A Dual-Energy Metal Artifact Redcution Method for DECT Image Reconstruction

被引:0
|
作者
Lyu, Tianling [1 ]
Zhao, Wei [2 ,3 ]
Gao, Wei [4 ]
Zhu, Jian [6 ]
Xi, Yan [7 ]
Chen, Yang [4 ,5 ]
Zhu, Wentao [1 ]
机构
[1] Zhejiang Lab, Hangzhou, Peoples R China
[2] Beihang Univ, Sch Phys, Beijing, Peoples R China
[3] Beihang Hangzhou Innovat Inst, Hangzhou, Peoples R China
[4] Southeast Univ, Dept Comp Sci & Technol, Lab Imaging Sci & Technol, Nanjing, Peoples R China
[5] Southeast Univ, Jiangsu Prov Joint Int Res Lab Med Informat Proc, Nanjing, Peoples R China
[6] Shandong First Med Univ, Canc Hosp, Dept Radiat Phys & Technol, Jinan, Peoples R China
[7] Shanghai First Imaging Tech, Shanghai, Peoples R China
关键词
metal artifact reduction; dual-energy CT; material decomposition; NMAR; REDUCTION; CT; ALGORITHM;
D O I
10.1109/EMBC40787.2023.10340221
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Metal implants are one of the culprits for image quality degradation in CT imaging, introducing so-called metal artifacts. With the help of the virtual-monochromatic imaging technique, dual-energy CT has been proven to be effective in metal artifact reduction. However, the virtual monochromatic images with suppressed metal artifacts show reduced CNR compared to polychromatic images. To remove metal artifacts on polychromatic images, we propose a dual-energy NMAR (deNMAR) algorithm in this paper that adds material decomposition to the widely used NMAR framework. The dual energy sinograms are first decomposed into water and bone sinograms, and metal regions are replaced with water on the reconstructed material maps. Prior sinograms are constructed by polyenergetically forward projecting the material maps with corresponding spectra, and they are used to guide metal trace interpolation in the same way as in the NMAR algorithm. We performed experiments on authentic human body phantoms, and the results show that the proposed deNMAR algorithm achieves better performance in tissue restoration compared to other compelling methods. Tissue boundaries become clear around metal implants, and CNR rises to 2.58 from similar to 1.70 on 80 kV images compared to other dual-energy-based algorithms.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Analysis of metal artifact reduction tools for dental hardware in CT scans of the oral cavity: kVp, iterative reconstruction, dual-energy CT, metal artifact reduction software: does it make a difference?
    De Crop, An
    Casselman, Jan
    Van Hoof, Tom
    Dierens, Melissa
    Vereecke, Elke
    Bossu, Nicolas
    Pamplona, Jaime
    D'Herde, Katharina
    Thierens, Hubert
    Bacher, Klaus
    NEURORADIOLOGY, 2015, 57 (08) : 841 - 849
  • [42] DECT-CLUST: Dual-Energy CT Image Clustering and Application to Head and Neck Squamous Cell Carcinoma Segmentation
    Chamroukhi, Faicel
    Brivet, Segolene
    Savadjiev, Peter
    Coates, Mark
    Forghani, Reza
    DIAGNOSTICS, 2022, 12 (12)
  • [43] Dual energy CT angiography: pros and cons of dual-energy metal artifact reduction algorithm in patients after endovascular aortic repair
    Johannes Boos
    Jieming Fang
    Benedikt H. Heidinger
    Vassilios Raptopoulos
    Olga R. Brook
    Abdominal Radiology, 2017, 42 : 749 - 758
  • [44] Dual energy CT angiography: pros and cons of dual-energy metal artifact reduction algorithm in patients after endovascular aortic repair
    Boos, Johannes
    Fang, Jieming
    Heidinger, Benedikt H.
    Raptopoulos, Vassilios
    Brook, Olga R.
    ABDOMINAL RADIOLOGY, 2017, 42 (03) : 749 - 758
  • [45] Metal Artifact Reduction by Dual-Energy Computed Tomography Using Energetic Extrapolation A Systematically Optimized Protocol
    Meinel, Felix G.
    Bischoff, Bernhard
    Zhang, Qiaowei
    Bamberg, Fabian
    Reiser, Maximilian F.
    Johnson, Thorsten R. C.
    INVESTIGATIVE RADIOLOGY, 2012, 47 (07) : 406 - 414
  • [46] Dual-energy iterative reconstruction for material characterisation
    Recur, B.
    Paziresh, M.
    Myers, G.
    Kingston, A.
    Latham, S.
    Sheppard, A.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [47] A dual-energy CT reconstruction method based on anchor network from dual quarter scans
    Ren, Junru
    Zhang, Wenkun
    Wang, YiZhong
    Liang, Ningning
    Wang, Linyuan
    Cai, Ailong
    Wang, Shaoyu
    Zheng, Zhizhong
    Li, Lei
    Yan, Bin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (02) : 229 - 252
  • [48] A CONSTRAINED DUAL-ENERGY RECONSTRUCTION METHOD FOR MATERIAL-SELECTIVE TRANSMISSION TOMOGRAPHY
    CLINTHORNE, NH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 353 (1-3): : 347 - 348
  • [49] Phantom-based optimization of virtual monoenergetic image reconstruction in dual-energy CT
    Richter, Anne
    Razinskas, Gary
    Weick, Stefan
    Lutyj, Paul
    Kraft, Johannes
    Wittig-Sauerwein, Andrea
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3848 - S3849
  • [50] Dual-energy Computed Tomography (DECT) in Renal Masses: Nonlinear versus Linear Blending
    Ascenti, Giorgio
    Krauss, Bernhard
    Mazziotti, Silvio
    Mileto, Achille
    Settineri, Nicola
    Vinci, Sergio
    Donato, Rocco
    Gaeta, Michele
    ACADEMIC RADIOLOGY, 2012, 19 (10) : 1186 - 1193