Development and experimental validation of a dynamic numerical model for human articular cartilage

被引:1
|
作者
Mellors, Ben [1 ]
Allen, Piers [1 ,5 ]
Lavecchia, Carolina E. [2 ]
Mountcastle, Sophie [1 ]
Cooke, Megan E. [3 ]
Lawless, Bernard M. [2 ]
Cox, Sophie C. [4 ]
Jones, Simon [3 ]
Espino, Daniel M. [2 ]
机构
[1] Univ Birmingham, Dept Chem, Phys Sci Hlth CDT, Birmingham, England
[2] Univ Birmingham, Dept Mech Engn, Birmingham, England
[3] Univ Birmingham, Inst Inflammat & Ageing, Birmingham, England
[4] Univ Birmingham, Sch Chem Engn, Birmingham, England
[5] Univ Birmingham, Dept Mech Engn, Birmingham B15 2TT, England
基金
英国工程与自然科学研究理事会;
关键词
Articular cartilage; dynamic mechanical analysis; finite element analysis; hyperelastic; transient; VISCOELASTIC PROPERTIES; COMPRESSIVE MODULUS; STRESS; INDENTATION; FRICTION; STRAINS;
D O I
10.1177/09544119231180901
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to create a preliminary set of experimentally validated Finite Element Analysis (FEA) models, in order to predict the dynamic mechanical behaviour of human articular cartilage (AC). Current models consider static loading with limited independent experimental validation, while the models for this study assess dynamic loading of AC, with direct comparison and validation to physical testing. Three different FEA models of AC were constructed, which considered both linear elastic and hyperelastic models; Neo-Hookean and Ogden. Models were validated using the data collected from compression testing of human femoral heads across 0-1.7 MPa (quasi-static tests and dynamic mechanical analysis). The linear elastic model was inadequate, with a 10-fold over prediction of the displacement dynamic amplitude. The Neo-Hookean model accurately predicted the dynamic amplitude but failed to predict the initial compression of the cartilage, with a 10 times overprediction. The Ogden model provided the best results, with both the initial compression lying within one standard deviation of that observed in the validation data set, and the dynamic amplitude of the same order of magnitude. In conclusion, this study has found that the fast dynamic response of human AC is best represented by a third order Ogden model.
引用
收藏
页码:879 / 889
页数:11
相关论文
共 50 条
  • [41] Effects of introducing cultured human chondrocytes into a human articular cartilage explant model
    Charles Secretan
    Keith M. Bagnall
    Nadr M. Jomha
    Cell and Tissue Research, 2010, 339 : 421 - 427
  • [42] A numerical model to study mechanically induced initiation and progression of damage in articular cartilage
    Hosseini, S. M.
    Wilson, W.
    Ito, K.
    van Donkelaar, C. C.
    OSTEOARTHRITIS AND CARTILAGE, 2014, 22 (01) : 95 - 103
  • [43] Development of numerical model for ballistic resistance evaluation of combat helmet and experimental validation
    Rodriguez-Millan, M.
    Ito, T.
    Loya, J. A.
    Olmedo, A.
    Miguelez, M. H.
    MATERIALS & DESIGN, 2016, 110 : 391 - 403
  • [44] Optimizing Thermal Processing of Broccoli: Model Development, Numerical Simulation, Experimental Validation
    Pero, Milad
    Kiani, Hossein
    Skara, Torstein
    Skipnes, Dagbjorn
    Askari, Gholamreze
    INTERNATIONAL JOURNAL OF FOOD ENGINEERING, 2019, 15 (11-12)
  • [45] KTP LASER TISSUE ABLATION: DEVELOPMENT AND EXPERIMENTAL VALIDATION OF A NEW NUMERICAL MODEL
    Elkhalil, Hossam
    Akkin, Taner
    Bischof, John
    LASERS IN SURGERY AND MEDICINE, 2010, : 14 - 15
  • [46] Biofabrication of human articular cartilage: a path towards the development of a clinical treatment
    Onofrillo, Carmine
    Duchi, Serena
    O'Connell, Cathal D.
    Blanchard, Romane
    O'Connor, Andrea J.
    Scott, Mark
    Wallace, Gordon G.
    Choong, Peter F. M.
    Di Bella, Claudia
    BIOFABRICATION, 2018, 10 (04)
  • [47] Development of a numerical model for biomass packed bed pyrolysis based on experimental validation
    Borello, D.
    Cedola, L.
    Frangioni, G. V.
    Meloni, R.
    Venturini, P.
    De Filippis, P.
    de Caprariis, B.
    APPLIED ENERGY, 2016, 164 : 956 - 962
  • [48] Development of an Electromechanical Grade to Assess Human Knee Articular Cartilage Quality
    Sim, Sotcheadt
    Hadjab, Insaf
    Garon, Martin
    Quenneville, Eric
    Lavigne, Patrick
    Buschmann, Michael D.
    ANNALS OF BIOMEDICAL ENGINEERING, 2017, 45 (10) : 2410 - 2421
  • [49] Development of an Electromechanical Grade to Assess Human Knee Articular Cartilage Quality
    Sotcheadt Sim
    Insaf Hadjab
    Martin Garon
    Eric Quenneville
    Patrick Lavigne
    Michael D. Buschmann
    Annals of Biomedical Engineering, 2017, 45 : 2410 - 2421
  • [50] The expression of chondroitin sulphate glycosaminoglycans in the development of human foetal articular cartilage
    Li, S.
    Cao, J.
    Xue, R.
    Hayes, A. J.
    Caterson, B.
    Hughes, C. E.
    INTERNATIONAL JOURNAL OF EXPERIMENTAL PATHOLOGY, 2013, 94 (05) : A5 - A5