Assembly precision design for parallel robotic mechanism based on uncertain hybrid tolerance allocation

被引:3
|
作者
Xu, Jinghua [1 ,2 ]
Tao, Mingzhe [1 ,2 ]
Gao, Mingyu [1 ,2 ]
Zhang, Shuyou [1 ,2 ]
Tan, Jianrong [1 ,2 ]
Xu, Jingxuan [3 ]
Wang, Kang [4 ,5 ]
机构
[1] State Key Lab Fluid Power & Mechatron Syst, Hangzhou, Peoples R China
[2] Key Lab Adv Mfg Technol Zhejiang Prov, Hangzhou, Peoples R China
[3] Qingdao Binhai Univ, Affiliated Hosp, Qingdao, Peoples R China
[4] Zhejiang Univ, Inst Design Engn, Hangzhou, Peoples R China
[5] Hong Kong Polytech Univ, Sch Nursing, Kowloon, Hong Kong, Peoples R China
来源
ROBOTIC INTELLIGENCE AND AUTOMATION | 2023年 / 43卷 / 01期
基金
中国国家自然科学基金;
关键词
Assembly precision design; Parallel robotic mechanism; Uncertain hybrid tolerance allocation (UHTA); Hybrid error sensitivity; Robotized positioning precision; OPTIMIZATION; MODEL;
D O I
10.1108/RIA-10-2022-0254
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Purpose The coupling impact of hybrid uncertain errors on the machine precision is complex, as a result of which the designing method with multiple independent error sources under uncertainties remains a challenge. For the purpose of precision improvement, this paper focuses on the robot design and aims to present an assembly precision design method based on uncertain hybrid tolerance allocation (UHTA), to improve the positioning precision of the mechanized robot, as well as realize high precision positioning within the workspace. Design/methodology/approach The fundamentals of the parallel mechanism are introduced first to implement concept design of a 3-R(4S) &3-SS parallel robot. The kinematic modeling of the robot is carried out, and the performance indexes of the robot are calculated via Jacobian matrix, on the basis of which, the 3D spatial overall workspace can be quantified and visualized, under the constraints of limited rod, to avoid the singular position. The error of the robot is described, and a probabilistic error model is hereby developed to classify the hybrid error sensitivity of each independent uncertain error source by Monte Carlo stochastic method. Most innovatively, a methodology called UHTA is proposed to optimize the robot precision, and the tolerance allocation approach is conducted to reduce the overall error amplitude and improve the robotized positioning precision, on the premise of not increasing assembly cost. Findings The proposed approach is validated by digital simulation of medical puncture robot. The experiment highlights the mathematical findings that the horizontal plane positioning error of the parallel robotic mechanism can be effectively reduced after using UHTA, and the average precision can be improved by up to 39.54%. Originality/value The originality lies in UHTA-based precision design method for parallel robots. The proposed method has widely expanding application scenarios in industrial robots, biomedical robots and other assembly automation fields.
引用
收藏
页码:23 / 34
页数:12
相关论文
共 50 条
  • [31] Statistical tolerance allocation design considering form errors based on rigid assembly simulation and deep Q-network
    Ci He
    Shuyou Zhang
    Lemiao Qiu
    Zili Wang
    Yang Wang
    Xiaojian Liu
    The International Journal of Advanced Manufacturing Technology, 2020, 111 : 3029 - 3045
  • [32] Parts Tolerance Allocation based on Assembly Clearance Analysis and Product Functional Parameters
    Zia, Ahmad
    Qiao, Lihong
    HISTORY OF MECHANICAL TECHNOLOGY AND MECHANICAL DESIGN 2012, 2012, 163 : 116 - 120
  • [33] Design of a Double Triangular Parallel Mechanism for Precision Positioning and Large Force Generation
    Shin, Hyunpyo
    Moon, Jun-Hee
    IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2014, 19 (03) : 862 - 871
  • [34] Novel design solution to high precision 3 axes translational parallel mechanism
    Bhutani, Gaurav
    Dwarakanath, T. A.
    MECHANISM AND MACHINE THEORY, 2014, 75 : 118 - 130
  • [35] Design and accuracy evaluation of high-speed and high precision parallel mechanism
    Koseki, Y
    Arai, T
    Sugimoto, K
    Takatuji, T
    Goto, M
    1998 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1-4, 1998, : 1340 - 1345
  • [36] A Compliant Transoral Surgical Robotic System Based on a Parallel Flexible Mechanism
    Xiaoyi Gu
    Changsheng Li
    Xiao Xiao
    Chwee Ming Lim
    Hongliang Ren
    Annals of Biomedical Engineering, 2019, 47 : 1329 - 1344
  • [37] A Compliant Transoral Surgical Robotic System Based on a Parallel Flexible Mechanism
    Gu, Xiaoyi
    Li, Changsheng
    Xiao, Xiao
    Lim, Chwee Ming
    Ren, Hongliang
    ANNALS OF BIOMEDICAL ENGINEERING, 2019, 47 (06) : 1329 - 1344
  • [38] Design and Experimental Characterization of a Flexure Hinge-Based Parallel Four-Bar Mechanism for Precision Guides
    Graeser, P.
    Linss, S.
    Zentner, L.
    Theska, R.
    MICROACTUATORS AND MICROMECHANISMS, MAMM-2016, 2017, 45 : 139 - 152
  • [39] Configuration Design and Size Optimization of a High-Precision Novel Parallel Pointing Mechanism Based on Interference Separation
    Wang, Sen
    Li, Shihua
    Han, Xueyan
    Wei, Jiahao
    Gao, Xueyuan
    Xu, Hongyu
    CHINESE JOURNAL OF MECHANICAL ENGINEERING, 2024, 37 (01)
  • [40] Design and Kinematic Analysis of a Novel Series-Parallel Hybrid Finger for Robotic Hands
    Zaw, Thiha
    Mahalingam, Dasharadhan
    Baiata, Nicholas
    Patankar, Aditya
    Chakraborty, Nilanjan
    JOURNAL OF MECHANISMS AND ROBOTICS-TRANSACTIONS OF THE ASME, 2025, 17 (04):