The alcohol biomarker phosphatidylethanol (PEth) - test performance and experiences from routine analysis and external quality assessment

被引:13
|
作者
Helander, Anders [1 ,2 ,4 ]
Hansson, Therese [3 ]
机构
[1] Karolinska Univ Lab, Dept Clin Chem & Clin Pharmacol, Stockholm, Sweden
[2] Karolinska Inst, Dept Lab Med, Stockholm, Sweden
[3] Skane Univ Hosp, Dept Clin Chem & Clin Pharmacol, Off Med Serv, Div Lab Med, Lund, Sweden
[4] Karolinska Univ Lab Huddinge, Clin Chem, c1-74, Stockholm, Sweden
关键词
Alcohol; alcohol marker; blood; ethanol; phosphatidylethanol; PEth; FATTY-ACID-COMPOSITION; BLOOD PHOSPHATIDYLETHANOL; WHOLE-BLOOD; CONSUMPTION; DRINKING; ETHANOL; SAMPLES; HUMANS; MARKER;
D O I
10.1080/00365513.2023.2253734
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Phosphatidylethanol (PEth) are membrane molecules formed from phosphatidylcholine and ethanol through transphosphatidylation catalyzed by phospholipase D. Measurement of the main PEth form 16:0/18:1 is used as a specific and sensitive alcohol biomarker, since its formation requires ethanol, it accumulates in the blood upon repeated ethanol exposure, and it is only slowly eliminated during abstinence. PEth formation correlates with alcohol intake at the population level, albeit with considerable inter-individual variation as for the half-life during withdrawal. Over the past decade, the use of PEth has increased significantly and the applications have broadened. In Sweden, routine decision limits and the interpretation of test results for PEth were harmonized in 2013, using < 0.05 mu mol/L (similar to 35 mu g/L) as the recommended lower reporting limit and values > 0.30 mu mol/L (similar to 210 mu g/L) to indicate regular high alcohol intake. Routine test results show a large variation with about half being < 0.05 mu mol/L and some even exceeding 10 mu mol/L. In 2013, an external quality assessment (EQA) scheme for PEth 16:0/18:1 measurement in whole blood was also started (Equalis, Uppsala, Sweden), presently involving 56 laboratories from 13 countries. The agreement of PEth results between the laboratories has gradually improved to a CV < 15%. The current clinical and scientific information suggests that PEth values below the lower reporting limit (typically similar to 0.03-0.05 mu mol/L, or similar to 20-35 mu g/L) indicates sobriety or only low or occasional alcohol consumption, while regular high alcohol intake at levels corresponding to harmful drinking is required in most cases to reach PEth values > 0.30 mu mol/L.
引用
收藏
页码:424 / 431
页数:8
相关论文
共 50 条
  • [41] Retrospective Analysis of External Quality Assessment Data of Humoral (Except Feces) Morphology in Guangxi from 2010 to 2022
    Ciying XIAO
    Xiaochun LIU
    Juan TANG
    Hongying ZHAO
    Xiangyang ZHOU
    Shengzhou NONG
    Medicinal Plant, 2023, (02) : 107 - 112
  • [42] Does participation in an External Quality Assessment scheme impact routine laboratory practice? A review of participant data from CMCEQAS over the last 6 years
    Mammen, Joy
    Nair, Sukesh
    Srivastava, Alok
    Singh, Surendar
    Bala, Soumya
    Kavitha, M.
    HAEMOPHILIA, 2016, 22 : 71 - 71
  • [43] FVIII post infusion monitoring survey: Results and analysis of extended half-life (EHL) FVIII/FIX products and laboratory performance for the external quality control assessment programmes of international external quality assessment scheme (IEQAS)
    Williams, Anna
    Kitchen, Dianne
    Reily-Stitt, Chris
    Jennings, Ian
    Kitchen, Steve
    HAEMOPHILIA, 2024, 30 : 82 - 83
  • [44] Quality of MALDI-TOF mass spectra in routine diagnostics: results from an international external quality assessment including 36 laboratories from 12 countries using 47 challenging bacterial strains
    Cuenod, Aline
    Aerni, Martina
    Bagutti, Claudia
    Bayraktar, Banu
    Boz, Efe Serkan
    Carneiro, Cynthia Beisert
    Casanova, Carlo
    Coste, Alix T.
    Damborg, Peter
    van Dam, Dirk W.
    Demirci, Mehmet
    Drevinek, Pavel
    Dubuis, Olivier
    Fernandez, Jose
    Greub, Gilbert
    Hrabak, Jaroslav
    Yigitler, Gulen Hurkal
    Hurych, Jakub
    Jensen, Thoger Gorm
    Jost, Geraldine
    Kampinga, Greetje A.
    Kittl, Sonja
    Lammens, Christine
    Lang, Claudia
    Lienhard, Reto
    Logan, Julie
    Maffioli, Carola
    Marekovic, Ivana
    Marschal, Matthias
    Moran-Gilad, Jacob
    Nolte, Oliver
    Oberle, Michael
    Pedersen, Michael
    Pfluger, Valentin
    Pranghofer, Sigrid
    Reichl, Julia
    Rentenaar, Rob J.
    Riat, Arnaud
    Rodriguez-Sanchez, Belen
    Schilt, Camille
    Schlotterbeck, Ann-Kathrin
    Schrenzel, Jacques
    Troib, Shani
    Willems, Elise
    Wootton, Mandy
    Ziegler, Dominik
    Egli, Adrian
    CLINICAL MICROBIOLOGY AND INFECTION, 2023, 29 (02) : 190 - 199
  • [45] QUALITY OF PERFORMANCE OF ASSAYS FOR MATERNAL SERUM ALPHAFETOPROTEIN IN THE UNITED-KINGDOM - EVIDENCE FROM THE UK EXTERNAL QUALITY ASSESSMENT SCHEME 1980-87
    SETH, J
    HANNING, I
    BACON, RRA
    HUNTER, WM
    ANNALS OF CLINICAL BIOCHEMISTRY, 1988, 25 : 310 - 318
  • [46] Experiences from 4 Years of Organization of an External Quality Assessment for Mycobacterium tuberculosis Whole-Genome Sequencing in the European Union/European Economic Area
    Anthony, R. M.
    Tagliani, E.
    Nikolayevskyy, V
    de Zwaan, R.
    Mulder, A.
    Kamst, M.
    Kodmon, C.
    van der Werf, M. J.
    Cirillo, D.
    van Soolingen, D.
    MICROBIOLOGY SPECTRUM, 2023, 11 (01):
  • [47] Harmonization of PCR-based detection of intestinal pathogens: experiences from the Dutch external quality assessment scheme on molecular diagnosis of protozoa in stool samples
    Schuurs, Theo A.
    Koelewijn, Rob
    Brienen, Eric A. T.
    Kortbeek, Titia
    Mank, Theo G.
    Mulder, Bert
    Stelma, Foekje F.
    van Lieshout, Lisette
    van Hellemond, Jaap J.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2018, 56 (10) : 1722 - 1727
  • [48] Evaluating laboratory performance in Dengue virus detection by using RT-qPCR: Analysis of a Brazilian external quality assessment program results
    Vieira, A.
    Barra, G.
    Lima, S.
    Poloni, J.
    Lopes, R.
    Casali, J.
    Jeronimo, D.
    Vasconcellos, L.
    Biasoli, V.
    CLINICA CHIMICA ACTA, 2024, 558
  • [49] Synthesis, Performance and Emission Quality Assessment of Ecodiesel from Castor Oil in Diesel/Biofuel/Alcohol Triple Blends in a Diesel Engine
    Hurtado, Beatriz
    Posadillo, Alejandro
    Luna, Diego
    Bautista, Felipa M.
    Hidalgo, Jose M.
    Luna, Carlos
    Calero, Juan
    Romero, Antonio A.
    Estevez, Rafael
    CATALYSTS, 2019, 9 (01)
  • [50] The performance of quantitative D-dimer assays in Chinese clinical laboratories by analyzing data from National External quality Assessment Scheme
    Li, Chenbin
    Xu, Chengshan
    Hu, Gaofeng
    Peng, Mingting
    CLINICA CHIMICA ACTA, 2024, 562