI;
DWI;
D O I:
10.1016/j.ejrad.2023.111138
中图分类号:
R8 [特种医学];
R445 [影像诊断学];
学科分类号:
1002 ;
100207 ;
1009 ;
摘要:
Purpose: Modified reduced FOV diffusion-weighted imaging (DWI) using spatially-tailored 2D RF pulses with tilted excitation plane (tilted r-DWI) has been developed. The purpose of this study was to evaluate the impact on image quality and quantitative apparent diffusion coefficient (ADC) values of tilted r-DWI for pancreatic ductal adenocarcinomas (PDAC) in comparison to conventional full-FOV DWI (f-DWI).Methods: This retrospective study included 21 patients (mean 70.7, range 50-85 years old) with pathologically confirmed PDAC. All MR images were obtained using 3 T systems. Two radiologists evaluated presence of blurring or ghost artifacts, susceptibility artifacts, and aliasing artifacts; anatomic visualization of the pancreas; interslice signal homogeneity; overall image quality; and conspicuity of the PDAC. For quantitative analysis, contrast-to-noise ratio (CNR), signal-to-noise ratio (SNR), signal-intensity ratio (SIR) and ADC values were measured using regions of interest.All image quality scores except aliasing artifacts in tilted r-DWI were significantly higher than those in f-DWI (p < 0.01). The CNR and SIR of PDAC were significantly higher in tilted r-DWI than in f-DWI (6.7 +/- 4.4 vs. 4.7 +/- 3.9, 2.02 +/- 0.72 vs. 1.72 +/- 0.60, p < 0.01). Conversely, the SNR of PDAC in tilted r-DWI was significantly lower than that in f-DWI (56.0 +/- 33.1 vs. 113.6 +/- 67.3, p < 0.01). No significant difference was observed between mean ADC values of the PDAC calculated from tilted r-DWI (tilted r-ADC) and those from f-DWI (f-ADC) (1225 +/- 250 vs. 1294 +/- 302, p = 0.11).Conclusion: The r-DWI using 2D RF techniques with a tilted excitation plane was shown to significantly improve the image quality and CNR and reduce image artifacts compared to f-DWI techniques in MRI evaluations of PDAC without significantly affecting ADC values.