Miniature and flexible Bazooka balun for high-field MRI

被引:1
|
作者
Chai, Shuyang [1 ,2 ]
Yan, Xinqiang [1 ,2 ,3 ,4 ]
机构
[1] Vanderbilt Univ, Dept Elect & Comp Engn, Nashville, TN 37232 USA
[2] Vanderbilt Univ, Med Ctr, Inst Imaging Sci, Nashville, TN 37232 USA
[3] Vanderbilt Univ, Med Ctr, Dept Radiol & Radiol Sci, Nashville, TN 37232 USA
[4] Vanderbilt Univ, Inst Imaging Sci, Med Ctr North, 1161 21st Ave SouthD-2205, Nashville, TN 37232 USA
关键词
Balun; RF coil; Flexible coil; Common-mode current; SNR; ARRAY; COILS;
D O I
10.1016/j.jmr.2023.107577
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Flexible coils offer improved patient comfort and better imaging quality. However, rigid and bulky baluns in RF coils limit flexibility and manufacturing. A miniaturized and flexible balun design was proposed to address this issue. It replaced rigid components with an ultra-flexible rubber tube and a flexible coaxial capacitor. Simulations validated the concept, and bench tests confirmed its performance, including a measured common-mode rejection ratio of -15.8 dB. The flexible balun was integrated into a 4-channel coil array, evaluating impedance changes caused by the "hand effect." Compared to coils without the balun, the flexible coil with the proposed balun showed improved robustness in impedance matching and inter-element couplings. Transmit efficiency of the flexible coil with the balun was compared to coils without a balun and with a rigid, shielded cable trap. Results demonstrated that the proposed balun circuit maintained high transmit efficiency. Overall, the flexible balun design offers a promising solution for improving the flexibility and performance of RF coil arrays in MRI applications.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] HIGH-FIELD MRI OF PRIMARY GALLBLADDER CARCINOMA
    WILBUR, AC
    GYI, B
    RENIGERS, SA
    GASTROINTESTINAL RADIOLOGY, 1988, 13 (02): : 142 - 144
  • [22] Detecting breast microcalcifications with high-field MRI
    de Leeuw, Hendrik
    Stehouwer, Bertine L.
    Bakker, Chris J. G.
    Klomp, Dennis W. J.
    van Diest, Paul J.
    Luijten, Peter R.
    Seevinck, Peter R.
    van den Bosch, Maurice A. A. J.
    Viergever, Max A.
    Veldhuis, Wouter B.
    NMR IN BIOMEDICINE, 2014, 27 (05) : 539 - 546
  • [23] Heating of Coils and Parts in High-field MRI
    Murphy-Boesch, Joseph
    EMAGRES, 2020, 9 (01): : 7 - 19
  • [24] High-Field MRI Advantages and Applications in Rheumatology
    Cheng, Karen Y.
    Jerban, Saeed
    Bae, Won C.
    Fliszar, Evelyne
    Chung, Christine B.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2024, 62 (05) : 837 - 847
  • [25] MRI in rheumatoid arthritis of the hands: Comparison of high-field and low field MRI
    Faouli, B
    Zaim, S
    Peterty, CG
    Lynch, JA
    Fan, B
    Eve, KH
    Genant, KH
    ARTHRITIS AND RHEUMATISM, 2001, 44 (09): : S224 - S224
  • [26] Low-field MRI can be more sensitive than high-field MRI
    Coffey, Aaron M.
    Truong, Milton L.
    Chekmenev, Eduard Y.
    JOURNAL OF MAGNETIC RESONANCE, 2013, 237 : 169 - 174
  • [27] MRI in rheumatoid arthritis of the hands: Comparison of high-field and low-field MRI
    Taouli, BA
    Zaim, S
    Lynch, JA
    Peterfy, CG
    Stork, A
    Fan, B
    RADIOLOGY, 2001, 221 : 523 - 523
  • [28] HIGH-FIELD STRENGTH MRI OF THE SPINE WITH SURGICAL CORRELATION
    WEINDLING, SM
    PRESS, GA
    HESSELINK, JR
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1987, 8 (05) : 966 - 966
  • [29] Active Phased Array Techniques for High-Field MRI
    Yazdanbakhsh, Pedram
    Solbach, Klaus
    2009 3RD EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION, VOLS 1-6, 2009, : 1305 - 1309
  • [30] A traveling-wave approach to high-field MRI
    Wilson, Mark
    PHYSICS TODAY, 2009, 62 (04) : 15 - 15