Evaluation of the Malalignment Varus- Valgus in Total Knee Arthroplasty Designed for Deep Knee Flexion Used Knee Kinematic Motion Simulator

被引:0
|
作者
Triwardono, Joko [1 ]
Rokhmanto, Fendy [1 ]
Roberto, Rahadian [1 ]
Kartika, Ika [1 ]
Saragih, Agung Shamsuddin [2 ]
Whulanza, Yudan [2 ]
Shuib, Solehuddin [3 ]
Supriadi, Sugeng [2 ]
机构
[1] Natl Res & Innovat Agcy, Res Ctr Met, KST BJ Habibie, South Tangerang, Indonesia
[2] Univ Indonesia, Dept Mech Engn, Depok, Indonesia
[3] Univ Teknol MARA, Coll Engn, Sch Mech Engn, Shah Alam, Selangor, Malaysia
关键词
malalignment; hyperflexion; subluxations; dislocations; wear; polyethylene; PATIENT SATISFACTION; FAILURE; THICKNESS; COMPONENT; ALIGNMENT; FRACTURE; OUTCOMES; JOINT; POST;
D O I
10.4028/p-l6p55i
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Revision total knee arthroplasties cause performed aseptic loosening, instability, and polyethylene wear. Separation or removal of the femoral component has been observed and this has the potential to severely damage the polyethylene component. In most cases 90% of the patients examined experienced significant medial or lateral condylar lift at some stage during the gait cycle. Using the MRI, a normal knee has maximum lateral lift is approx. 6.7 mm and maximum medial lift is approx. 2.1 mm, when a varus strees applied at a 90 degrees knee flexion. Elevation of the lateral condyle due to valgus malalignment will distribute more contact force on the medial condyle. In this study, a polyethylene component of a posterior-stabilized right knee joint implant was developed to facilitate a high range of motion (ROM). Malalignment valgus was observed with the axes of knee motion joint implants were varied from 0 degrees, 2 degrees, 3 degrees to 5 and knee bend measurements at 30 degrees, 60 degrees, 90 degrees, 120 degrees, and 150 degrees of knee flexion. Using the knee kinematic motion simulator, the modified polyethylene component resulted in 0 degrees malalignment there is no gap of the femoral component with the polyethylene component, from 30 degrees to 150 degrees of knee flexion. At 2 degrees malalignment, the femoral component was raised by 0.5 mm at a 90 degrees to 150 degrees knee flexion and increased with increasing knee flexion. Maximum gap occurs at 5 degrees malalignment in the amount of 5 mm at 150 degrees of knee flexion. The aim of this study was therefore to evaluation malalignment valgus of the flexed knee using knee kinematic motion simulator, with reference to the tibiofemoral flexion gap. The result that the modified design is expected in an narrow down gap between femoral and polyethylene component used knee kinematic motion simulator, this accommodate deep knee flexion movement in daily activities and reduce the possibility of subluxation and dislocation at the polyethylene component during deep knee flexion. A wide gap between the femoral component and the polyethylene component and a significant amount of contact force in the medial condyle region might be the explanation for polyethylene component damage. It is expected that potential medial or lateral condylar lift at some stage during the gait cycle can be reduced.
引用
收藏
页码:119 / 130
页数:12
相关论文
共 50 条
  • [1] Evaluation of the Contact Area in Total Knee Arthroplasty Designed for Deep Knee Flexion
    Triwardono, Joko
    Supriadi, Sugeng
    Whulanza, Yudan
    Saragih, Agung Shamsuddin
    Novalianita, Deva Ariana
    Utomo, Muhammad Satrio
    Kartika, Ika
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2021, 12 (06) : 1312 - 1322
  • [2] Development of a Passive Knee Motion Simulator to Evaluate Deep Knee Flexion of Total Knee Prosthesis
    Takano, Y.
    Ueno, M.
    Kiguchi, K.
    Itou, J.
    Mawatari, M.
    Hotokebuchi, T.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 540 - 543
  • [3] Total Knee Arthroplasty in the Valgus Knee
    Mannino, Angelo
    Weinberg, Maxwell E.
    Scuderi, Giles R.
    JOURNAL OF KNEE SURGERY, 2024, 37 (02) : 86 - 91
  • [4] Total knee arthroplasty in the valgus knee
    Roberto Rossi
    Federica Rosso
    Umberto Cottino
    Federico Dettoni
    Davide Edoardo Bonasia
    Matteo Bruzzone
    International Orthopaedics, 2014, 38 : 273 - 283
  • [5] Total knee arthroplasty in the valgus knee
    Rossi, Roberto
    Rosso, Federica
    Cottino, Umberto
    Dettoni, Federico
    Bonasia, Davide Edoardo
    Bruzzone, Matteo
    INTERNATIONAL ORTHOPAEDICS, 2014, 38 (02) : 273 - 283
  • [6] VALGUS KNEE BRACING FOR MEDIAL KNEE OSTEOARTHRITIS AND VARUS MALALIGNMENT: A PILOT STUDY
    Hall, M.
    Starkey, S.
    Hinman, R. S.
    Diamond, L. E.
    Lenton, G. K.
    Knox, G.
    Pizzolato, C.
    Paterson, K. L.
    Saxby, D. J.
    OSTEOARTHRITIS AND CARTILAGE, 2021, 29 : S173 - S174
  • [7] Differential Effect of Total Knee Arthroplasty on Valgus and Varus Knee Biomechanics During Gait
    Rodriguez, Jose A.
    Bas, Marcel A.
    Orishimo, Karl F.
    Robinson, Jonathan
    Nicholas, Stephen J.
    JOURNAL OF ARTHROPLASTY, 2016, 31 (09): : S248 - S253
  • [8] Effectiveness of Kinematic Alignment-Total Knee Arthroplasty in Treating Preoperative Varus and Valgus Deformities in Patients With Knee Osteoarthritis
    Davis, Kyle R.
    Soti, Varun
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (01)
  • [9] SEVERE VARUS AND VALGUS DEFORMITIES TREATED BY TOTAL KNEE ARTHROPLASTY
    KARACHALIOS, T
    SARANGI, PP
    NEWMAN, JH
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (06): : 938 - 942
  • [10] Varus/valgus alignment of the tibial component in total knee arthroplasty
    Jeffcote, B
    Shakespeare, D
    KNEE, 2003, 10 (03): : 243 - 247