Diagnostic validation of smart wearable device embedded with single-lead electrocardiogram for arrhythmia detection

被引:3
|
作者
Niu, Yonghong [1 ]
Wang, Hao [2 ]
Wang, Hong [3 ,4 ]
Zhang, Hui [3 ]
Jin, Zhigeng [3 ]
Guo, Yutao [3 ]
机构
[1] Tsinghua Univ, Affiliated Hosp 1, Dept Cardiol, Beijing, Peoples R China
[2] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 2, Natl Clin Res Ctr Geriatr Dis, Dept Cardiol, Beijing, Peoples R China
[3] Chinese Peoples Liberat Army Gen Hosp, Med Ctr 6, Dept Pulm Vessel & Thrombot Dis, 5 Fucheng Rd, Beijing 100048, Peoples R China
[4] Peoples Liberat Army Gen Hosp, Grad Sch, Beijing, Peoples R China
来源
DIGITAL HEALTH | 2023年 / 9卷
关键词
Atrial fibrillation; atrial premature beats; single-lead ECG; ventricular premature beats; wearables; ATRIAL-FIBRILLATION; MANAGEMENT;
D O I
10.1177/20552076231198682
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
ObjectiveTo validate a single-lead electrocardiogram algorithm for identifying atrial fibrillation, atrial premature beats, ventricular premature beats, and sinus rhythm.MethodsA total of 656 subjects aged 19 to 94 years were enrolled. Participants were simultaneously tested with a wristwatch (Huawei Watch GT2 Pro, Huawei Technologies Co., Ltd, Shenzhen, China) and a 12-lead electrocardiogram for 3 minutes. A total of 1926 electrocardiogram signals from 628 subjects (282 men and 346 women) aged 19 to 94 years (median 64 years) were analyzed using an algorithm.ResultsThe numbers of subjects with atrial fibrillation, atrial premature beats, ventricular premature beats, and sinus rhythm were 129, 141, 107, and 251, respectively, and together they had a total of 1926 electrocardiogram signals. For the three-class classification system, the recall, precision, and F1 score were 97.6%, 96.5%, 97.0% for sinus rhythm; 96.7%, 96.9%, 96.8% for atrial fibrillation; and 92.8%, 94.2%, 93.5% for ectopic beats, respectively. The macro-F1 score of the three-class classification system was 95.8%. For the four-class classification system, the recall, precision, and F1 score were 97.6%, 96.5%, 97.0% for sinus rhythm; 96.7%, 96.9%, 96.8% for atrial fibrillation; 90.5%, 89.4%, 89.9% for atrial premature beats; and 86.1%, 89.6%, 87.8% for ventricular premature beats, respectively. The macro-F1 score of the four-class classification system was 92.9%.ConclusionsThe single-lead electrocardiogram algorithm embedded into smart wearables demonstrated good performance in detecting atrial fibrillation, atrial/ventricular premature beats, and sinus rhythm, and thus would facilitate atrial fibrillation screening and management.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Accuracy of a smartwatch based single-lead electrocardiogram device in detection of atrial fibrillation
    Rajakariar, Kevin
    Koshy, Anoop N.
    Sajeev, Jithin K.
    Nair, Sachin
    Roberts, Louise
    Teh, Andrew W.
    HEART, 2020, 106 (09) : 665 - 670
  • [2] A Wearable Long-Term Single-Lead ECG Processor for Early Detection of Cardiac Arrhythmia
    Abubakar, Syed Muhammad
    Saadeh, Wala
    Bin Altaf, Muhammad Awais
    PROCEEDINGS OF THE 2018 DESIGN, AUTOMATION & TEST IN EUROPE CONFERENCE & EXHIBITION (DATE), 2018, : 961 - 966
  • [3] Multiple electrocardiogram generator with single-lead electrocardiogram
    Seo, Hyo-Chang
    Yoon, Gi-Won
    Joo, Segyeong
    Nam, Gi-Byoung
    COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 2022, 221
  • [4] Modified positioning of a smartphone based single-lead electrocardiogram device improves detection of atrial flutter
    Rajakariar, Kevin
    Koshy, Anoop N.
    Sajeev, Jithin K.
    Nair, Sachin
    Roberts, Louise
    Teh, Andrew W.
    JOURNAL OF ELECTROCARDIOLOGY, 2018, 51 (05) : 884 - 888
  • [5] Development and Validation of Embedded Device for Electrocardiogram Arrhythmia Empowered with Transfer Learning
    Asif, Rizwana Naz
    Abbas, Sagheer
    Khan, Muhammad Adnan
    Atta-ur-Rahman, Kiran
    Sultan, Kiran
    Mahmud, Maqsood
    Mosavi, Amir
    COMPUTATIONAL INTELLIGENCE AND NEUROSCIENCE, 2022, 2022
  • [6] Portable single-lead electrocardiogram device is accurate for QTc evaluation in hospitalized patients
    Monica Marin, Maria
    Alberto Garcia, Angel
    Munoz, Oscar Mauricio, V
    Cesar Castellanos, Julio
    Caceres, Edward
    Santacruz, David
    HEART RHYTHM O2, 2021, 2 (04): : 382 - 387
  • [7] Accuracy of a smartwatch based single-lead electrocardiogram device in screening for atrial fibrillation
    Rajakariar, K.
    Koshy, A. N.
    Sajeev, J. K.
    Nair, S.
    Roberts, L.
    Teh, A. W.
    EUROPEAN HEART JOURNAL, 2019, 40 : 185 - 185
  • [8] Automated processing of the single-lead electrocardiogram for the detection of obstructive sleep apnoea
    de Chazal, P
    Heneghan, C
    Sheridan, E
    Reilly, R
    Nolan, P
    O'Malley, M
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2003, 50 (06) : 686 - 696
  • [9] An Evolutionary-Neural Mechanism for Arrhythmia Classification With Optimum Features Using Single-Lead Electrocardiogram
    Nasim, Amnah
    Nchekwube, David C.
    Munir, Farzeen
    Kim, Yoon Sang
    IEEE ACCESS, 2022, 10 : 99050 - 99065
  • [10] Design and Packaging of a Custom Single-lead Electrocardiogram (ECG) Sensor Embedded with Wireless Transmission
    Rahman, Mahfuzur
    Hewitt, Robert
    Morshed, Bashir I.
    2023 IEEE 16TH DALLAS CIRCUITS AND SYSTEMS CONFERENCE, DCAS, 2023,