Data center energy conservation study utilizing loop heat pipes as a chip-level cooling technique and its industrial application

被引:24
|
作者
Xue, Zhi Hu [1 ]
Ai, Bang Cheng [1 ]
Qu, Wei [1 ]
机构
[1] China Acad Aerosp Aerodynam, Beijing 100074, Peoples R China
关键词
Electronics cooling; Data center; Energy saving; Loop heat pipe; Chip-level cooling; Thermal management; AIR-SIDE ECONOMIZERS; FLAT EVAPORATOR; SYSTEMS; DESIGN; PERFORMANCE; FLOW;
D O I
10.1016/j.applthermaleng.2022.119715
中图分类号
O414.1 [热力学];
学科分类号
摘要
The thermal management and energy consumption for data centers became an increasing challenge due to a significant increase in their number, size and power density in modern information and digitization age. The electricity using by cooling system contributed the important fraction of energy consumption in datacenters, and it is of great significance to carry out the research of new cooling technologies to improve the cooling efficiency of datacenters. This paper initiatively presents the basic energy conservation principle of chip-level cooling technique based on the loop heat pipe (LHP) for natural cooling throughout a year. An energy-saving theoretical evaluation model based on the LHP chip-level cooling method is developed for assessing the energy utilizing efficiency and energy-saving levels in datacenters. Two kinds of real computer servers using two water-cooling LHPs with flat evaporator are introduced. The evaporator volume of a LHP is 54 x 44 x 12 mm3. The tests show that the servers work safely with the inlet water temperature of 40 degrees C and flow rate of 0.027 m3/h in the condenser of LHP. Lastly, the applications in two industrial data centers based on the LHP chip-level cooling technique are practiced. The annual cooling-PUE of a cloud-computing datacenter in Hohhot city is 1.053, and the annual PUE of a supercomputer-center in Beijing city is 1.15. Their operation data both show that the energy savings of the cooling system and the whole data center could be up to 81 % and 30 % respectively compared to the traditional CRAH cooling technique, which are in accordance with the predicted results of theoretical evaluation model.
引用
收藏
页数:13
相关论文
共 22 条
  • [21] An experimental and numerical study on the thermal performance of a loop thermosyphon integrated with latent thermal energy storage for emergency cooling in a data center
    Ma, Xiaowei
    Zhang, Quan
    Zou, Sikai
    ENERGY, 2022, 253
  • [22] A novel data center air conditioner and its application scheme balancing high-efficiency cooling and waste heat recovery: Environmental and economic analysis
    Zhang, Ce
    Han, Zongwei
    Dong, Jiaxiang
    Li, Mengyi
    Zhang, Yiqi
    Li, Xiuming
    Wen, Zhenwu
    Wang, Qinghai
    ENERGY, 2024, 291