Advanced Fault Ride-Through Operation Strategy Based on Model Predictive Control for High Power Wind Turbine

被引:2
|
作者
Catalan, Pedro [1 ]
Wang, Yanbo [2 ]
Arza, Joseba [3 ]
Chen, Zhe [2 ]
机构
[1] Ingeteam Power Technol, Bilbao 48170, Spain
[2] Aalborg Univ, Energy Technol, DK-9220 Aalborg, Denmark
[3] Ingeteam R&D Europe, Zamudio 48170, Spain
关键词
Fault ride-through; grid fault; high power wind turbine; model predictive control; power converter; CONVERTERS; STABILITY;
D O I
10.1109/TSTE.2023.3302770
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This article presents an advanced fault ride-through control strategy based on model predictive control (MPC) of high-power wind turbine (WT), which is able to provide voltage support for power grid under symmetrical and asymmetrical grid faults. An optimal cost function is first established to realize multi-objective control of wind power converter, considering current regulation, neutral-point voltage balance, and switching frequency control. The flexible positive and negative sequence control (FPNSC) method is applied to generate the current references complying with converter current and voltage limitations. Simulation and hardware-in-the-loop experimental verification are implemented to validate the effectiveness of the proposed fault-ride through operation strategy. The verification results show that the proposed strategy is able to effectively support voltage and implement fault ride-through (FRT) during grid faults with optimized neutral-point voltage and average switching frequency. The proposed MPC strategy can address different fault conditions with good adaptivity. It thus enhances the operation performance of high-power WT during faults events.
引用
收藏
页码:513 / 526
页数:14
相关论文
共 50 条
  • [21] A coordination control between energy storage based DVR and wind turbine for continuous fault ride-through
    Chen, Xunjun
    Geng, Guangchao
    Jiang, Quanyuan
    IET RENEWABLE POWER GENERATION, 2024, 18 (14) : 2560 - 2574
  • [22] DC fault ride-through control strategy of wind power integrated DC transmission system based on modified MMC
    Jiang S.
    Zhang L.
    Li G.
    Xin Y.
    Wang Z.
    Dianli Zidonghua Shebei/Electric Power Automation Equipment, 2021, 41 (12): : 27 - 35
  • [23] Low Voltage Ride-through Control Strategy for DFIG-based Wind Turbine Based on Disturbance Attenuation
    Zhang R.
    Qin B.
    Li H.
    Liu W.
    Chen J.
    Qin, Boyu (qinboyu@xjtu.edu.cn), 1600, Automation of Electric Power Systems Press (44): : 112 - 120
  • [24] Modelling wind turbine-generators for fault ride-through studies
    Salman, SK
    Badrzadeh, B
    Penman, J
    UPEC 2004: 39th International Universitities Power Engineering Conference, Vols 1-3, Conference Proceedings, 2005, : 634 - 638
  • [25] Wind Turbine Controller Design for improved Fault Ride-Through Ability
    Zhang, Fan
    PROCEEDINGS OF THE 2016 5TH INTERNATIONAL CONFERENCE ON ENERGY AND ENVIRONMENTAL PROTECTION (ICEEP 2016), 2016, 98 : 45 - 55
  • [26] Fault ride-through control strategy of wind farm integrated with VSC-HVDC
    Wang, Y., 1600, China Machine Press (28):
  • [27] A coordinated control strategy for fault ride-through of wind farm integration based on VSC-HVDC
    Li, Qi
    Song, Qiang
    Liu, Wenhua
    Rao, Hong
    Xu, Shukai
    Li, Xiaolin
    Dianwang Jishu/Power System Technology, 2014, 38 (07): : 1739 - 1745
  • [28] Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    Ran, Li
    Xiang, Dawei
    Tavner, Peter J.
    Yang, Shunchang
    2006 POWER ENGINEERING SOCIETY GENERAL MEETING, VOLS 1-9, 2006, : 1623 - 1623
  • [29] Coordinated Control of SMES and DVR for Improving Fault Ride-Through Capability of DFIG-based Wind Turbine
    Bouaziz, Fatma
    Masmoudi, Abdelkarim
    Abdelkafi, Achraf
    Krichen, Lotfi
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2022, 12 (01): : 359 - 371
  • [30] Control of a doubly fed induction generator in a wind turbine during grid fault ride-through
    Xiang, Dawei
    Ran, Li
    Tavner, Peter J.
    Yang, Shunchang
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (03) : 652 - 662