Is Patient-Specific Instrumentation Accurate and Necessary for Open-Wedge High Tibial Osteotomy? A Meta-Analysis

被引:9
|
作者
Pang, Ran [1 ]
Jiang, Zhaohui [1 ]
Xu, Chunlei [1 ]
Shi, Wei [1 ]
Zhang, Xinglong [1 ]
Wan, Xin [1 ]
Bahat, Daniel [2 ]
Li, Hui [1 ,3 ]
Senatov, Fedor [4 ]
Bulygina, Inna [4 ]
Wang, Hu [5 ]
Zhang, Huafeng [1 ,6 ]
Li, Zhijun [1 ,6 ]
机构
[1] Tianjin Med Univ Gen Hosp, Dept Orthopaed, Tianjin, Peoples R China
[2] Cleveland Clin, Dept Orthopaed, Cleveland, OH USA
[3] Natl Univ Sci & Technol MISIS, Ctr Biomed Engn, Moscow, Russia
[4] Tianjin Vocat Coll Sports, Dept Phys Hlth Care & Rehabil, Tianjin, Peoples R China
[5] ITCWM Nankai Hosp, Dept Orthopaed, Tianjin Hosp, Tianjin, Peoples R China
[6] Tianjin Med Univ Gen Hosp, Dept Orthopaed, Tianjin 300052, Peoples R China
基金
中国国家自然科学基金;
关键词
High tibial osteotomy; Meta-analysis; Osteoarthritis; Patient-specific cutting guides; Patient-specific instrumentation; Three-dimensional; CUTTING GUIDES; KNEE; SLOPE;
D O I
10.1111/os.13483
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this meta-analysis was to identify if patient-specific instrumentation (PSI) could increase the accuracy of the correction in high tibial osteotomy (HTO) and to explore the assessment indices and the necessity of using a PSI in HTO. A systematic search was carried out using online databases. A total of 466 patients were included in 11 papers that matched the inclusion criteria. To evaluate the accuracy of PSI-assisted HTO, the weight bearing line ratio (WBL%), hip-knee-ankle angle (HKA), mechanical medial proximal tibial angle (mMPTA), and posterior tibial slope angle (PTSA) were measured preoperatively and postoperatively and compared to the designed target values. Statistical analysis was performed after strict data extraction with Review Manager (version 5.4). Significant differences were detected in WBL% (MD = -36.41; 95% CI: -42.30 to -30.53; p < 0.00001), HKA (MD = -9.95; 95% CI: -11.65 to -8.25; p < 0.00001), and mMPTA (MD = -8.40; 95% CI:-10.27 to -6.53; p < 0.00001) but not in PTSA (MD = 0.34; 95% CI: -0.59 to 1.27; p = 0.47) between preoperative and postoperative measurements. There was no significant difference between the designed target values and the postoperative correction values of HKA (MD = 0.14; 95% CI: -0.19 to 0.47; p = 0.41) or mMPTA (MD = 0.11; 95% CI -0.34 to 0.55; p = 0.64). The data show that 3D-based planning of PSI for HTO is both accurate and safe. WBL%, HKA, and mMPTA were the optimal evaluation indicators of coronal plane correction. Sagittal correction is best evaluated by the PTSA. The present study reports that PSI is accurate but not necessary in typical HTO.
引用
收藏
页码:413 / 422
页数:10
相关论文
共 50 条
  • [31] A new technique of autologous bone grafting for open-wedge high tibial osteotomy
    Gong, Yongchao
    Jin, Lin
    Wang, Yanwei
    Liu, Boxu
    Shen, Pengfei
    Zhang, Zhiang
    Yuwen, Peizhi
    Zhao, Kuo
    Ma, Lijie
    Chen, Wei
    Zhang, Yingze
    FRONTIERS IN SURGERY, 2024, 11
  • [32] Closed-wedge high tibial osteotomy is more advantageous to maintain the correction than open-wedge high tibial osteotomy in osteopenic patients
    Song, Sang Jun
    Yoon, Kyoung Ho
    Kim, Kang Il
    Park, Cheol Hee
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2023, 31 (04) : 1563 - 1570
  • [33] Closed-wedge high tibial osteotomy is more advantageous to maintain the correction than open-wedge high tibial osteotomy in osteopenic patients
    Sang Jun Song
    Kyoung Ho Yoon
    Kang Il Kim
    Cheol Hee Park
    Knee Surgery, Sports Traumatology, Arthroscopy, 2023, 31 : 1563 - 1570
  • [34] Tranexamic acid is effective for blood management in open-wedge high tibial osteotomy
    Kim, Kang-Il
    Kim, Hwan Jin
    Kim, Gi Beom
    Bae, Seong Hae
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2018, 104 (07) : 1003 - 1007
  • [35] No correction angle loss with stable plates in open-wedge high tibial osteotomy
    Min Kyu Kim
    Jeong Ku Ha
    Dhong Won Lee
    Sang Wook Nam
    Jin Goo Kim
    Yong Seuk Lee
    Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 1999 - 2006
  • [36] Reliability of the imaging software in the preoperative planning of the open-wedge high tibial osteotomy
    Lee, Yong Seuk
    Kim, Min Gyu
    Byun, Hae Won
    Kim, Sang Bum
    Kim, Jin Goo
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (03) : 846 - 851
  • [37] No correction angle loss with stable plates in open-wedge high tibial osteotomy
    Kim, Min Kyu
    Ha, Jeong Ku
    Lee, Dhong Won
    Nam, Sang Wook
    Kim, Jin Goo
    Lee, Yong Seuk
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (07) : 1999 - 2006
  • [38] Tranexamic Acid Is Beneficial to Patients Undergoing Open-Wedge High Tibial Osteotomy
    Chen, De-Sheng
    Zhu, Jia-Wang
    Wang, Tong-Fu
    Zhu, Bo
    Feng, Cai-Hong
    BIOMED RESEARCH INTERNATIONAL, 2020, 2020
  • [39] Early full weight bearing is safe in open-wedge high tibial osteotomy
    Brinkman, Justus-Martijn
    Luites, Joan W. H.
    Wymenga, Ate B.
    van Heerwaarden, Ronald J.
    ACTA ORTHOPAEDICA, 2010, 81 (02) : 193 - 198
  • [40] Change in adduction moment following medial open wedge high tibial osteotomy: a meta-analysis
    Jun-Ho Kim
    Hyun-Jung Kim
    Haluk Celik
    Joo-Hwan Kim
    Dae-Hee Lee
    BMC Musculoskeletal Disorders, 20