Laboratory evaluation of high-temperature resistant lysine-based polymer Gel systems for leakage control

被引:5
|
作者
Song, Tao [1 ,2 ]
Tian, Xuyang [1 ]
Bai, Baojun [1 ]
Eriyagama, Yugandhara [3 ]
Ahdaya, Mohamed [1 ]
Alotibi, Adel [1 ]
Schuman, Thomas [3 ]
机构
[1] Missouri Univ Sci & Technol, Dept Geosci & Geol & Petr Engn, Rolla, MO 65409 USA
[2] Petrochina Res Inst Petr Explorat & Dev, Beijing 100083, Peoples R China
[3] Missouri Univ Sci & Technol, Dept Chem, Rolla, MO 65409 USA
来源
关键词
Green crosslinker; Water management; Polymer gels; Leakage control; STABILITY; SALINITY; GAS;
D O I
10.1016/j.geoen.2024.212685
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In-situ crosslinking gel known for its cost-effectiveness, has been employed for decades to plug high-permeability features in subsurface environments. However, some commonly used crosslinkers are being phased out due to the increasingly rigorous environmental regulations. As a newly discovered environmentally friendly crosslinker, lysine can crosslink the partially hydrolyzed polyacrylamide through transamidation reaction. The present work aimed to study the effect of polymer composition and concentration on the gelation behavior of lysine and high molecular weight acrylamide-based polymers. Several commercial high molecular weight polymers with different contents of 2-Acrylamido-2-methyl-1-propane sulfonic acid (AMPS) including AN -105/125, SAV-55/ 37/28, and SAV-10 were deployed in this work. High-temperature/pressure-resistant glass tubes were used to study the crosslinking behavior. The plugging efficiency test used a high permeability sandstone core (1600 mD). Besides, the effect of salinity and pH on the crosslinking behavior, gel strength, and long-term thermal stability was also studied. Results showed that increasing the AMPS content could prolong the gelation time, but the polymer and lysine mixture failed to form gels when the AMPS content was excessively high. Additionally, increasing the AMPS content negatively affects the gel strength but positively impacts long-term thermal stability. Polymer gel with a relatively high content of AMPS could be stable in 0.5 % CaCl2 solution at 130 degrees C for over 200 days. The polymer/lysine gel system can efficiently plug the high permeability matrix, and the plugging efficiency is higher than 99 %. The polymer/lysine gel system is a promising green leakage control system in treating the high conductivity features in geothermal and oil reservoirs.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Evaluation of Electrolyte Additives for High-Temperature Polymer Electrolyte Fuel Cells
    Mack, Florian
    Galbiati, Samuele
    Gogel, Viktor
    Joerissen, Ludwig
    Zeis, Roswitha
    CHEMELECTROCHEM, 2016, 3 (05): : 770 - 773
  • [42] Experimental study of polyacrylamide polymer gel for profile controlling in high-temperature offshore reservoirs
    Han, Xiaodong
    Zhong, Liguo
    Liu, Yigang
    Wang, Qiuxia
    Wang, Cheng
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2024, 46 (01) : 11133 - 11147
  • [43] SEMI-2-INTERPENETRATING POLYMER NETWORKS OF HIGH-TEMPERATURE SYSTEMS
    HANKY, AO
    STCLAIR, TL
    SAMPE JOURNAL, 1985, 21 (04) : 40 - 45
  • [44] A NOVEL TEMPERATURE-RESISTANT WATER-BASED POLYMER GEL SYSTEM AND EVALUATION OF WELLBORE GAS CHANNELING PERFORMANCE
    Li, Shuanggui
    Gao, Wei
    Zhang, Jun
    FRESENIUS ENVIRONMENTAL BULLETIN, 2021, 30 (08): : 10113 - 10119
  • [45] Development and evaluation of foam-based conformance control for a high-salinity and high-temperature carbonate
    Alhasan B. Fuseni
    Abdulkareem M. AlSofi
    Ali H. AlJulaih
    Abdulrahman A. AlAseeri
    Journal of Petroleum Exploration and Production Technology, 2018, 8 : 1341 - 1348
  • [46] An Optimization Study of Polyacrylamide-Polyethylenimine-Based Polymer Gel for High Temperature Reservoir Conformance Control
    Amir, Zulhelmi
    Saaid, Ismail Mohd
    Jan, Badrul Mohamed
    INTERNATIONAL JOURNAL OF POLYMER SCIENCE, 2018, 2018
  • [47] Development and evaluation of foam-based conformance control for a high-salinity and high-temperature carbonate
    Fuseni, Alhasan B.
    AlSofi, Abdulkareem M.
    AlJulaih, Ali H.
    AlAseeri, Abdulrahman A.
    JOURNAL OF PETROLEUM EXPLORATION AND PRODUCTION TECHNOLOGY, 2018, 8 (04) : 1341 - 1348
  • [48] A comparative evaluation of high-temperature membrane systems for catalytic processing
    Gobina, E
    Hou, KH
    Hughes, R
    CHEMICAL ENGINEERING COMMUNICATIONS, 1998, 166 : 157 - 181
  • [49] Development and Performance Evaluation of a High-Temperature Profile Control System
    Wang, Chunsheng
    Zhang, Lei
    Ju, Guoshuai
    Sun, Qiji
    ACS OMEGA, 2020, 5 (28): : 17828 - 17838
  • [50] Wireless SAW based high-temperature measurement systems
    Fachberger, R.
    Bruckner, G.
    Hauser, R.
    Reindl, L.
    PROCEEDINGS OF THE 2006 IEEE INTERNATIONAL FREQUENCY CONTROL SYMPOSIUM AND EXPOSITION, VOLS 1 AND 2, 2006, : 358 - +