Fully Automated Longitudinal Assessment of Renal Stone Burden on Serial CT Imaging Using Deep Learning

被引:7
|
作者
Mukherjee, Pritam [1 ]
Lee, Sungwon [1 ]
Elton, Daniel C. [1 ]
Nakada, Stephen Y. [2 ]
Pickhardt, Perry J. [2 ]
Summers, Ronald M. [1 ,3 ]
机构
[1] Natl Inst Hlth Clin Ctr, Imaging Biomarkers & Comp Aided Diag Lab, Dept Radiol & Imaging Sci, Bethesda, MD USA
[2] Univ Wisconsin, Sch Med & Publ Hlth, Dept Radiol, Madison, WI USA
[3] Natl Inst Hlth Clin Ctr, Dept Radiol & Imaging Sci, Imaging Biomarkers & Comp Aided Diag Lab, Bldg 10,Room 1C224D,10 Ctr Dr, Bethesda, MD 20892 USA
基金
美国国家卫生研究院;
关键词
renal stone burden; interval change; longitudinal analysis; deep learning; COMPUTED-TOMOGRAPHY; KIDNEY-STONES; PLAIN RADIOGRAPHY; SPIRAL CT; CALCULI; QUANTIFICATION; SIZE;
D O I
10.1089/end.2023.0066
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Use deep learning (DL) to automate the measurement and tracking of kidney stone burden over serial CT scans.Materials and Methods: This retrospective study included 259 scans from 113 symptomatic patients being treated for urolithiasis at a single medical center between 2006 and 2019. These patients underwent a standard low-dose noncontrast CT scan followed by ultra-low-dose CT scans limited to the level of the kidneys. A DL model was used to detect, segment, and measure the volume of all stones in both initial and follow-up scans. The stone burden was characterized by the total volume of all stones in a scan (SV). The absolute and relative change of SV, (SVA and SVR, respectively) over serial scans were computed. The automated assessments were compared with manual assessments using concordance correlation coefficient (CCC), and their agreement was visualized using Bland-Altman and scatter plots.Results: Two hundred twenty-eight out of 233 scans with stones were identified by the automated pipeline; per-scan sensitivity was 97.8% (95% confidence interval [CI]: 96.0-99.7). The per-scan positive predictive value was 96.6% (95% CI: 94.4-98.8). The median SV, SVA, and SVR were 476.5 mm(3), -10 mm(3), and 0.89, respectively. After removing outliers outside the 5th and 95th percentiles, the CCC measuring agreement on SV, SVA, and SVR were 0.995 (0.992-0.996), 0.980 (0.972-0.986), and 0.915 (0.881-0.939), respectivelyConclusions: The automated DL-based measurements showed good agreement with the manual assessments of the stone burden and its interval change on serial CT scans.
引用
收藏
页码:948 / 955
页数:8
相关论文
共 50 条
  • [1] Fully Automated Segmentation of Head CT Neuroanatomy Using Deep Learning
    Cai, Jason C.
    Akkus, Zeynettin
    Philbrick, Kenneth A.
    Boonrod, Arunnit
    Hoodeshenas, Safa
    Weston, Alexander D.
    Rouzrokh, Pouria
    Conte, Gian Marco
    Zeinoddini, Atefeh
    Vogelsang, David C.
    Huang, Qiao
    Erickson, Bradley J.
    RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2020, 2 (05) : 1 - 12
  • [2] Automatic assessment of glioma burden: a deep learning algorithm for fully automated volumetric and bidimensional measurement
    Chang, Ken
    Beers, Andrew L.
    Bai, Harrison X.
    Brown, James M.
    Ly, K. Ina
    Li, Xuejun
    Senders, Joeky T.
    Kavouridis, Vasileios K.
    Boaro, Alessandro
    Su, Chang
    Bi, Wenya Linda
    Rapalino, Otto
    Liao, Weihua
    Shen, Qin
    Zhou, Hao
    Xiao, Bo
    Wang, Yinyan
    Zhang, Paul J.
    Pinho, Marco C.
    Wen, Patrick Y.
    Batchelor, Tracy T.
    Boxerman, Jerrold L.
    Arnaout, Omar
    Rosen, Bruce R.
    Gerstner, Elizabeth R.
    Yang, Li
    Huang, Raymond Y.
    Kalpathy-Cramer, Jayashree
    NEURO-ONCOLOGY, 2019, 21 (11) : 1412 - 1422
  • [3] Improved CT-based Osteoporosis Assessment with a Fully Automated Deep Learning Tool
    Pickhardt, Perry J.
    Nguyen, Thang
    Perez, Alberto A.
    Graffy, Peter M.
    Jang, Samuel
    Summers, Ronald M.
    Garrett, John W.
    RADIOLOGY-ARTIFICIAL INTELLIGENCE, 2022, 4 (05)
  • [4] Toward fully automated assessment of the central vein sign using deep learning
    Huelnhagen, T.
    Al Louzi, O.
    Fartaria, M. J.
    Daboul, L.
    Reich, D. S.
    Richiardi, J.
    Sati, P.
    Kober, T.
    MULTIPLE SCLEROSIS JOURNAL, 2021, 27 (2_SUPPL) : 461 - 462
  • [5] Deep learning model for automated kidney stone detection using coronal CT images
    Yildirim, Kadir
    Bozdag, Pinar Gundogan
    Talo, Muhammed
    Yildirim, Ozal
    Karabatak, Murat
    Acharya, U. Rajendra
    COMPUTERS IN BIOLOGY AND MEDICINE, 2021, 135
  • [6] A DEEP LEARNING ALGORITHM FOR FULLY AUTOMATED VOLUMETRIC MEASUREMENT OF MENINGIOMA BURDEN
    Cleveland, Mason
    Kim, Albert
    Patel, Jay
    McCall, Owen
    Liu, William
    Ahmed, Syed
    Bearce, Benjamin
    Chang, Ken
    De Sauvage, Magali
    Hoebel, Katharina
    Larson, Juliana
    Nayyar, Naema
    Pulido, Dagoberto
    Singh, Praveer
    Summers, Elizabeth
    Kalpathy-Cramer, Jayashree
    Plotkin, Scott R.
    Brastianos, Priscilla
    Bridge, Christopher
    Gerstner, Elizabeth
    NEURO-ONCOLOGY, 2023, 25
  • [7] Fully Automated Abdominal CT Biomarkers for Type 2 Diabetes Using Deep Learning
    Tallam, Hima
    Elton, Daniel C.
    Lee, Sungwon
    Wakim, Paul
    Pickhardt, Perry J.
    Summers, Ronald M.
    RADIOLOGY, 2022, 304 (01) : 85 - 95
  • [8] Assessment of deep learning technique for fully automated mandibular segmentation
    Yurdakurban, Ebru
    Sukut, Yagizalp
    Duran, Gokhan Serhat
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2025, 167 (02) : 242 - 249
  • [9] Fully Automated Deep Learning System for Bone Age Assessment
    Lee, Hyunkwang
    Tajmir, Shahein
    Lee, Jenny
    Zissen, Maurice
    Yeshiwas, Bethel Ayele
    Alkasab, Tarik K.
    Choy, Garry
    Do, Synho
    JOURNAL OF DIGITAL IMAGING, 2017, 30 (04) : 427 - 441
  • [10] Fully Automated Deep Learning System for Bone Age Assessment
    Hyunkwang Lee
    Shahein Tajmir
    Jenny Lee
    Maurice Zissen
    Bethel Ayele Yeshiwas
    Tarik K. Alkasab
    Garry Choy
    Synho Do
    Journal of Digital Imaging, 2017, 30 : 427 - 441