Real-Time Temperature Correction of Medical Range Fiber Bragg Gratings Dosimeters

被引:2
|
作者
Lebel-Cormier, Marie-Anne [1 ,2 ,3 ,4 ]
Boilard, Tommy [1 ,5 ]
Beaulieu, Luc [1 ,2 ,3 ,4 ]
Bernier, Martin [1 ,5 ]
机构
[1] Univ Laval, Dept Phys Genie Phys & Opt, Quebec City, PQ G1V 0A6, Canada
[2] Univ Laval, Ctr Rech Canc, Quebec City, PQ G1R 3S3, Canada
[3] CHU Quebec Univ Laval, Quebec City, PQ G1R 2J6, Canada
[4] CRCHU Quebec, Quebec City, PQ G1R 2J6, Canada
[5] Univ Laval, Ctr Opt Photon & Laser COPL, Quebec City, PQ G1V 0A6, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
fiber dosimetry; FBG temperature correction; radiotherapy multi-points dosimetry; STRAIN; SENSORS;
D O I
10.3390/s23020886
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The interest in fiber Bragg gratings dosimeters for radiotherapy dosimetry lies in their (i) submillimeter size, (ii) multi-points dose measurements, and (iii) customizable spatial resolution. However, since the radiation measurement relies on the thermal expansion of the surrounding polymer coating, such sensors are strongly temperature dependent, which needs to be accounted for; otherwise, the errors on measurements can be higher than the measurements themselves. In this paper, we test and compare four techniques for temperature compensation: two types of dual grating techniques using different coatings, a pre-irradiation and post-irradiation temperature drift technique, which is used for calorimetry, and finally, we developed a real-time interpolated temperature gradient for the multi-points dosimetry technique. We show that, over these four tested techniques, the last one outperforms the others and allows for real-time temperature correction when an array of 13 fiber Bragg gratings spatially extending over the irradiation zone is used. For a 20 Gy irradiation, this technique reduces the measurement errors from 200% to about 10%, making it suitable for a radiotherapy dose range. Temperature correction for medical low-dose range dosimetry is a first in our field and is essential for clinical FBG dosimetry applications.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Temperature-Insensitive Real-Time Inclinometer Based on an Etched Fiber Bragg Grating
    Zhang, Qiang
    Zhu, Tao
    Yin, Fengyang
    Chiang, Kin Seng
    IEEE PHOTONICS TECHNOLOGY LETTERS, 2014, 26 (10) : 1049 - 1052
  • [22] Real-time temperature measurement with fiber Bragg sensors in lithium batteries for safety usage
    Yang, Gang
    Leitao, Catia
    Li, Yuhong
    Pinto, Joao
    Jiang, Xuefan
    MEASUREMENT, 2013, 46 (09) : 3166 - 3172
  • [23] Medical Range Radiation Dosimeter Based on Polymer-Embedded Fiber Bragg Gratings
    Lebel-Cormier, Marie-Anne
    Boilard, Tommy
    Bernier, Martin
    Beaulieu, Luc
    SENSORS, 2021, 21 (23)
  • [24] Real-time, distributed measurement of detonation velocities inside high explosives with the help of Chirped Fiber Bragg Gratings
    Magne, Sylvain
    Lefrancois, Alexandre
    Luc, Jerome
    Laffont, Guillaume
    Ferdinand, Pierre
    FIFTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2013, 8794
  • [25] Real-time measurement of reflection wavelength of fiber Bragg gratings with tunable wavelength-swept light source
    Yamaguchi, Tatsuya
    Shinoda, Yukitaka
    IEEJ Transactions on Fundamentals and Materials, 2015, 135 (12) : 756 - 761
  • [26] Temperature compensation package for fiber Bragg gratings
    Huang, YL
    Li, J
    Kai, GY
    Yuan, SH
    Dong, XY
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2003, 39 (01) : 70 - 72
  • [27] High temperature, stable fiber Bragg gratings
    Winz, M
    Stump, K
    Plant, TK
    OFS 2002: 15TH OPTICAL FIBER SENSORS CONFERENCE TECHNICAL DIGEST, 2002, : 195 - 198
  • [28] Correction of systematic errors in the fabrication of fiber Bragg gratings
    Buryak, AV
    Stepanov, DY
    OPTICS LETTERS, 2002, 27 (13) : 1099 - 1101
  • [29] Real-time measurement of harmonic frequency with fiber Bragg grating
    Chen, Zhe-Min
    Chen, Jun
    Wu, Xiao-Dong
    Zhu, Xiao-Ping
    Zhongguo Jiguang/Chinese Journal of Lasers, 2005, 32 (09): : 1230 - 1234
  • [30] Real-time optical spectrum analyser based on chirped fibre Bragg gratings
    Berger, NK
    Levit, B
    Bekker, A
    Fischer, B
    ELECTRONICS LETTERS, 2000, 36 (14) : 1189 - 1191