Experimental and numerical investigation into locally corroded circular concrete-filled steel tubular stub columns strengthened by CFRP

被引:8
|
作者
Huang, Haijia [1 ,2 ]
Guo, Lanhui [2 ,3 ]
Zhao, Ou [4 ]
Gao, Shan [2 ,3 ]
机构
[1] Nanchang Univ, Sch Infrastruct Engn, Nanchang 330031, Peoples R China
[2] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Peoples R China
[3] Harbin Inst Technol, Minist Ind & Informat Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disaste, Harbin 150090, Peoples R China
[4] Nanyang Technol Univ, Sch Civil & Environm Engn, Singapore, Singapore
基金
中国国家自然科学基金;
关键词
Concrete-filled steel tube (CFST); Local corrosion; carbon fiber reinforced polymer (CFRP); Artificial notch; Axial behavior; PITTING CORROSION; CFST COLUMNS; SUSTAINED LOAD; HOLD FRAMES; BEHAVIOR;
D O I
10.1016/j.tws.2023.111174
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Concrete-filled steel tube (CFST) is vulnerable to corrosion in service, especially local corrosion. Nevertheless, limited work has been conducted on the behaviors and strengthening methods of locally corroded CFSTs. This paper presents experimental and numerical investigations into the behavior of locally corroded CFST stub columns and locally corroded CFST stub columns strengthened by carbon fiber reinforced polymer (CFRP). Tests were conducted on thirteen specimens with local corrosion of steel tubes simulated by means of artificial notches, and the notch length and number of CFRP layers were chosen as test parameters. The test results revealed that the performance of the specimens strengthened by CFRP was significantly improved, compared with that of the unstrengthened specimens. The maximum compression resistance increment of the CFRP-strengthened specimens was up to 58.8%. Subsequently, finite element (FE) models were developed and verified by the experimental results. Based on the FE models, parametric analyzes were conducted to investigate the axial behavior of locally corroded circular CFST stub columns strengthened by CFRP. The parametric analysis results indicated that CFRP can compensate for the loss of confinement effect of steel tube caused by local corrosion. In addition, when the hoop force provided by CFRP is equal to that provided by the yield stress of steel tube, the compression resistance of locally corroded CFST stub columns strengthened by CFRP is even slightly higher than that of CFST stub columns without corrosion.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Axial loading behavior of CFRP strengthened concrete-filled steel tubular stub columns
    Tao, Zhong
    Han, Lin-Hai
    Zhuang, Jin-Ping
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2007, 10 (01) : 37 - 46
  • [2] Experimental investigation on concrete-filled stainless steel stiffened tubular stub columns
    Dabaon, M. A.
    El-Boghdadi, M. H.
    Hassanein, M. F.
    [J]. ENGINEERING STRUCTURES, 2009, 31 (02) : 300 - 307
  • [3] Experimental Investigation on Rectangular Inclined Concrete-Filled Steel Tubular Stub Columns
    Ren, Qingxin
    Mo, Yaqing
    Jia, Lianguang
    Liu, Hong
    [J]. FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 826 - 829
  • [4] Fire performance of concrete-filled steel tubular columns strengthened by CFRP
    Civionics Research Centre, University of Western Sydney, Penrith, NSW 2751, Australia
    不详
    不详
    [J]. Steel Compos. Struct., 4 (307-324):
  • [5] Fire performance of concrete-filled steel tubular columns strengthened by CFRP
    Tao, Zhong
    Wang, Zhi-Bin
    Han, Lin-Hai
    Uy, Brian
    [J]. STEEL AND COMPOSITE STRUCTURES, 2011, 11 (04): : 307 - 324
  • [6] Experimental and numerical investigations of square concrete-filled double steel tubular stub columns
    Ci, Junchang
    Ahmed, Mizan
    Jia, Hong
    Chen, Shicai
    Zhou, Daxing
    Hou, Liqun
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2021, 24 (11) : 2441 - 2456
  • [7] Experimental investigation on sea sand concrete-filled stainless steel tubular stub columns
    Liao, Fei-Yu
    Hou, Chao
    Zhang, Wei-Jie
    Ren, Jie
    [J]. JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2019, 155 : 46 - 61
  • [8] Behavior of Corroded Thin-Walled Concrete-Filled Steel Tubular Stub Columns
    Xue, Wen
    Chen, Ju
    Xie, Fang
    Ye, Changhu
    Liu, Chengbin
    [J]. BUILDINGS, 2022, 12 (04)
  • [9] Experimental investigation on the bamboo-concrete filled circular steel tubular stub columns
    Gan, D.
    Zhang, T.
    Zhou, X.
    He, Z.
    [J]. PROCEEDINGS OF THE 12TH INTERNATIONAL CONFERENCE ON ADVANCES IN STEEL-CONCRETE COMPOSITE STRUCTURES (ASCCS 2018), 2018, : 385 - 391
  • [10] Composite action of concrete-filled double circular steel tubular stub columns
    Wang, Liping
    Cao, Xing-xing
    Ding, Fa-xing
    Luo, Liang
    Sun, Yi
    Liu, Xue-mei
    Su, Hui-lin
    [J]. STEEL AND COMPOSITE STRUCTURES, 2018, 29 (01): : 77 - 90