Sensitivity investigation of 100-MeV proton irradiation to SiGe HBT single event effect

被引:0
|
作者
Feng, Ya-Hui [1 ]
Guo, Hong-Xia [2 ,4 ]
Liu, Yi-Wei [2 ]
Ouyang, Xiao-Ping [1 ,4 ]
Zhang, Jin-Xin [3 ]
Ma, Wu-Ying [4 ]
Zhang, Feng-Qi [4 ]
Bai, Ru-Xue [2 ]
Ma, Xiao-Hua [1 ]
Hao, Yue [1 ]
机构
[1] Xidian Univ, Sch Microelect, State Key Lab Wide Bandgap Semicond Devices, Xian 710071, Peoples R China
[2] Xiangtan Univ, Sch Mat Sci & Engn, Xiangtan 411105, Peoples R China
[3] Xidian Univ, Sch Space Sci & Technol, Xian 710071, Peoples R China
[4] Northwest Inst Nucl Technol, State Key Lab Expt Simulat & Effects Strong Pulse, Xian 710024, Peoples R China
基金
中国国家自然科学基金;
关键词
silicon-germanium heterojunction bipolar transistor (SiGe HBT); 100-MeV proton; technology computer-aided design (TCAD); single event effect (SEE); 61.72.uf; 61.80.Ed; 61.80.-x; 61.80.Jh; TEMPERATURE-DEPENDENCE; TRANSIENTS; TECHNOLOGY; SIMULATION; LOGIC; DC;
D O I
10.1088/1674-1056/acf303
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
The single event effect (SEE) sensitivity of silicon-germanium heterojunction bipolar transistor (SiGe HBT) irradiated by 100-MeV proton is investigated. The simulation results indicate that the most sensitive position of the SiGe HBT device is the emitter center, where the protons pass through the larger collector-substrate (CS) junction. Furthermore, in this work the experimental studies are also carried out by using 100-MeV proton. In order to consider the influence of temperature on SEE, both simulation and experiment are conducted at a temperature of 93 K. At a cryogenic temperature, the carrier mobility increases, which leads to higher transient current peaks, but the duration of the current decreases significantly. Notably, at the same proton flux, there is only one single event transient (SET) that occurs at 93 K. Thus, the radiation hard ability of the device increases at cryogenic temperatures. The simulation results are found to be qualitatively consistent with the experimental results of 100-MeV protons. To further evaluate the tolerance of the device, the influence of proton on SiGe HBT after gamma-ray (60Co gamma) irradiation is investigated. As a result, as the cumulative dose increases, the introduction of traps results in a significant reduction in both the peak value and duration of the transient currents.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Investigation of technology scaling effect on SiGe HBT oscillator phase noise using impulse sensitivity function
    Tang, J
    Niu, GF
    Sheridan, D
    PROCEEDINGS OF THE 2005 BIPOLAR/BICMOS CIRCUITS AND TECHNOLOGY MEETING, 2005, : 260 - 263
  • [32] Experimental investigation on the degradation of SiGe LNAs under different bias conditions induced by 3 MeV proton irradiation
    Li, Zhuoqi
    Liu, Shuhuan
    Ren, Xiaotang
    Adekoya, Mathew Adefusika
    Zhang, Jun
    Liu, Shuangying
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (02) : 661 - 665
  • [33] Development of the integrated control system for the microwave ion source of the PEFP 100-MeV proton accelerator
    Song, Young-Gi
    Seol, Kyung-Tae
    Jang, Ji-Ho
    Kwon, Hyeok-Jung
    Cho, Yong-Sub
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2012, 61 (02) : 208 - 212
  • [34] PRODUCTION OF LI, BE AND B BY 65-MEV AND 100-MEV PROTON-INDUCED REACTIONS ON C-12
    ROCHE, CT
    CLARK, RG
    VIOLA, VE
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1973, 18 (04): : 651 - 651
  • [35] Estimation of the radiation field distribution induced by beam loss at the 100-MeV proton linear accelerator
    Sang-Pil Yoon
    Journal of the Korean Physical Society, 2013, 63 : 1332 - 1336
  • [36] Improvement of the Low-level RF Control System for the PEFP 100-MeV Proton Accelerator
    Seol, Kyung-Tae
    Kwon, Hyeok-Jung
    Kim, Han-Sung
    Song, Young-Gi
    Cho, Yong-Sub
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (02) : 627 - 630
  • [37] Development of the integrated control system for the microwave ion source of the PEFP 100-MeV proton accelerator
    Young-Gi Song
    Kyung-Tae Seol
    Ji-Ho Jang
    Hyeok-Jung Kwon
    Yong-Sub Cho
    Journal of the Korean Physical Society, 2012, 61 : 208 - 212
  • [38] Estimation of the radiation field distribution induced by beam loss at the 100-MeV proton linear accelerator
    Yoon, Sang-Pil
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2013, 63 (07) : 1332 - 1336
  • [39] The proton irradiation facility for Single-Event effect testing in CIAE*
    Zhang, Yan-Wen
    Guo, Gang
    Liu, Jian-Cheng
    Han, Jin-Hua
    Qin, Ying-Can
    Yin, Qian
    Xiao, Shu-Yan
    Yang, Xin-Yu
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 2022, 517 : 43 - 48
  • [40] The proton irradiation facility for Single-Event effect testing in CIAE
    Zhang, Yan-Wen
    Guo, Gang
    Liu, Jian-Cheng
    Han, Jin-Hua
    Qin, Ying-Can
    Yin, Qian
    Xiao, Shu-Yan
    Yang, Xin-Yu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2022, 517 : 43 - 48