Resilience-oriented placement of multi-carrier microgrids in power systems with switchable transmission lines

被引:5
|
作者
Jordehi, A. Rezaee [1 ,5 ]
Mansouri, Seyed Amir [2 ]
Tostado-Veliz, Marcos [3 ]
Ahmarinejad, Amir [4 ]
Jurado, Francisco [3 ]
机构
[1] Islamic Azad Univ, Dept Elect Engn, Rasht Branch, Rasht, Iran
[2] Comillas Pontifical Univ, Inst Res Technol IIT, ICAI Sch Engn, Madrid 28015, Spain
[3] Univ Jaen, Dept Elect Engn, Linares 23700, Spain
[4] Islamic Azad Univ, Dept Elect Engn, Cent Tehran Branch, Tehran, Iran
[5] Islamic Azad Univ, Rasht Branch, Rasht, Iran
基金
英国工程与自然科学研究理事会;
关键词
Power system resilience; Microgrids; Transmission switching; Heat-power-hydrogen microgrids;
D O I
10.1016/j.ijhydene.2023.07.277
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Extreme events such as floods, hurricanes, earthquakes, and wildfires pose significant threats to the uninterrupted supply of electricity to consumers, as they can cause the failure of numerous power system components. The resilience of a power system is defined by its ability to withstand extreme events and continue meeting demand. While the placement of multi-carrier microgrids (MGs) in power systems can impact resilience, the literature lacks research on resilience-oriented placement. This paper aims to address this gap by proposing a resilience-oriented placement strategy for multi-carrier MGs, utilizing switchable transmission lines to enhance the resilience of power systems. The study focuses on a heat-power-hydrogen MG that obtains gas from a gas network, exchanges power with the main power system, and incorporates combined heat and power (CHP), electrolyzer, and thermal storage. The developed model employs a stochastic mixedinteger linear programming (MILP) approach, ensuring the attainment of the global optimum. Resilience is evaluated using the metric of expected load not supplied (ELNS). The results demonstrate that when the bus connected to the MG is isolated, the MG generates electricity through its CHP unit to meet local demand, reducing the total demand shed in the power system and improving system resilience. Specifically, the MG reduces ELNS from 4955.48 MWh to 2356.64 MWh, indicating a remarkable 52% improvement in ELNS. Furthermore, the study shows that transmission line switching further decreases ELNS from 2356.64 MWh to 848.68 MWh. Several experiments are conducted to analyze the sensitivity of power system resilience to the number of MGs, the MG-power system exchange limit, and the limit on gas import from the gas network. (c) 2023 Hydrogen Energy Publications LLC. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:175 / 185
页数:11
相关论文
共 50 条
  • [21] Optimization of transmission lines congestion management in integrated electricity and natural gas multi-carrier energy systems
    Khoshbouy, Morteza
    Kazemzadeh, Rasool
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2024, 18 (04) : 855 - 870
  • [22] Experimental Measurements of Multi-carrier Power Line Communication Systems
    Slacik, Jan
    Mlynek, Petr
    Fujdiak, Radek
    Dobesova, Katerina
    2017 40TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2017, : 91 - 96
  • [23] Dynamic Power Allocation for Downlink Multi-Carrier NOMA Systems
    Liu, Fei
    Petrova, Marina
    IEEE COMMUNICATIONS LETTERS, 2018, 22 (09) : 1930 - 1933
  • [24] Optimization of Multi-Carrier Frequency Diverse Array for Wireless Power Transmission
    Yang, Yu-Qian
    Wang, Hao
    Gu, Si-Qi
    2018 ASIA-PACIFIC MICROWAVE CONFERENCE PROCEEDINGS (APMC), 2018, : 43 - 45
  • [25] An Efficient Bit and Power Allocation Algorithm for Multi-Carrier Systems
    Qing, Huo Yong
    Jiao, Peng Qi Cong Mou
    2009 INTERNATIONAL CONFERENCE ON COMMUNICATIONS, CIRCUITS AND SYSTEMS PROCEEDINGS, VOLUMES I & II: COMMUNICATIONS, NETWORKS AND SIGNAL PROCESSING, VOL I/ELECTRONIC DEVICES, CIRUITS AND SYSTEMS, VOL II, 2009, : 100 - 103
  • [26] A peak power reduction scheme with adaptive transmit power control for multi-carrier transmission
    Muta, O
    Akaiwa, Y
    1999 IEEE 49TH VEHICULAR TECHNOLOGY CONFERENCE, VOLS 1-3: MOVING INTO A NEW MILLENIUM, 1999, : 2144 - 2148
  • [27] Peak power reduction scheme with adaptive transmit power control for multi-carrier transmission
    Kyushu Univ, Fukuoka-shi, Japan
    IEEE Veh Technol Conf, (2144-2148):
  • [28] Carrier communication over transmission lines in power systems
    Ishkin, V.Kh.
    Mikutskij, G.V.
    Khkarin, Yu.P.
    Elektrichestvo, 1992, (08): : 7 - 11
  • [29] Editorial: Data-based resilience-oriented planning and operation of multi-energy systems
    Li, Zhengmao
    Guerrero, Josep M.
    Shahidehpour, Mohammad
    Lo, Edmond Y. M.
    Lei, Shunbo
    FRONTIERS IN ENERGY RESEARCH, 2023, 11
  • [30] Resilience-oriented optimal post-disruption reconfiguration for coupled traffic-power systems
    Wang, Hongping
    Fang, Yi-Ping
    Zio, Enrico
    RELIABILITY ENGINEERING & SYSTEM SAFETY, 2022, 222