Development and validation of a stability-indicating, single HPLC method for sacubitril-valsartan and their stereoisomers and identification of forced degradation products using LC-MS/MS
被引:5
|
作者:
Vijaykumar, Cholleti
论文数: 0引用数: 0
h-index: 0
机构:
Dr Reddys Labs Ltd, Act Pharmaceut Ingredients, IPDO, Hyderabad, India
JNT Univ, Dept Chem, Hyderabad, India
Dr Reddys Labs Ltd, Act Pharmaceut Ingredients, IPDO Bachupally, Hyderabad, IndiaDr Reddys Labs Ltd, Act Pharmaceut Ingredients, IPDO, Hyderabad, India
Vijaykumar, Cholleti
[1
,2
,5
]
Kumar, Yalavarti Ravindra
论文数: 0引用数: 0
h-index: 0
机构:
RA Chem Pharm Ltd, Hyderabad, IndiaDr Reddys Labs Ltd, Act Pharmaceut Ingredients, IPDO, Hyderabad, India
The aim of this research work was to develop and validate a stability-indicating, single reversed-phase HPLC method for the separation of five impurities, including enantiomers, diastereomers, and degradation products in sacubitril-valsartan tablets. The method was developed using a Chiralcel OJ-RH column (150 x 4.6 mm, 5 mu m) at 45 degrees C with a gradient program of (T/%B) 0.01/25, 10.0/25, 25/38, 37.0/45, 39.0/25, and 45.0/25 at a flow rate of 0.8 ml/min. Mobile phase A consisted of 1 ml of trifluoroacetic acid in 1000 ml of Milli-Q water. Mobile phase B consisted of 1 ml of trifluoroacetic acid in a mixture of acetonitrile and methanol in the ratio of 950:50 (v/v). Sacubitril, valsartan, and their five impurities were monitored at 254 nm. Degradation was not observed when sacubitril-valsartan was subjected to heat, light, hydrolytic, and oxidation conditions. In acid degradation study (1 N HCl/60 degrees C/2 h) impurity 1 (m/z 383.44) was formed, and in base degradation study (0.1 N NaOH/40 degrees C/1 h) impurities 1 and 5 (m/z 265.35) were formed; both impurities were confirmed using LC-MS. The degradation products, enantiomers, and diastereomers were well separated from sacubitril and valsartan, proving the stability-indicating power of the method. The developed method was validated per the International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use guidelines. The inter- and intra-day percentage relative standard deviation for sacubitril, valsartan, and their five impurities was less than 5.2%, recovery of the five impurities was between 93 and 105%, and linearity was >= 0.999. The limit of detection was 0.030-0.048 mu g/ml, and the limit of quantification was 0.100-0.160 mu g/ml.
机构:
School of Advance Sciences, Vellore Institute of technology (VIT)School of Advance Sciences, Vellore Institute of technology (VIT)
Prashant S.Devrukhakar
M.Shiva Shankar
论文数: 0引用数: 0
h-index: 0
机构:
School of Advance Sciences, Vellore Institute of technology (VIT)School of Advance Sciences, Vellore Institute of technology (VIT)
M.Shiva Shankar
G.Shankar
论文数: 0引用数: 0
h-index: 0
机构:
National Centre for Mass Spectrometry, CSIR-Indian Institute of Chemical TechnologySchool of Advance Sciences, Vellore Institute of technology (VIT)
G.Shankar
R.Srinivas
论文数: 0引用数: 0
h-index: 0
机构:
National Centre for Mass Spectrometry, CSIR-Indian Institute of Chemical TechnologySchool of Advance Sciences, Vellore Institute of technology (VIT)