Fully Automated Longitudinal Assessment of Renal Stone Burden on Serial CT Imaging Using Deep Learning

被引:7
|
作者
Mukherjee, Pritam [1 ]
Lee, Sungwon [1 ]
Elton, Daniel C. [1 ]
Nakada, Stephen Y. [2 ]
Pickhardt, Perry J. [2 ]
Summers, Ronald M. [1 ,3 ]
机构
[1] Natl Inst Hlth Clin Ctr, Imaging Biomarkers & Comp Aided Diag Lab, Dept Radiol & Imaging Sci, Bethesda, MD USA
[2] Univ Wisconsin, Sch Med & Publ Hlth, Dept Radiol, Madison, WI USA
[3] Natl Inst Hlth Clin Ctr, Dept Radiol & Imaging Sci, Imaging Biomarkers & Comp Aided Diag Lab, Bldg 10,Room 1C224D,10 Ctr Dr, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
renal stone burden; interval change; longitudinal analysis; deep learning; COMPUTED-TOMOGRAPHY; KIDNEY-STONES; PLAIN RADIOGRAPHY; SPIRAL CT; CALCULI; QUANTIFICATION; SIZE;
D O I
10.1089/end.2023.0066
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Use deep learning (DL) to automate the measurement and tracking of kidney stone burden over serial CT scans.Materials and Methods: This retrospective study included 259 scans from 113 symptomatic patients being treated for urolithiasis at a single medical center between 2006 and 2019. These patients underwent a standard low-dose noncontrast CT scan followed by ultra-low-dose CT scans limited to the level of the kidneys. A DL model was used to detect, segment, and measure the volume of all stones in both initial and follow-up scans. The stone burden was characterized by the total volume of all stones in a scan (SV). The absolute and relative change of SV, (SVA and SVR, respectively) over serial scans were computed. The automated assessments were compared with manual assessments using concordance correlation coefficient (CCC), and their agreement was visualized using Bland-Altman and scatter plots.Results: Two hundred twenty-eight out of 233 scans with stones were identified by the automated pipeline; per-scan sensitivity was 97.8% (95% confidence interval [CI]: 96.0-99.7). The per-scan positive predictive value was 96.6% (95% CI: 94.4-98.8). The median SV, SVA, and SVR were 476.5 mm(3), -10 mm(3), and 0.89, respectively. After removing outliers outside the 5th and 95th percentiles, the CCC measuring agreement on SV, SVA, and SVR were 0.995 (0.992-0.996), 0.980 (0.972-0.986), and 0.915 (0.881-0.939), respectivelyConclusions: The automated DL-based measurements showed good agreement with the manual assessments of the stone burden and its interval change on serial CT scans.
引用
收藏
页码:948 / 955
页数:8
相关论文
共 50 条
  • [31] Fully Automated FDG and PSMA Lesion Segmentation in PET Imaging via Deep Learning
    Pires, M.
    Ferrara, D.
    Beyer, T.
    Sundar, L. K. Shiyam
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2024, 51 : S348 - S348
  • [32] Fully Automatic Volume Measurement of the Spleen at CT Using Deep Learning
    Humpire-Mamani, Gabriel E.
    Bukala, Joris
    Scholten, Ernst T.
    Prokop, Mathias
    van Ginneken, Bram
    Jacobs, Colin
    RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2020, 2 (04) : 1 - 10
  • [33] Fully Automated Pancreatic Cancer Tumor Analysis in CT Images Using Artificial Intelligence and Deep Learning Neural Networks
    Asadpour, V.
    Parker, R. A.
    Sampson, S. J.
    Chen, W.
    Wu, B. U.
    PANCREAS, 2019, 48 (10) : 1404 - 1405
  • [34] A deep learning system for automated kidney stone detection and volumetric segmentation on noncontrast CT scans
    Elton, Daniel C.
    Turkbey, Evrim B.
    Pickhardt, Perry J.
    Summers, Ronald M.
    MEDICAL PHYSICS, 2022, 49 (04) : 2545 - 2554
  • [35] Deep Learning-Based Fully Automated Segmentation of Regional Muscle Volume and Spatial Intermuscular Fat Using CT
    Zhang, Rui
    He, Aiting
    Xia, Wei
    Su, Yongbin
    Jian, Junming
    Liu, Yandong
    Guo, Zhe
    Shi, Wei
    Zhang, Zhenguang
    He, Bo
    Cheng, Xiaoguang
    Gao, Xin
    Liu, Yajun
    Wang, Ling
    ACADEMIC RADIOLOGY, 2023, 30 (10) : 2280 - 2289
  • [36] Deep learning enables fully automated mitotic density assessment in breast cancer histopathology
    Balkenhol, M.
    Bult, P.
    Tellez, D.
    Vreuls, W.
    Clahsen, P.
    Ciompi, F.
    van der Laak, J.
    VIRCHOWS ARCHIV, 2019, 475 : S58 - S59
  • [37] Deep learning enables fully automated mitotic density assessment in breast cancer histopathology
    Balkenhol, M.
    Bult, P.
    Tellez, D.
    Vreuls, W.
    Clahsen, P.
    Ciompi, F.
    Van der Laak, J.
    EUROPEAN JOURNAL OF CANCER, 2020, 138 : S86 - S86
  • [38] A fully-automated paper ECG digitisation algorithm using deep learning
    Huiyi Wu
    Kiran Haresh Kumar Patel
    Xinyang Li
    Bowen Zhang
    Christoforos Galazis
    Nikesh Bajaj
    Arunashis Sau
    Xili Shi
    Lin Sun
    Yanda Tao
    Harith Al-Qaysi
    Lawrence Tarusan
    Najira Yasmin
    Natasha Grewal
    Gaurika Kapoor
    Jonathan W. Waks
    Daniel B. Kramer
    Nicholas S. Peters
    Fu Siong Ng
    Scientific Reports, 12
  • [39] Fully Automated Detection and Quantification of Macular Fluid in OCT Using Deep Learning
    Schlegl, Thomas
    Waldstein, Sebastian M.
    Bogunovic, Hrvoje
    Endstrasser, Franz
    Sadeghipour, Amir
    Philip, Ana-Maria
    Podkowinski, Dominika
    Gerendas, Bianca S.
    Langs, Georg
    Schmidt-Erfurth, Ursula
    OPHTHALMOLOGY, 2018, 125 (04) : 549 - 558
  • [40] A fully-automated paper ECG digitisation algorithm using deep learning
    Wu, Huiyi
    Patel, Kiran Haresh Kumar
    Li, Xinyang
    Zhang, Bowen
    Galazis, Christoforos
    Bajaj, Nikesh
    Sau, Arunashis
    Shi, Xili
    Sun, Lin
    Tao, Yanda
    Al-Qaysi, Harith
    Tarusan, Lawrence
    Yasmin, Najira
    Grewal, Natasha
    Kapoor, Gaurika
    Waks, Jonathan W.
    Kramer, Daniel B.
    Peters, Nicholas S.
    Ng, Fu Siong
    SCIENTIFIC REPORTS, 2022, 12 (01)