Thermal Simulation and Analysis of Dry-Type Air-Core Reactors Based on Multi-Physics Coupling

被引:7
|
作者
Wu, Jie [1 ,2 ]
Chang, Zhengwei [1 ,2 ]
Zhang, Huajie [1 ,2 ]
Zhang, Man [3 ]
Peng, Yumin [3 ]
Liao, Jun [1 ]
Huang, Qi [2 ,3 ]
机构
[1] State Grid Sichuan Elect Power Co, Elect Power Res Inst, Chengdu 610041, Peoples R China
[2] Power Syst Wide Area Measurement & Control Sichuan, Chengdu 611731, Peoples R China
[3] Univ Elect Sci & Technol China, Sch Mech & Elect Engn, Chengdu 611731, Peoples R China
关键词
dry-type air-core reactor; multi-physics coupling; thermal performance; electromagnetic; thermal-fluid; finite element method;
D O I
10.3390/en16217456
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A reactor is an important piece of equipment used for reactive power compensation in power system and has a significant impact on the safe operation of power system. Thermal behavior is one of the main causes of reactor failures. For an accurate analysis of the thermal behavior of reactors, electromagnetic-thermal-fluid multi-physics coupling modeling is chosen. However, there is a huge difference in size between the overall structure of the reactor and its insulating material, which makes it difficult to perform mesh generation, resulting in dense mesh and significantly increased solution degrees of freedom, thus making the solution of the reactor's multi-physics field model very time-consuming. To address this, this paper proposes a simplified processing method to accelerate the solution calculation of the reactor's multi-physics model. This method calculates the equivalent turns of each encapsulate with parallel coils in the reactor, simplifying the encapsulate into a single-layer coil, thereby greatly reducing the division and solution degrees of freedom of the multi-physics model, and thus accelerating the simulation calculation. Taking a BKDCKL-20000/35 dry-type air-core shunt reactor as an example, the outer diameter of the coil is nearly 12,000 times bigger than the coil insulation, which is a huge size difference. Both refined models and simplified models are established. Compared to the simulation results of the detailed model, the simplified model demonstrates good accuracy; the maximum relative error of temperature is just 2.19%. Meanwhile, the computational time of the simplified model is reduced by 35.7%, which shows promising effectiveness and significant potential for applying the optimization design and operation prediction of dry-type air-core shunt reactors for enhanced thermal performance.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Numerical simulation and detection of dry-type air-core reactor temperature field based on laminar-turbulent model
    Li, Chuan
    Wang, Han
    Luo, Chuan
    Zhang, Dacheng
    Wan, Xiaorong
    Zhao, Zhengang
    Li, Yingna
    AIP ADVANCES, 2021, 11 (03)
  • [32] Calculation of temperature field of dry-type air-core damping reactor based on coupled method
    Liu, Zhigang
    Wang, Jianhua
    Geng, Yingsan
    Wu, Anbo
    Shi, Canghui
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2003, 37 (06): : 622 - 625
  • [33] Transient Overvoltage Calculation of Dry-type Air-core Reactor with Complex Topology
    Zhu, Dengfeng
    Jin, Liang
    TWENTIETH BIENNIAL IEEE CONFERENCE ON ELECTROMAGNETIC FIELD COMPUTATION (IEEE CEFC 2022), 2022,
  • [34] Fault Early Warning and Location of Dry-Type Air-Core Reactor Based on Neural Networks
    He, Lin
    2021 13TH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA 2021), 2021, : 813 - 818
  • [35] Air-core dry-type shunt reactor protection based on an alternative current alpha plane
    Silva de Almeida, Maria Leonor
    Peres, Larissa Marques
    dos Santos, Guilherme Gomes
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2021, 15 (01) : 34 - 44
  • [36] Fault Early Warning and Location of Dry-Type Air-Core Reactor Based on Temperature Field
    He, Lin
    2021 13TH INTERNATIONAL CONFERENCE ON MEASURING TECHNOLOGY AND MECHATRONICS AUTOMATION (ICMTMA 2021), 2021, : 50 - 54
  • [37] Fault Diagnosis of Dry-type Air-Core Reactor Based on Temperature Field with Multi-Component Normal Distributions
    He, Lin
    Huang, Zhengyi
    PROCEEDINGS OF THE 32ND 2020 CHINESE CONTROL AND DECISION CONFERENCE (CCDC 2020), 2020, : 4710 - 4714
  • [38] Lightning faults of DC dry-type air-core reactor in HVDC substation
    Lei, Xiao
    Xu, Jingyao
    Feng, Bo
    Chen, Shengqing
    ENERGY REPORTS, 2022, 8 : 1378 - 1385
  • [39] 420 kV shunt reactors for reactive power compensation explaining the trends favoring air-core dry-type technology
    Gaun, Alexander
    Grisenti, Alex
    Frohlich, Bernhard
    Niederauer, Christian
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2023, 140 (01): : 144 - 152
  • [40] Investigation of Comparison on Optimal Structure of Five-Loop Simplified Scaling Model for Dry-Type Air-Core Reactors
    Dai L.
    Zou L.
    Sun Y.
    Liu Q.
    Zhang L.
    Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (04): : 1088 - 1103