Safety and efficacy of ablation index-guided high-power ablation for the treatment of atrial fibrillation

被引:1
|
作者
Zhu, Jing [1 ,2 ]
Lin, Xian-he [1 ]
机构
[1] Anhui Med Univ, Dept Cardiol, Affiliated Hosp 1, Hefei 230000, Anhui, Peoples R China
[2] Anhui Med Univ, Dept Cardiol, Prov Hosp, Hefei 230000, Anhui, Peoples R China
关键词
Atrial fibrillation; High-power; Lesion size index; Radiofrequency ablation; DURATION;
D O I
10.1016/j.heliyon.2023.e15311
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objective: To study the safety and efficacy of high-power ablation for atrial fibrillation (AF) guided by lesion size index (LSI) and impedance cutoff. Method: A total of 223 patients who underwent radiofrequency catheter ablation of atrial fibrillation (including paroxyparal atrial fibrillation and persistent atrial fibrillation) in the Department of Cardiology of Anhui Provincial Hospital from February 2019 to July 2020 were enrolled, and were divided into 123 patients in the high-power ablation group (HPAI) and 100 patients in the conventional power ablation group (CPAI). The HPAI group adopted high-power (40-50 W) ablation by impedance cutoff, and the CPAI group adopted conventional-power (30-35 W) ablation. Patients in both groups were ablated guided by the same LSI. For both groups, we analyzed the pulmonary vein single-circle isolation rate, ablation time, X-ray exposure, impedance drop value, incidence of complications, and recurrence rate within one year after operation. Results: There was no significant difference in the success rate of pulmonary vein single-circle isolation, X-ray perspective time, and X-ray exposure quantity between the HPAI group and the CPAI group (88.60% vs 82.00%, P = 0.161; 8.7 +/- 3.74 min vs 7.82 +/- 3.86 min, P = 0.067; 54.74 +/- 28 min vs 52.78 +/- 39.58 min, P = 0.139); the annular pulmonary vein ablation time and total ablation time were less in the HPAI group (35.74 +/- 7.25 min vs 65.49 +/- 7.34 min, P < 0.01; 55.42 +/- 11.61 min vs 76.9 +/- 6.79 min, P < 0.01); the impedance drop values at 10-15 omega and 15-20 omega were higher in the HPAI group (25.3% vs 19.1%, P < 0.05; 24.1% vs 19.1%, P < 0.05); there was no significant difference in the recurrence rate within one year after operation between the two groups; and no serious complications occurred in the two groups. Conclusion: High-power ablation guided by LSI and impedance cutoff could significantly shorten the AF ablation time and reduce complications.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Efficacy and Safety of High-Power Short-Duration Radiofrequency Catheter Ablation of Atrial Fibrillation
    Park, Je-Wook
    Yang, Song-Yi
    Kim, Min
    Yu, Hee Tae
    Kim, Tae-Hoon
    Uhm, Jae-Sun
    Joung, Boyoung
    Lee, Moon-Hyoung
    Pak, Hui-Nam
    [J]. FRONTIERS IN CARDIOVASCULAR MEDICINE, 2021, 8
  • [32] Can Pre-Ablation Biomarkers Be Used to Predict Arrhythmia Recurrence after Ablation Index-Guided Atrial Fibrillation Ablation?
    Palma, Andreia
    Sousa, Pedro A.
    Saleiro, Carolina
    Adao, Luis
    Barra, Sergio
    Antonio, Natalia
    Primo, Joao
    Lebreiro, Ana
    Fonseca, Paulo
    Elvas, Luis
    Goncalves, Lino
    [J]. ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2024, 121 (04)
  • [33] Efficiency, Safety, and Efficacy of High-Power Short-Duration Radiofrequency Ablation in Patients with Atrial Fibrillation
    Sun, Xuerong
    Lu, Jiang
    Lin, Jinxuan
    Feng, Tianjie
    Suo, Ni
    Zheng, Lihui
    Liu, Zhimin
    Chen, Gang
    Fan, Xiaohan
    Zhang, Shu
    Niu, Guodong
    [J]. CARDIOLOGY RESEARCH AND PRACTICE, 2021, 2021
  • [34] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Shuhei Kobayashi
    Hidehira Fukaya
    Jun Oikawa
    Daiki Saito
    Tetsuro Sato
    Gen Matsuura
    Yuki Arakawa
    Yuki Shirakawa
    Ryo Nishinarita
    Ai Horiguchi
    Naruya Ishizue
    Jun Kishihara
    Shinichi Niwano
    Junya Ako
    [J]. Journal of Interventional Cardiac Electrophysiology, 2021, 62 : 123 - 131
  • [35] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Kobayashi, Shuhei
    Fukaya, Hidehira
    Oikawa, Jun
    Saito, Daiki
    Sato, Tetsuro
    Matsuura, Gen
    Arakawa, Yuki
    Shirakawa, Yuki
    Nishinarita, Ryo
    Horiguchi, Ai
    Ishizue, Naruya
    Kishihara, Jun
    Niwano, Shinichi
    Ako, Junya
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (01) : 123 - 131
  • [36] Incidence and predictors of thermal oesophageal and vagus nerve injuries in Ablation Index-guided high-power-short-duration ablation of atrial fibrillation: a prospective study
    Wolff, Charlotte
    Langenhan, Katharina
    Wolff, Marc
    Efimova, Elena
    Zachaeus, Markus
    Darma, Angeliki
    Dinov, Borislav
    Seewoester, Timm
    Nedios, Sotirios
    Bertagnolli, Livio
    Wolff, Jan
    Paetsch, Ingo
    Jahnke, Cosima
    Bollmann, Andreas
    Hindricks, Gerhard
    Bode, Kerstin
    Halm, Ulrich
    Arya, Arash
    [J]. EUROPACE, 2024, 26 (05):
  • [37] Direct comparison of two 50 W high power short duration approaches-Temperature- versus ablation index-guided radiofrequency ablation for atrial fibrillation
    Guckel, Denise
    Bergau, Leonard
    Braun, Martin
    El Hamriti, Mustapha
    Moersdorf, Maximilian
    Fink, Thomas
    Sciacca, Vanessa
    Khalaph, Moneeb
    Imnadze, Guram
    Sommer, Philipp
    Sohns, Christian
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2022, 33 (12) : 2517 - 2527
  • [38] Can Pre-Ablation Serum Biomarkers be Used to Predict Arrhythmia Recurrence after Ablation Index-Guided Atrial Fibrillation Ablation?
    Chokr, Muhieddine Omar
    [J]. ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2024, 121 (04)
  • [39] Comparison of myocardial injury and inflammation between ablation index-guided and conventional contact force-guided ablation in atrial fibrillation patients
    Yano, Masamichi
    Egami, Yasuyuki
    Kawanami, Shodai
    Sugae, Hiroki
    Ukita, Kohei
    Kawamura, Akito
    Nakamura, Hitoshi
    Yasumoto, Koji
    Tsuda, Masaki
    Okamoto, Naotaka
    Matsunaga-Lee, Yasuharu
    Nishino, Masami
    Tanouchi, Jun
    [J]. JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2023, 66 (09) : 2021 - 2030
  • [40] Ablation index-guided ablation versus second-generation cryoballoon for first pulmonary vein isolation in atrial fibrillation
    Felix-Oliveira, A.
    Carmo, J.
    Carmo, P.
    Cavaco, D.
    Fontes, A.
    Rodrigues, G.
    Matos, D.
    Moscoso Costa, F.
    Bello Morgado, F.
    Adragao, P.
    Carvalho, S.
    [J]. EUROPEAN HEART JOURNAL, 2019, 40 : 1212 - 1212