Comparison of incidental parathyroid tissue detection rates on pathology after total thyroidectomy performed with or without near-infrared autofluorescence imaging

被引:6
|
作者
Romero-Velez, Gustavo [1 ]
Avci, Seyma Nazli [2 ]
Isiktas, Gizem [1 ]
Ergun, Onuralp [1 ]
Akgun, Ege [1 ]
Muraveika, Liudmila [1 ]
Jin, Judy [1 ]
Heiden, Katherine [1 ]
Krishnamurthy, Vikram D. [1 ]
Shin, Joyce [1 ]
Siperstein, Allan [1 ]
Berber, Eren [1 ,3 ]
机构
[1] Cleveland Clin, Endocrinol & Metab Inst, Dept Endocrine Surg, Cleveland, OH USA
[2] Cleveland Clin Florida, Dept Gen Surg, Weston, FL USA
[3] Cleveland Clin, Endocrinol & Metab Inst, 9500 Euclid Ave,Mail Code F-20, Cleveland, OH 44195 USA
关键词
IDENTIFICATION; FLUORESCENCE; LOCALIZATION; GLANDS;
D O I
10.1016/j.surg.2023.05.047
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Near-infrared autofluorescence imaging is an adjunct to parathyroid identification. As it does not show perfusion, it is important to study its impact during thyroidectomy by measuring quantifiable data on parathyroid detection rather than function. The aim of this study was to compare incidental parathyroidectomy rates in patients undergoing total thyroidectomy with or without near-infrared autofluorescence.Methods: Retrospective study of patients who underwent total thyroidectomy between 2014 and 2022 at one center. Clinical parameters, including rates of incidental parathyroid tissue on pathology reports, were compared between near-infrared autofluorescence and non-near-infrared autofluorescence groups. Near-infrared autofluorescence was used to guide dissection (identification) and/or to confirm tissue as parathyroid (confirmation). Statistical analysis was done with Wilcoxon rank sum test and c2 analysis.Results: There were 300 patients in the near-infrared autofluorescence and 750 patients in the non-near-infrared autofluorescence group. The rate of incidental parathyroid tissue detection on final pathology was 13.3% (n = 40) in the near-infrared autofluorescence and 23.2% (n = 174) in the non-near-infrared autofluorescence group (P < .001). The rate of incidental parathyroid tissue detected on pathology with near-infrared autofluorescence decreased when used for identification and confirmation of para-thyroid tissue (30.0% to 13.4%, P < .001), but not when used for confirmation only (19.6% to 18.5%, P = .89). Impact of near-infra red autofluorescence in decreasing the rate of incidental parathyroid tissue was more profound for early (38.5% to 17.1%) versus mid-late career surgeons (20% to 13%).Conclusion: Our results suggest that the use of near-infrared autofluorescence may help decrease the rate of incidental parathyroid tissue detected on final pathology if used for both identification and confirmation of parathyroid glands during thyroidectomy.(c) 2023 Elsevier Inc. All rights reserved.
引用
收藏
页码:128 / 133
页数:6
相关论文
共 50 条
  • [21] In Reference to Near-Infrared Fluorescence Imaging in the Identification of Parathyroid Glands in Thyroidectomy
    Wang, Bin
    Zhu, Chun-Rong
    Wu, Jian
    LARYNGOSCOPE, 2021, 131 (05): : E1748 - E1748
  • [22] Biological imaging without autofluorescence in the second near-infrared region
    Diao, Shuo
    Hong, Guosong
    Antaris, Alexander L.
    Blackburn, Jeffrey L.
    Cheng, Kai
    Cheng, Zhen
    Dai, Hongjie
    NANO RESEARCH, 2015, 8 (09) : 3027 - 3034
  • [23] Biological imaging without autofluorescence in the second near-infrared region
    Shuo Diao
    Guosong Hong
    Alexander L. Antaris
    Jeffrey L. Blackburn
    Kai Cheng
    Zhen Cheng
    Hongjie Dai
    Nano Research, 2015, 8 : 3027 - 3034
  • [24] Investigation of near-infrared autofluorescence imaging for the detection of breast cancer
    Demos, SG
    Bold, R
    White, RD
    Ramsamooj, R
    IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 2005, 11 (04) : 791 - 798
  • [25] Label-free Intraoperative Parathyroid Localization With Near-Infrared Autofluorescence Imaging
    McWade, Melanie A.
    Paras, Constantine
    White, Lisa M.
    Phay, John E.
    Solorzano, Carmen C.
    Broome, James T.
    Mahadevan-Jansen, Anita
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2014, 99 (12): : 4574 - 4580
  • [26] Detection of Parathyroid Autofluorescence Using Near-Infrared Imaging: A Multicenter Analysis of Concordance Between Different Surgeons
    Kahramangil, Bora
    Dip, Fernando
    Benmiloud, Fares
    Falco, Jorge
    de La Fuente, Martin
    Verna, Silvina
    Rosenthal, Raul
    Berber, Eren
    ANNALS OF SURGICAL ONCOLOGY, 2018, 25 (04) : 957 - 962
  • [27] Procurement of Deceased Donor Parathyroid Glands With the Aid of Near-infrared Autofluorescence Imaging
    Ward, Casey J.
    Kelly, Yvonne M.
    Syed, Shareef M.
    Meier, Raphael P. H.
    Ando, Tadasuke
    Wisel, Steven A.
    Gardner, James M.
    Stock, Peter G.
    Duh, Quan-Yang
    TRANSPLANTATION DIRECT, 2022, 8 (04): : E1306
  • [28] Detection of Parathyroid Autofluorescence Using Near-Infrared Imaging: A Multicenter Analysis of Concordance Between Different Surgeons
    Bora Kahramangil
    Fernando Dip
    Fares Benmiloud
    Jorge Falco
    Martin de La Fuente
    Silvina Verna
    Raul Rosenthal
    Eren Berber
    Annals of Surgical Oncology, 2018, 25 : 957 - 962
  • [29] Use of Near-Infrared Autofluorescence Imaging During Thyroidectomy Associated with Improved Clinical Outcomes
    Guo, Feiyue
    Xu, Lei
    Zhang, Jing
    INDIAN JOURNAL OF SURGERY, 2022, 86 (Suppl 1) : 10 - 17
  • [30] Near-infrared autofluorescence of the parathyroid glands during thyroidectomy for the prevention of hypoparathyroidism: a prospective randomized clinical trial
    Wolf, Henning Wendelin
    Runkel, Norbert
    Limberger, Kathrin
    Nebiker, Christian Andreas
    LANGENBECKS ARCHIVES OF SURGERY, 2022, 407 (07) : 3031 - 3038