Characteristics of detection accuracy of the patient setup using InBore optical patient positioning system

被引:1
|
作者
Oku, Yoshifumi [1 ]
Toyota, Masahiko [1 ]
Saigo, Yasumasa [1 ]
机构
[1] Kagoshima Univ Hosp, Div Radiol, Dept Clin Technol, 8-35-1 Sakuragaoka, Kagoshima, Kagoshima 8908520, Japan
关键词
Surface-guided radiation therapy; InBore system; Patient setup; Detection accuracy; SURFACE IMAGING-SYSTEM; LOCALIZATION;
D O I
10.1007/s12194-023-00741-2
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study aimed to evaluate the detection accuracy of the AlignRT-InBore system in surface-guided radiation therapy using a phantom and to determine the feasibility of the system by conducting a comparative analysis with cone-beam computed tomography (CBCT) registration. The AlignRT-InBore system integrated with the ETHOS Therapy was used. A phantom and a QUASAR phantom were employed to examine the specific areas of interest relevant to clinical cases. The evaluation involved monitoring translations for approximately 30 min and assessing the position detection accuracy for static and moving objects. Fifty clinical cases were used to evaluate the position detection accuracy and its relationship with the localization accuracy of CBCT before treatment. The detection accuracy of static and moving objects was within 1.0 mm using the phantom. However, the longitudinal direction tended to be larger than the other directions. Regarding the accuracy of localization in clinical cases, a strong and statistically significant (p < 0.01) correlation was observed in each direction. A detection accuracy within 1.0 mm is possible for static and moving objects. The detection accuracy of the patient setup using the InBore optical patient positioning system was extremely high, and the patient could be detected with high precision, suggesting its usefulness.
引用
收藏
页码:532 / 542
页数:11
相关论文
共 50 条
  • [1] Characteristics of detection accuracy of the patient setup using InBore optical patient positioning system
    Yoshifumi Oku
    Masahiko Toyota
    Yasumasa Saigo
    Radiological Physics and Technology, 2023, 16 : 532 - 542
  • [2] Evaluating the setup accuracy of patient positioning and transfer system in radiotherapy
    Cheng, K. F.
    Mui, W. L.
    Yu, S. K.
    Cheung, K. Y.
    Hui, G.
    Yang, B. K.
    Chiu, G.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S135 - S135
  • [3] Accuracy for patient setup positioning with CatalystT HD for deformed cases
    Kadman, B.
    Takemura, A.
    Ito, T.
    Okada, N.
    Kojima, H.
    Ueda, S.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1499 - S1499
  • [4] Automatic Detection of Patient Identification and Patient Positioning Errors Using 3D Setup Images
    Jani, S.
    O'Connell, D.
    Chow, P.
    Agazaryan, N.
    Low, D.
    Lamb, J.
    MEDICAL PHYSICS, 2014, 41 (06) : 96 - 96
  • [5] A study on the positioning accuracy of patient positioning based on Optical Positioning System for nasopharyngeal carcinoma: Compared with conventional method
    Zhang, Jie
    Ge, Yun
    Chen, Ying
    Chen, Xiangning
    PROCEEDINGS OF 2013 IEEE INTERNATIONAL CONFERENCE ON MEDICAL IMAGING PHYSICS AND ENGINEERING (ICMIPE), 2013, : 11 - 13
  • [6] Positioning accuracy using an image-guided patient localization system
    Yan, H
    Yin, F
    Kim, J
    MEDICAL PHYSICS, 2002, 29 (06) : 1241 - 1241
  • [7] The impact of patient positioning lasers on setup accuracy for MR-Linac radiotherapy
    Hogan, L.
    Jameson, M.
    Crawford, D.
    Biggerstaff, K.
    Picton, M.
    Tran, C.
    McKenzie, L.
    Liang, T.
    Carr, M.
    DeLeon, J.
    Tan, H.
    Batumalai, V.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S2045 - S2046
  • [8] Accuracy evaluation of the Optical Surface Monitoring System on EDGE linear accelerator for patient positioning
    Palumbo, V.
    Mancosu, P.
    Stravato, A.
    Ascolese, A. M.
    Fogliata, A.
    Cozzi, L.
    Gaudino, A.
    Lobefalo, F.
    Navarria, P.
    Reggiori, G.
    Scorsetti, M.
    Tomatis, S.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S915 - S916
  • [9] Position Accuracy of Using Patient Positioning and Transfer System With Head and Neck Immobilization
    Cheng, K. F.
    Fok, P. H.
    Chiu, G.
    Mui, W. L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E647 - E647
  • [10] An Optical Guidance System for Patient Setup in Breast Radiotherapy
    Schmitt, J.
    Hoffmann, K.
    Malhotra, H.
    Bakhtiari, M.
    Nazareth, D.
    MEDICAL PHYSICS, 2008, 35 (06)