Observation of discrepancy between the degradation of polymer scaffolds in vitro and in vivo according to high-resolution ultrasound technique

被引:5
|
作者
Morokov, Egor [1 ,4 ]
Yabbarov, Nikita [1 ]
Sedush, Nikita [2 ]
Bogachenkov, Alexey [1 ]
Malykhin, Alexander [3 ]
Demina, Varvara [2 ]
Azarkevich, Pavel [2 ]
Nikolskaya, Elena [1 ]
Chirkina, Margarita [1 ]
Sokol, Maria [1 ]
机构
[1] RAS, Emanuel Inst Biochem Phys, Kosygina St 4, Moscow 119334, Russia
[2] RAS, Enikolopov Inst Synthet Polymer Mat, Profsoyuznaya St 70, Moscow 117393, Russia
[3] Bauman Moscow State Tech Univ, Sci & Educ Ctr Robot, 2nd Baumanskaya St 5-1, Moscow 105005, Russia
[4] Russian Acad Sci, Lab Acoust Microscopy, Emanuel Inst Biochem Phys, Kosygina St,4, Moscow 119334, Russia
关键词
In vivo monitoring; Ultrasound imaging; Biodegradable polymers; PLGA; Hydrolytic degradation; Microstructure; Elastic properties; VASCULATURE;
D O I
10.1016/j.eurpolymj.2023.112248
中图分类号
O63 [高分子化学(高聚物)];
学科分类号
070305 ; 080501 ; 081704 ;
摘要
Biocompatible, biodegradable polymers are actively used as drug delivery systems and as tissue engineering scaffolds. The hydrothermal aging of polymers, including degradation of the microstructure and changes of mechanical properties directly depends on environmental conditions. In vitro studies in a model media cannot contain and describe all the factors influencing the polymer degradation in a living organism. It seems promising to study the processes of changes in the microstructure and elastic properties of polymer implants in vivo in dynamics. Here, we present data from the application of new experimental equipment for high-resolution ultrasound imaging of polymer degradation in vivo. Ultrasonic results include images of the transformation of volumetric microstructure and changes in elastic properties in dynamics. The method was verified on a rapidly degradable polymer poly(D,L-lactide-co-glycolide). We assess and compare the evolution of volume microstructure, elastic properties and molecular weight of the polymer weekly for 1.5 months of incubation in vitro and in vivo. We found that the in vivo degradation process occurs with a delay of 2 weeks compared to the hydrothermal aging in vitro.
引用
收藏
页数:7
相关论文
共 50 条
  • [31] MEASUREMENT OF HIGH-FREQUENCY ULTRASOUND IN LIQUIDS USING HIGH-RESOLUTION BRAGG REFLECTION TECHNIQUE
    TAKAGI, K
    NEGISHI, K
    ULTRASONICS, 1978, 16 (06) : 259 - 263
  • [32] Rare Variant of Vastus Medialis Detected in vivo by Ultrasound and Confirmed by High-resolution MRI
    Benjafield, Anastasia
    Howe, Franklyn A.
    Killingback, Alban
    Adds, Philip J.
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2014, 26 (01) : 165 - 166
  • [33] QUANTITATIVE ASSESSMENT OF GINGIVAL INFLAMMATION USING HIGH-RESOLUTION ULTRASOUND EX-VIVO
    Sayed, Ahmed M.
    Lamarck, Rachel
    Cruz, Elisa
    Chaves, Eros
    Mukdadi, Osama M.
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2018, 18 (03)
  • [34] MOLECULAR ACOUSTIC ANGIOGRAPHY: A NEW TECHNIQUE FOR HIGH-RESOLUTION SUPERHARMONIC ULTRASOUND MOLECULAR IMAGING
    Shelton, Sarah E.
    Lindsey, Brooks D.
    Tsuruta, James K.
    Foster, F. Stuart
    Dayton, Paul A.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (03): : 769 - 781
  • [35] ULTRA HIGH-RESOLUTION TRANSRECTAL ULTRASOUND: A NOVEL TECHNIQUE FOR ENHANCED PROSTATE CANCER IMAGING
    Mullins, Jeffrey
    Cornish, Toby
    Reese, Adam
    Fradin, Joel
    Mettee, Lynda
    Askin, Frederic
    Luck, Rachael
    DeMarzo, Angelo
    Epstein, Jonathan
    Pavlovich, Christian
    JOURNAL OF UROLOGY, 2012, 187 (04): : E891 - E891
  • [36] A high-resolution technique for ultrasound harmonic imaging using sparse representations in Gabor frames
    Michailovich, O
    Adam, D
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (12) : 1490 - 1503
  • [37] ITERATIVE, PARAMETRIC SPECTRAL ESTIMATION TECHNIQUE FOR HIGH-RESOLUTION PULSE-ECHO ULTRASOUND
    MEYER, CR
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1979, 26 (04) : 207 - 212
  • [38] High-resolution intravascular ultrasound using optical coherence tomography technique: basic study
    Taki, H.
    Kudo, M.
    Shiina, T.
    Taki, K.
    Sato, T.
    EUROPEAN HEART JOURNAL, 2014, 35 : 1149 - 1149
  • [39] In-vivo observation of cells with a combined high-resolution multiphoton-acoustic scanning microscope
    Schenkl, Selma
    Weiss, Eike C.
    Stracke, Frank
    Saijer, Daniel
    Stark, Martin
    Riemann, Iris
    Lemor, Robert M.
    Koenig, Karsten
    MICROSCOPY RESEARCH AND TECHNIQUE, 2007, 70 (05) : 476 - 480
  • [40] In vitro and in vivo metabolism of 3-quinuclidinyl benzilate by high-resolution mass spectrometry
    Uher, Martin
    Mzik, Martin
    Karasova, Jana Zd'arova
    Herman, David
    Cechova, Lenka
    Dlabkova, Alzbeta
    Mrkvicova, Alena
    Hroch, Milos
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2020, 190