Flexible capacitive pressure sensor based on interdigital electrodes with porous microneedle arrays for physiological signal monitoring

被引:4
|
作者
Xu, Jiahui [1 ]
Wang, Minghao [1 ,2 ]
Jin, Minyi [1 ]
Shang, Siyan [1 ]
Ni, Chuner [1 ]
Hu, Yili [3 ]
Sun, Xun [4 ]
Xu, Jun [4 ]
Ji, Bowen [5 ]
Li, Le [6 ]
Cheng, Yuhua [1 ,2 ]
Wang, Gaofeng [1 ]
机构
[1] Hangzhou Dianzi Univ, MOE Engn Res Ctr Smart Microsensors & Microsyst, Sch Elect & Informat, Hangzhou 310018, Peoples R China
[2] Hangzhou Dianzi Univ, Wenzhou Inst, Wenzhou 310018, Peoples R China
[3] Zhejiang Normal Univ, Coll Engn, Inst Precis Machinery & Smart Struct, Key Lab Intelligent Operat & Maintenance Technol &, Jinhua 321004, Zhejiang, Peoples R China
[4] Inst Guizhou Aerosp Measuring & Testing Technol, Guiyang 550009, Peoples R China
[5] Northwestern Polytech Univ, Unmanned Syst Res Inst, Xian 710072, Peoples R China
[6] Northwestern Polytech Univ Shenzhen, Res & Dev Inst, Shenzhen 518057, Peoples R China
基金
中国国家自然科学基金;
关键词
Capacitive pressure sensor; Microneedle array; Porous PDMS; Interdigital electrode;
D O I
10.1063/10.0022174
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Flexible pressure sensors have many potential applications in the monitoring of physiological signals because of their good biocompatibility and wearability. However, their relatively low sensitivity, linearity, and stability have hindered their large-scale commercial application. Herein, a flexible capacitive pressure sensor based on an interdigital electrode structure with two porous microneedle arrays (MNAs) is proposed. The porous substrate that constitutes the MNA is a mixed product of polydimethylsiloxane and NaHCO3. Due to its porous and interdigital structure, the maximum sensitivity (0.07 kPa(-1)) of a porous MNA-based pressure sensor was found to be seven times higher than that of an imporous MNA pressure sensor, and it was much greater than that of a flat pressure sensor without a porous MNA structure. Finite-element analysis showed that the interdigital MNA structure can greatly increase the strain and improve the sensitivity of the sensor. In addition, the porous MNA-based pressure sensor was found to have good stability over 1500 loading cycles as a result of its bilayer parylene-enhanced conductive electrode structure. Most importantly, it was found that the sensor could accurately monitor the motion of a finger, wrist joint, arm, face, abdomen, eye, and Adam's apple. Furthermore, preliminary semantic recognition was achieved by monitoring the movement of the Adam's apple. Finally, multiple pressure sensors were integrated into a 3 x 3 array to detect a spatial pressure distribution. Compared to the sensors reported in previous works, the interdigital electrode structure presented in this work improves sensitivity and stability by modifying the electrode layer rather than the dielectric layer.
引用
收藏
页数:14
相关论文
共 50 条
  • [11] A Sensitive and Flexible Capacitive Pressure Sensor Based on a Porous Hollow Hemisphere Dielectric Layer
    Cui, Haoao
    Liu, Yijian
    Tang, Ruili
    Ren, Jie
    Yao, Liang
    Cai, Yuhao
    Chen, Da
    MICROMACHINES, 2023, 14 (03)
  • [12] Capacitive flexible pressure sensor based on porous GR/PDMS composite dielectric layer
    Chen, Tong
    Wang, Ruirong
    Li, Xiaohong
    AIP ADVANCES, 2024, 14 (05)
  • [13] A Novel Printed Fabric Based Porous Capacitive Pressure Sensor For Flexible Electronic Applications
    Masihi, S.
    Panahi, M.
    Maddipatla, D.
    Bose, A. K.
    Zhang, X.
    Hanson, A. J.
    Palaniappan, V.
    Narakathu, B. B.
    Bazuin, B. J.
    Atashbar, M. Z.
    2019 IEEE SENSORS, 2019,
  • [14] Flexible, Tunable, and Ultrasensitive Capacitive Pressure Sensor with Microconformal Graphene Electrodes
    Yang, Jun
    Luo, Shi
    Zhou, Xi
    Li, Jialu
    Fu, Jianting
    Yang, Weidong
    Wei, Dapeng
    ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (16) : 14997 - 15006
  • [15] Flexible and Wearable Capacitive Pressure Sensor for Monitoring Heart Parameters
    Singh, Lakhvir
    Bhattacharjee, Mitradip
    IEEE Journal on Flexible Electronics, 2023, 2 (02): : 77 - 83
  • [16] A Flexible Capacitive Pressure Sensor for Wearable Respiration Monitoring System
    Park, Seong Won
    Das, Partha Sarati
    Chhetry, Ashok
    Park, Jae Yeong
    IEEE SENSORS JOURNAL, 2017, 17 (20) : 6558 - 6564
  • [17] Flexible capacitive pressure sensor based on multi-walled carbon nanotubes microstructure electrodes
    Chen, Yucheng
    Zhang, Peng
    Li, Yuxia
    Zhang, Kun
    Su, Jinpeng
    Huang, Liangsong
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2021, 54 (15)
  • [18] Porous fiber paper and 3D patterned electrodes composed high-sensitivity flexible piezoresistive sensor for physiological signal monitoring
    HOU XiaoJuan
    ZHONG JiXin
    HE Jian
    YANG ChangJun
    YU JunBin
    MEI LinYu
    MU JiLiang
    GENG WenPing
    CHOU XiuJian
    ScienceChina(TechnologicalSciences), 2022, 65 (05) : 1169 - 1178
  • [19] Porous fiber paper and 3D patterned electrodes composed high-sensitivity flexible piezoresistive sensor for physiological signal monitoring
    HOU XiaoJuan
    ZHONG JiXin
    HE Jian
    YANG ChangJun
    YU JunBin
    MEI LinYu
    MU JiLiang
    GENG WenPing
    CHOU XiuJian
    Science China Technological Sciences, 2022, (05) : 1169 - 1178
  • [20] Porous fiber paper and 3D patterned electrodes composed high-sensitivity flexible piezoresistive sensor for physiological signal monitoring
    Hou, XiaoJuan
    Zhong, JiXin
    He, Jian
    Yang, ChangJun
    Yu, JunBin
    Mei, LinYu
    Mu, JiLiang
    Geng, WenPing
    Chou, XiuJian
    SCIENCE CHINA-TECHNOLOGICAL SCIENCES, 2022, 65 (05) : 1169 - 1178