Evaluation of the Malalignment Varus- Valgus in Total Knee Arthroplasty Designed for Deep Knee Flexion Used Knee Kinematic Motion Simulator

被引:0
|
作者
Triwardono, Joko [1 ]
Rokhmanto, Fendy [1 ]
Roberto, Rahadian [1 ]
Kartika, Ika [1 ]
Saragih, Agung Shamsuddin [2 ]
Whulanza, Yudan [2 ]
Shuib, Solehuddin [3 ]
Supriadi, Sugeng [2 ]
机构
[1] Natl Res & Innovat Agcy, Res Ctr Met, KST BJ Habibie, South Tangerang, Indonesia
[2] Univ Indonesia, Dept Mech Engn, Depok, Indonesia
[3] Univ Teknol MARA, Coll Engn, Sch Mech Engn, Shah Alam, Selangor, Malaysia
关键词
malalignment; hyperflexion; subluxations; dislocations; wear; polyethylene; PATIENT SATISFACTION; FAILURE; THICKNESS; COMPONENT; ALIGNMENT; FRACTURE; OUTCOMES; JOINT; POST;
D O I
10.4028/p-l6p55i
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Revision total knee arthroplasties cause performed aseptic loosening, instability, and polyethylene wear. Separation or removal of the femoral component has been observed and this has the potential to severely damage the polyethylene component. In most cases 90% of the patients examined experienced significant medial or lateral condylar lift at some stage during the gait cycle. Using the MRI, a normal knee has maximum lateral lift is approx. 6.7 mm and maximum medial lift is approx. 2.1 mm, when a varus strees applied at a 90 degrees knee flexion. Elevation of the lateral condyle due to valgus malalignment will distribute more contact force on the medial condyle. In this study, a polyethylene component of a posterior-stabilized right knee joint implant was developed to facilitate a high range of motion (ROM). Malalignment valgus was observed with the axes of knee motion joint implants were varied from 0 degrees, 2 degrees, 3 degrees to 5 and knee bend measurements at 30 degrees, 60 degrees, 90 degrees, 120 degrees, and 150 degrees of knee flexion. Using the knee kinematic motion simulator, the modified polyethylene component resulted in 0 degrees malalignment there is no gap of the femoral component with the polyethylene component, from 30 degrees to 150 degrees of knee flexion. At 2 degrees malalignment, the femoral component was raised by 0.5 mm at a 90 degrees to 150 degrees knee flexion and increased with increasing knee flexion. Maximum gap occurs at 5 degrees malalignment in the amount of 5 mm at 150 degrees of knee flexion. The aim of this study was therefore to evaluation malalignment valgus of the flexed knee using knee kinematic motion simulator, with reference to the tibiofemoral flexion gap. The result that the modified design is expected in an narrow down gap between femoral and polyethylene component used knee kinematic motion simulator, this accommodate deep knee flexion movement in daily activities and reduce the possibility of subluxation and dislocation at the polyethylene component during deep knee flexion. A wide gap between the femoral component and the polyethylene component and a significant amount of contact force in the medial condyle region might be the explanation for polyethylene component damage. It is expected that potential medial or lateral condylar lift at some stage during the gait cycle can be reduced.
引用
收藏
页码:119 / 130
页数:12
相关论文
共 50 条
  • [41] Varus-valgus balance and range of movement after total knee arthroplasty
    Matsuda, Y
    Ishii, Y
    Noguchi, H
    Ishii, R
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (06): : 804 - 808
  • [42] Improved knee flexion following high-flexion total knee arthroplasty
    Lionberger, David R.
    Eggers, Mitchell D.
    Brewer, Kathryn E.
    Fang, Li
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2012, 7
  • [43] Improved knee flexion following high-flexion total knee arthroplasty
    David R Lionberger
    Mitchell D Eggers
    Kathryn E Brewer
    Li Fang
    Journal of Orthopaedic Surgery and Research, 7
  • [44] In vivo kinematic evaluation and design considerations related to high flexion in total knee arthroplasty
    Argenson, JNA
    Scuderi, GR
    Komistek, RD
    Scott, WN
    Kelly, MA
    Aubaniac, JM
    JOURNAL OF BIOMECHANICS, 2005, 38 (02) : 277 - 284
  • [45] Varus and valgus stress tests after total knee arthroplasty with and without anesthesia
    Tadashi Tsukeoka
    Yoshikazu Tsuneizumi
    Archives of Orthopaedic and Trauma Surgery, 2016, 136 : 407 - 411
  • [46] Varus and valgus flexion laxity of total knee alignment methods in loaded cadaveric knees
    Romero, J
    Duronio, JF
    Sohrabi, A
    Alexander, N
    MacWilliams, BA
    Jones, LC
    Hungerford, DS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (394) : 243 - 253
  • [47] High flexion total knee arthroplasty
    Anz, Adam W.
    Jinnah, Riyaz
    CURRENT ORTHOPAEDIC PRACTICE, 2009, 20 (01): : 40 - 46
  • [48] Contralateral knee flexion predicts postoperative knee flexion in unilateral total knee arthroplasty: A retrospective study
    Kamenaga, Tomoyuki
    Hiranaka, Takafumi
    Okimura, Kenjiro
    Fujishiro, Takaaki
    Okamoto, Koji
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2022, 108 (05)
  • [49] Total knee arthroplasty with limitations of flexion
    Massin, P.
    Lautridou, C.
    Cappelli, M.
    Petit, A.
    Odri, G.
    Ducellier, F.
    Sabatier, C.
    Hulet, C.
    Canciani, J. P.
    Letenneur, J.
    Burdin, P.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2009, 95 (04) : S1 - S6
  • [50] Flexion contracture in total knee arthroplasty
    Bellemans, Johan
    Vandenneucker, Hilde
    Victor, Jan
    Vanlauwe, Johan
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) : 78 - 82