Transient elastography with controlled attenuation parameter versus two-dimensional shear wave elastography with attenuation imaging for the evaluation of hepatic steatosis and fibrosis in NAFLD

被引:2
|
作者
Seo, Jung Wook [1 ]
Kim, Youe Ree [2 ]
Jang, Jong Keon [3 ,4 ]
Kim, So Yeon [3 ,4 ]
Cho, Young Youn [5 ]
Lee, Eun Sun [6 ]
Lee, Dong Ho [7 ,8 ]
机构
[1] Inje Univ, Ilsan Paik Hosp, Dept Radiol, Coll Med, Goyang, South Korea
[2] Wonkwang Univ, Wonkwang Univ Hosp, Coll Med, Dept Radiol, Iksan, South Korea
[3] Univ Ulsan, Coll Med, Asan Med Ctr, Dept Radiol, Seoul, South Korea
[4] Univ Ulsan, Res Inst Radiol, Coll Med, Seoul, South Korea
[5] Chung Ang Univ Hosp, Dept Internal Med, Seoul, South Korea
[6] Chung Ang Univ Hosp, Dept Radiol, Seoul, South Korea
[7] Seoul Natl Univ Hosp, Dept Radiol, Seoul, South Korea
[8] Seoul Natl Univ Hosp, Dept Radiol, 101 Daehak Ro, Seoul 03080, South Korea
关键词
Liver cirrhosis; Fatty liver; Elasticity imaging techniques; FATTY LIVER-DISEASE; NONINVASIVE ASSESSMENT; CLINICAL-PRACTICE; PERFORMANCE; PREVALENCE; GUIDELINES; ULTRASOUND;
D O I
10.14366/usg.22212
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This study compared the controlled attenuation parameter (CAP) to attenuation imaging (ATI) in the diagnosis of steatosis and transient elastography (TE) to two-dimensional shear wave elastography (2D-SWE) for the diagnosis of fibrosis in a prospectively constructed nonalcoholic fatty liver disease (NAFLD) patient cohort. Methods: Participants who underwent TE with CAP were included from a previously constructed NAFLD cohort with multiparametric ultrasound data. The degree of hepatic steatosis and stage of liver fibrosis were assessed. Diagnostic performance was evaluated using the area under the receiver operating characteristic curve (AUROC) for the grades of steatosis (S1-3) and fibrosis (F0-F4).Results: There were 105 participants. The distribution of hepatic steatosis grades (S0-S3) and liver fibrosis stages (F0-F4) was as follows: S0, n=34; S1, n=41; S2, n=22; S3, n=8; F0, n=63; F1, n=25; F2, n=5; F3, n=7; and F4, n=5. No significant difference was found between CAP and ATI in detecting >_S1 (AUROC: 0.93 vs. 0.93, P=0.956) or >_S2 (0.94 vs. 0.94, P=0.769). However, the AUROC of ATI in detecting >_S3 was significantly higher than that of CAP (0.94 vs. 0.87, P=0.047). Regarding the detection of liver fibrosis, no significant difference was found between TE and 2D-SWE. The AUROCs of TE and 2D-SWE were as follows: >_F1, 0.94 vs. 0.89 (P=0.107); >_F2, 0.89 vs. 0.90 (P=0.644); >_F3, 0.91 vs. 0.90 (P=0.703); and >_F4, 0.88 vs. 0.92 (P=0.209).Conclusion: 2D-SWE and TE showed comparable diagnostic performance in assessing liver fibrosis, and ATI provided significantly better performance in detecting >_S3 steatosis than CAP.
引用
收藏
页码:421 / 431
页数:11
相关论文
共 50 条
  • [21] Liver Steatosis: Better Predictor of CKD in MAFLD Than Liver Fibrosis as Determined by Transient Elastography With Controlled Attenuation Parameter
    Marc, Luciana
    Mihaescu, Adelina
    Lupusoru, Raluca
    Grosu, Iulia
    Gadalean, Florica
    Bob, Flaviu
    Chisavu, Lazar
    Olariu, Nicu
    Tucicovschi, Vlad
    Timar, Bogdan
    Sporea, Ioan
    Timar, Romulus
    Schiller, Adalbert
    FRONTIERS IN MEDICINE, 2022, 8
  • [22] The Prevalence of Liver Allograft Steatosis Diagnosed By Transient Elastography with Controlled Attenuation Parameter and Its Predictors
    Chayanupatkul, Maneerat
    Dasani, Divya
    Schiano, Thomas D.
    HEPATOLOGY, 2018, 68 : 690A - 690A
  • [23] INTEROBSERVER CONCORDANCE IN CONTROLLED ATTENUATION PARAMETER (CAP) MEASUREMENT, A NOVEL TOOL FOR THE ASSESSMENT OF HEPATIC STEATOSIS BASED ON TRANSIENT ELASTOGRAPHY
    Recio, E.
    Neukam, K.
    Cifuentes, C.
    Mancebo, M.
    Macias, J.
    Almeida, C.
    Merchante, N.
    Mira, J. A.
    Rivero-Juarez, A.
    Pineda, J. A.
    JOURNAL OF HEPATOLOGY, 2013, 58 : S544 - S544
  • [24] Interconversion of elasticity measurements between two-dimensional shear wave elastography and transient elastography
    Kim, Yeun-Yoon
    Kim, Myung-Joon
    Shin, Hyun Joo
    Yoon, Haesung
    Kim, Ha Yan
    Lee, Mi-Jung
    MEDICAL ULTRASONOGRAPHY, 2018, 20 (02) : 127 - 133
  • [25] Two-dimensional shear wave elastography and ultrasound-guided attenuation parameter for progressive non-alcoholic steatohepatitis
    Kuroda, Hidekatsu
    Fujiwara, Yudai
    Abe, Tamami
    Nagasawa, Tomoaki
    Oguri, Takuma
    Noguchi, Sachiyo
    Kamiyama, Naohisa
    Takikawa, Yasuhiro
    PLOS ONE, 2021, 16 (04):
  • [26] Assessment of hepatic fibrosis by vibration-controlled transient elastography and MR elastography have equivalent diagnostic performance, but in the assessment of hepatic steatosis, MRI PDFF methods are better than controlled attenuation parameter in over
    Nogami, Asako
    Iwaki, Michihiro
    Kobayashi, Takashi
    Kessoku, Takaomi
    Honda, Yasushi
    Ogawa, Yuji
    Imajo, Kento
    Kirikoshi, Hiroyuki
    Saito, Satoru
    Nakajima, Atsushi
    Yoneda, Masato
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2021, 36 : 246 - 246
  • [27] Vibration-Controlled Transient Elastography and Controlled Attenuation Parameter for the Diagnosis of Liver Steatosis and Fibrosis in Patients with Nonalcoholic Fatty Liver Disease
    Zenovia, Sebastian
    Stanciu, Carol
    Sfarti, Catalin
    Singeap, Ana-Maria
    Cojocariu, Camelia
    Girleanu, Irina
    Dimache, Mihaela
    Chiriac, Stefan
    Muzica, Cristina Maria
    Nastasa, Robert
    Huiban, Laura
    Cuciureanu, Tudor
    Trifan, Anca
    DIAGNOSTICS, 2021, 11 (05)
  • [28] Non-invasive diagnosis of liver steatosis using controlled attenuation parameter (CAP) and transient elastography
    de Ledinghen, Victor
    Vergniol, Julien
    Foucher, Juliette
    Merrouche, Wassil
    le Bail, Brigitte
    LIVER INTERNATIONAL, 2012, 32 (06) : 911 - 918
  • [29] Fibroscan controlled attenuation parameter assessment of liver steatosis and fibrosis in NAFLD
    Yuan, Lili
    Zhang, Rui
    Zhu, Na
    Cao, Ping
    JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2013, 28 : 849 - 849
  • [30] Changes in liver steatosis evaluated by transient elastography with the controlled attenuation parameter in HIV-infected patients
    Macias, J.
    Real, L. M.
    Rivero-Juarez, A.
    Merchante, N.
    Camacho, A.
    Neukam, K.
    Rivero, A.
    Mancebo, M.
    Pineda, J. A.
    HIV MEDICINE, 2016, 17 (10) : 766 - 773