Diagnostic Accuracy of Global Longitudinal Strain for Detecting Exercise Intolerance in Patients with Ischemic Heart Disease

被引:2
|
作者
Zhang, Sisi [1 ]
Liu, Yujian [1 ]
Jiang, Luying [1 ,2 ]
Wang, Zhaozhao [1 ]
Liu, Wanjun [1 ]
Zuo, Houjuan [1 ]
机构
[1] Huazhong Univ Sci & Technol, Tongji Hosp, Tongji Med Coll, Dept Internal Med,Div Cardiol, Wuhan 430030, Peoples R China
[2] Hubei Key Lab Genet & Mol Mech Cardiol Disorders, Wuhan 430030, Peoples R China
关键词
2D speckle-tracking echocardiography; global longitudinal strain; cardiopulmonary exercise testing; exercise intolerance; ischemic heart disease; CORONARY-ARTERY-DISEASE; WALL-MOTION; MYOCARDIAL-INFARCTION; SCIENTIFIC STATEMENT; STABLE ANGINA; 2D STRAIN; CAPACITY; ECHOCARDIOGRAPHY; REST; ASSOCIATION;
D O I
10.3390/jcdd10010010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Global longitudinal strain (GLS) is a sensitive and reproducible predictive factor in patients with ischemic heart disease (IHD), although its correlation with exercise tolerance is unknown. We aimed to identify the correlation between global longitudinal strain (GLS) and cardiopulmonary exercise testing (CPX) parameters and assess the prognostic implications and accuracy of GLS in predicting exercise intolerance in populations with ischemic heart disease (IHD) using CPET criteria. Methods: Prospectively, 108 patients with IHD underwent CPX and 2D speckle-tracking echocardiography. Correlation between GLS and multiple CPX variables was assessed using Spearman's correlation analysis and univariate regression analysis. A receiver operating characteristic (ROC) curve analysis was performed on GLS to detect exercise intolerance. Results: GLS was correlated with peak oxygen uptake (peak VO2; r = -0.438, p = 0.000), %PPeak VO2 (-0.369, p = 0.000), peak metabolic equivalents (METs@peak; r = -0.438, p < 0.01), and the minute ventilation-carbon dioxide production (VE/VCO2) slope (r = 0.257, p < 0.01). Weak-to-moderate correlations were also identified for the respiratory exchange rate at the anaerobic threshold (RER@AT), end-tidal carbon dioxide at the anaerobic threshold (PETCO2@AT), oxygen consumption at the anaerobic threshold (VO2@AT), carbon dioxide production at the anaerobic threshold (VCO2@AT), and metabolic equivalents at the anaerobic threshold (METs@AT; p < 0.01). On multivariate analysis, the results showed that age, the BMI, and GLS are independent predictors for reduced exercise capacity in patients with IHD (p < 0.01). The area under the ROC curve value of GLS for identifying patients with a peak VO2 of <14 mL/kg/min was 0.73 (p = 0.000). Conclusion: As a sensitive echocardiographic assessment of patients with ischemic heart disease, global longitudinal strain is an independent predictor of reduced exercise capacity and has a sensitivity of 74.2% and a specificity of 66.7% to detect exercise intolerance.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Right ventricular dysfunction is associated with exercise intolerance and poor prognosis in ischemic heart disease
    Tajima, Miyu
    Nakayama, Atsuko
    Uewaki, Reina
    Mahara, Keitaro
    Isobe, Mitsuaki
    Nagayama, Masatoshi
    HEART AND VESSELS, 2019, 34 (03) : 385 - 392
  • [22] The diagnostic value of exercise testing in patients with exercise intolerance
    Ernsting, C. G.
    Visser, G.
    van Hasselt, P. M.
    Prinsen, B. H. C. M. T.
    Hulzebos, H. J.
    Takken, T.
    JOURNAL OF INHERITED METABOLIC DISEASE, 2007, 30 : 140 - 140
  • [23] Global longitudinal strain correlates to reduced exercise capacity in heart failure patients with preserved ejection fraction
    Hasselberg, N.
    Haugaa, K. H.
    Sarvari, S. I.
    Smiseth, O. A.
    Andreassen, A. K.
    Edvardsen, T.
    EUROPEAN HEART JOURNAL, 2013, 34 : 199 - 199
  • [24] Exercise Intolerance in Patients With Heart Failure
    Del Buono, Marco Giuseppe
    Arena, Ross
    Borlaug, Barry A.
    Carbone, Salvatore
    Canada, Justin M.
    Kirkman, Danielle L.
    Garten, Ryan
    Rodriguez-Miguelez, Paula
    Guazzi, Marco
    Lavie, Carl J.
    Abbate, Antonio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2019, 73 (17) : 2209 - 2225
  • [25] The use of exercise impedance cardiography as a screening test for detecting ischemic heart disease
    Klainman, E
    Bott-Kaner, G
    Stanetzky, M
    Shniper, I
    Fink, G
    PROGRESS IN CORONARY ARTERY DISEASE, 2005, : 157 - 160
  • [26] SUBMAXIMAL EXERCISE ELECTROCARDIOGRAPHIC TEST AS A METHOD OF DETECTING OCCULT ISCHEMIC HEART DISEASE
    SPANGLER, RD
    HORMAN, MJ
    MILLER, SW
    ROTENBERG, DA
    BIRNHOLZ, JC
    SIMMONS, RL
    WESTURA, EE
    FOX, SM
    AMERICAN HEART JOURNAL, 1970, 80 (06) : 752 - +
  • [27] LONGITUDINAL CHANGES IN LACTATE THRESHOLD AND MAXIMAL OXYGEN UPTAKE OF PATIENTS WITH ISCHEMIC HEART DISEASE ENGAGING IN EXERCISE
    Nakagaichi, M.
    Hayashi, Y.
    Sakai, T.
    Shigematsu, R.
    Hayakawa, Y.
    Takeda, M.
    Tanaka, K.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (05): : S259 - S259
  • [28] Exercise intolerance in adults with congenital heart disease
    Dimopoulos, Konstantinos
    Diller, Gerhard-Paul
    Piepoli, Massimo F.
    Gatzoulis, Michael A.
    CARDIOLOGY CLINICS, 2006, 24 (04) : 641 - +
  • [29] THE RATIO OF ENDOCARDIAL LONGITUDINAL STRAIN JUST AFTER EXERCISE STRESS TO THAT AT REST IS USEFUL IN DETECTING FUNCTIONAL MYOCARDIAL ISCHEMIC SEGMENTS IN STABLE PATIENTS WITH CORONARY ARTERY DISEASE
    Nishi, Takeshi
    Funabashi, Nobusada
    Ozawa, Koya
    Takahara, Masayuki
    Takaoka, Hiroyuki
    Fujimoto, Yoshihide
    Kobayashi, Yoshio
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 67 (13) : 1606 - 1606
  • [30] Global longitudinal systolic strain is able to differentiate between non-ischemic and ischemic cardiomyopathy among patients with systolic heart failure
    Sengelov, M.
    Biering-Sorensen, T.
    Jorgensen, P. G.
    Bruun, N. E.
    Olsen, F. J.
    Fritz-Hansen, T.
    Jensen, J. S.
    EUROPEAN HEART JOURNAL, 2015, 36 : 144 - 144