Operational flexibility and operation optimization of CHP units supplying electricity and two-pressure steam

被引:20
|
作者
Liu, Miaomiao [1 ]
Liu, Ming [1 ]
Chen, Weixiong [1 ]
Yan, Junjie [1 ]
机构
[1] Xi An Jiao Tong Univ, State Key Lab Multiphase Flow Power Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
CHP; Constraint; Double-extraction heating unit; Feasible operation domain; Energy and exergy efficiencies; COMBINED HEAT; ECONOMIC-DISPATCH; POWER-SYSTEM; ENERGY; PERFORMANCE; INTEGRATION; ALGORITHM; BOILERS; STORAGE; MODEL;
D O I
10.1016/j.energy.2022.125988
中图分类号
O414.1 [热力学];
学科分类号
摘要
Combined heat and power (CHP) is an effective way of enhancing the energy efficiency of thermal power plants. Double-extraction CHP, a typical kind of CHP unit, can supply two-pressure steam to district heating and industry users. The feasible operation domain of a double-extraction CHP unit, which has many constraints, is essential for the flexible operation enhancement and operation optimization of CHP units. In this study, a method is proposed to express the feasible operation domain of the double-extraction CHP unit with a 3D operation domain with six boundary surfaces, and the operating boundary constraints of the double-extraction unit are elaborated. Then, a reference 1000-MW double-extraction CHP case is analyzed, and the operation domains and energy consumption characteristics of three typical heating modes are analyzed. The optimal scheme of heating modes is obtained under different power loads. When the power load is between 783.09 MW and 936.06 MW, Heating Mode 4 (cold reheat steam for HLS1, hot reheat steam for HLS2) has the highest exergy efficiency. This research provides theoretical guidance and a basis for the operation of the CHP unit supplying power load and two heat loads simultaneously.
引用
收藏
页数:16
相关论文
共 47 条
  • [41] Optimization on coordinate control strategy assisted by high-pressure extraction steam throttling to achieve flexible and efficient operation of thermal power plants
    Wang, Zhu
    Liu, Ming
    Yan, Hui
    Yan, Junjie
    ENERGY, 2022, 244
  • [42] Two-stage optimization model for day-ahead scheduling of electricity- heat microgrids with solid electric thermal storage considering heat flexibility
    Ma, Yinghao
    Wang, Shuai
    Yang, Hejun
    Zhang, Dabo
    Shen, Yuming
    JOURNAL OF ENERGY STORAGE, 2024, 95
  • [43] Two-Layer Optimization Scheduling Model of Integrated Electricity and Natural Gas Energy System Considering the Feasibility of Gas-Fired Units Reserve
    Zhou, Xueting
    Bao, Yu-Qing
    Ji, Tongzhou
    Wang, Qi
    IEEE ACCESS, 2020, 8 : 40337 - 40346
  • [44] Two-stage robust optimization for optimal operation of hybrid hydrogen-electricity storage system considering ladder-type carbon trading
    Zhang, Luliang
    Hua, Dingyan
    Zheng, J. H.
    Li, Zhigang
    JOURNAL OF ENERGY STORAGE, 2024, 100
  • [45] A two-stage energy management for heat-electricity integrated energy system considering dynamic pricing of Stackelberg game and operation strategy optimization
    Huang, Yujing
    Wang, Yudong
    Liu, Nian
    ENERGY, 2022, 244
  • [46] FEATURES OF HEAT TRANSFER STUDY OF TWO-PHASE FLOW IN FURNACE WALL TUBE FOR VARIABLE PRESSURE OPERATION SUPERCRITICAL ONCE-THROUGH STEAM GENERATOR.
    Hori, Masayoshi
    Matsumoto, Seiichi
    Nakada, Tetsuro
    IHI Engineering Review (English Edition), 1982, 15 (01): : 31 - 38
  • [47] Multi-mode operation of a novel dual-pressure steam rankine cycle system recovering multi-grade waste heat from a marine two-stroke engine equipped with the high-pressure exhaust gas recirculation system
    Tang, Yujun
    Feng, Jinfeng
    Wang, Dawei
    Zhu, Sipeng
    Bai, Shuzhan
    Li, Guoxiang
    ENERGY, 2024, 301