Load Frequency Control for Unequal Multi-Area Power System by Generation Control Strategy Using CFO (PR)2 Controller

被引:1
|
作者
Kannepally, Swetha [1 ,3 ]
Vijaya Kumar, Darapureddi [2 ]
Vakula, Venkata Swarna [1 ]
机构
[1] JNTU GV Coll Engn, Dept Elect & Elect Engn, Vizianagaram, Andhra Prades, India
[2] Aditya Inst Technol & Management, Dept Elect & Elect Engn, Tekkali, Andhra Prades, India
[3] JNTU GV Coll Engn, Dept Elect & Elect Engn, Vizianagaram 535003, Andhra Prades, India
关键词
cascade controller; proportional resonant controller; fractional orders; frequency deviation; tie-line power; average and subtraction-based optimizer; automatic generation control and multi-area system; STABILITY ANALYSIS; FEEDBACK-CONTROL; PID CONTROLLER; SEARCH; DESIGN; AGC; ALGORITHM; MODEL;
D O I
10.1080/15325008.2023.2253804
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An interconnected system is raised by integrating different generators in the power system of multiple areas that satisfies varying load demand. Frequency fluctuations occur in the system due to the interconnection of multiple generators. The voltage variations in any area may induce frequency variations in the system. Hence to solve the issue, a cascade fractional order proportional resonant (CFO(PR)2) controller is proposed in this work. The objective of a control model is to reduce the error function; hence the controller is tuned by a highly efficient optimization model named an average and subtraction-based optimizer (ASBO). The proposed controller's results are compared with the existing controllers to check the performance efficacy. The comparative analysis shows that the proposed controller performs better regarding lower errors. Finally, the model is tested under four scenarios by randomly changing the load at a different area.
引用
收藏
页数:19
相关论文
共 50 条
  • [22] Multi-area Load Frequency Control using IP controller tuned by Tabu Search
    Shirvani, Mojtaba
    Abdollahi, Mostafa
    Memaripour, Ahmad
    Behzadipour, Elahe
    [J]. PRZEGLAD ELEKTROTECHNICZNY, 2012, 88 (08): : 244 - 248
  • [23] Optimal Load Frequency Control of Multi-Area Power System Considering Incremental Control Action
    Kunya, A. B.
    Argin, M.
    Kucuksari, S.
    [J]. 2019 IEEE TEXAS POWER AND ENERGY CONFERENCE (TPEC), 2019,
  • [24] Robust Control of Frequency for Multi-Area Power System
    Tabassum, Fariya
    Rana, M. S.
    [J]. 2020 IEEE REGION 10 SYMPOSIUM (TENSYMP) - TECHNOLOGY FOR IMPACTFUL SUSTAINABLE DEVELOPMENT, 2020, : 86 - 89
  • [25] Design and performance analysis of adaptive neuro fuzzy controller for load frequency control of multi-area power system
    Nath, Vivek
    Sambariya, D. K.
    [J]. PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INTELLIGENT SYSTEMS AND CONTROL (ISCO'16), 2016,
  • [26] Fuzzy Based Integral Controller for an Automatic Generation Control in Multi-Area Power System
    Hossain, M. F.
    Islam, M. R.
    Rabbani, M. G.
    Rahman, M. F.
    Takahashi, T.
    [J]. INTERNATIONAL ENERGY JOURNAL, 2008, 9 (04): : 275 - 280
  • [27] Automatic generation control of multi-area interconnected power systems using ANN controller
    [J]. Alzaareer, Khaled (Khaled.alzaareer.1@ens.etsmtl.ca), 1600, International Information and Engineering Technology Association (34):
  • [28] Load Frequency Control of a Multi-Area Power System by Optimum Designing of Frequency-Based PID Controller Using Seeker Optimization Algorithm
    Parvaneh, Hesam
    Dizgah, Shahriar Moradinejad
    Sedighizadeh, Mostafa
    Ardeshir, Soheib Takht
    [J]. 2016 6TH CONFERENCE ON THERMAL POWER PLANTS (CTPP), 2016, : 52 - 57
  • [29] Automatic generation control of multi-area power systems using reduced order controller
    Cherid, A
    Bettayeb, M
    [J]. ELECTRIC MACHINES AND POWER SYSTEMS, 1996, 24 (01): : 1 - 8
  • [30] Tube-based MPC strategy for load frequency control of multi-area interconnected power system with HESS
    An, Zhuoer
    Liu, Xinghua
    Xiao, Gaoxi
    Song, Guangyu
    Wang, Peng
    [J]. JOURNAL OF ENERGY STORAGE, 2024, 99