Mechanical analysis of the improved superelastic Ni-Ti alloy wire using the orthodontic simulator with high-precision sensors

被引:2
|
作者
Mikami, Naoaki [1 ]
Yonemitsu, Ikuo [1 ]
Takemura, Hiroshi [2 ]
Kondou, Mark [2 ]
Soga, Kouhei [3 ]
Suga, Kazuhiro [4 ]
Kanno, Zuisei [1 ]
Lai, WeiJen [1 ,5 ]
Uo, Motohiro [6 ]
Ono, Takashi [1 ]
机构
[1] Tokyo Med & Dent Univ TMDU, Grad Sch Med & Dent Sci, Dept Orthodont Sci, 1-5-45 Yushima,Bunkyo Ku, Tokyo 1138510, Japan
[2] Tokyo Univ Sci, Fac Sci & Engn, Dept Mech Engn, 2641 Yamazaki, Noda, Chiba 2788510, Japan
[3] Tokyo Univ Sci, Fac Adv Engn, Dept Mat Sci & Technol, 6-3-1 Niijuku,Katsushika Ku, Tokyo 1258585, Japan
[4] Kogakuin Univ, Fac Engn, Dept Mech Engn, 1-24-2 Nishi Shinjuku,Shinjuku Ku, Tokyo 1638677, Japan
[5] Natl Taiwan Univ, Sch Dent, Dept Dent, 1 Chang Te St, Taipei City 10048, Taiwan
[6] Tokyo Med & Dent Univ TMDU, Grad Sch Med & Dent Sci, Dept Adv Biomat, 1-5-45 Yushima,Bunkyo Ku, Tokyo 1138510, Japan
基金
日本学术振兴会;
关键词
Orthodontics; Orthodontic measurement system; 6-Axis sensor; Treatment mechanics; FORCE SYSTEM; V-BENDS;
D O I
10.1016/j.jmbbm.2023.105861
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: The authors have been using improved superelastic Nickel-Titanium alloy wire (ISW) to close and align extraction spaces simultaneously, instead of separately using rigid wires for closing extraction spaces and Ni-Ti alloy wires for leveling and aligning. ISW has a low stiffness, which makes it challenging to generate sufficient moments. This study aimed to demonstrate the forces and moments exerted on adjacent brackets using an or-thodontic simulator (OSIM) attached to a high-precision 6-axis sensor. Materials and methods: In experiment 1, a 0.016 x 0.022-inch ISW, stainless steel (SS) wire, and beta-titanium wires were ligatured into the two brackets. The 0.018 x 0.025-inch slot self-ligating brackets were bonded to two simulated teeth at the same height, and the experiment was conducted using the high-precision OSIM. The distance between the brackets was 10 mm, the V-bend angles of the installed wires were 10 degrees, 20 degrees, 30 degrees, and 40 degrees, and the apex position was set at the center of the bracket. In experiment 2, 6.0-and 9.0-mm long elastomeric chains were placed on the same brackets as in Experiment 1 to measure forces and moments. The distance be-tween the brackets was increased by 1.0 mm from 6.0 to 15.0 mm. Both experiments were conducted in a 37 degrees C thermostatic chamber similar to the oral environment. Results and discussion: In experiment 1, we measured moments on both sides for all the wires. As the V-bend angle increased, the absolute values of the moments also increased. With a V-bend angle of 10 degrees, there was a significant (p < 0.05) difference in the moment generated in the left and right brackets among the three wire types. In the ISW,-1.67 +/- 0.38 N center dot mm was generated in the left bracket, while 0.38 +/- 0.26 N center dot mm was generated in the right bracket at 10 degrees. At 20 degrees,-1.77 +/- 0.69 N center dot mm was generated in the left bracket, while 2.37 +/- 0.94 N center dot mm was generated in the right bracket. At 30 degrees,-2.98 +/- 0.49 N center dot mm was generated in the left bracket, while 3.25 +/- 0.32 N center dot mm was generated in the right bracket. Moreover, at 40 degrees,-3.96 +/- 0.58 N center dot mm was generated in the left bracket, while 3.55 +/- 0.53 N center dot mm was generated in the right bracket. Furthermore, in experiment 2, the moments increased in proportion to the increase in distance between the centers of the two brackets. Absolute values of the moments were approximately equal for the left and right brackets. The 6.0-mm elastomeric chain generated a minimum force of-0.09 +/- 0.05 N in the left direction when the distance between brackets was 6.0 mm, while a maximum of 1.24 +/- 0.3 N when the distance between brackets was 12 mm in the right bracket. In the left bracket, minimum and maximum forces of-0.09 +/- 0.07 and 1.3 +/- 0.4 N were generated in the right direction, respectively. The 9.0-mm elastomeric chain generated a minimum force of 0.03 +/- 0.07 N in the left direction when the distance between brackets was 9.0 mm, while a maximum of 1.3 +/- 0.1 N when the distance between brackets was 15 mm in the right bracket. In the left bracket, minimum and maximum forces of 0.05 +/- 0.06 and 0.98 +/- 0.2 N were generated in the right direction, respectively. Conclusion: Mechanical data of the ISW have been collected in the study, which was previously difficult to perform owing to the low stiffness of the wire. It is suggested that the ISW can provide sufficient moments with the addition of V-bends to close the space by bodily movement.
引用
收藏
页数:6
相关论文
共 48 条
  • [1] Mechanical analysis of the improved superelastic Ni-Ti alloy wire using the orthodontic simulator with high-precision sensors (vol 142, 105861, 2023)
    Mikami, Naoaki
    Yonemitsu, Ikuo
    Takemura, Hiroshi
    Kondou, Mark
    Soga, Kohei
    Suga, Kazuhiro
    Kanno, Zuisei
    Weijen, Lai
    Uo, Motohiro
    Ono, Takashi
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2023, 147
  • [2] The Improved Superelastic Ni-Ti Alloy Wire in Orthodontic Treatment: Characteristics and Clinical Application
    Yonemitsu, Ikuo
    Ozaki, Shusaku
    Ono, Takashi
    SEMINARS IN ORTHODONTICS, 2023, 29 (01) : 43 - 50
  • [3] Mechanical characterisation of orthodontic superelastic Ni-Ti wires
    Arrigoni, M
    Auricchio, F
    Cacciafesta, V
    Petrini, L
    Pietrabissa, R
    JOURNAL DE PHYSIQUE IV, 2001, 11 (PR8): : 577 - 582
  • [4] STUDY OF MECHANICAL, FATIGUE AND CORROSION PROPERTIES OF THE SUPERELASTIC Ni-Ti ALLOY
    Vojtech, Dalibor
    Kubasek, Jiri
    Voderova, Milena
    Seda, Petra
    Michalcova, Alena
    METAL 2011: 20TH ANNIVERSARY INTERNATIONAL CONFERENCE ON METALLURGY AND MATERIALS, 2011, : 991 - 997
  • [5] Stiffness in bending of a superelastic Ni-Ti orthodontic wire as a function of cross-sectional dimension
    Garrec, P
    Jordan, L
    ANGLE ORTHODONTIST, 2004, 74 (05) : 691 - 696
  • [6] Corrosion and Mechanical Degradation of Ni-Ti Superelastic Alloy in Neutral Fluoride Solution
    Toshio Ogawa
    Hirokaze Takada
    Kuniaki Maruoka
    Journal of Materials Engineering and Performance, 2018, 27 : 4010 - 4015
  • [7] Corrosion and Mechanical Degradation of Ni-Ti Superelastic Alloy in Neutral Fluoride Solution
    Ogawa, Toshio
    Takada, Hirokaze
    Maruoka, Kuniaki
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2018, 27 (08) : 4010 - 4015
  • [8] BENDING PROPERTIES AND TRANSFORMATION TEMPERATURES OF HEAT-TREATED NI-TI ALLOY WIRE FOR ORTHODONTIC APPLIANCES
    YONEYAMA, T
    DOI, H
    HAMANAKA, H
    YAMAMOTO, M
    KURODA, T
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (03): : 399 - 402
  • [9] Mechanical properties and the microstructure of Ni-Ti alloy at high strain rate
    Yang, Shengnan
    Yang, Suyuan
    Zhang, Xiao
    Wu, Qiong
    Xiyou Jinshu Cailiao Yu Gongcheng/Rare Metal Materials and Engineering, 2016, 45 (11): : 2847 - 2850
  • [10] Mechanical Properties and the Microstructure of Ni-Ti Alloy at High Strain Rate
    Yang Shengnan
    Yang Suyuan
    Zhang Xiao
    Wu Qiong
    RARE METAL MATERIALS AND ENGINEERING, 2016, 45 (11) : 2847 - 2850