Computational study of the effect of building height on the performance of roof-mounted VAWT

被引:5
|
作者
Rezaei, Farshad [1 ]
Paraschivoiu, Marius [1 ]
机构
[1] Concordia Univ, Dept Mech Ind & Aerosp Engn, Montreal, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Vertical axis wind turbine; Computational fluid dynamics; Roof-top of building; Power coefficient; Building's height; AXIS WIND-TURBINE; AERODYNAMIC PERFORMANCE; CFD SIMULATIONS; DOMAIN SIZE; FLOW; ENERGY; DESIGN; OPTIMIZATION; MODELS; TUNNEL;
D O I
10.1016/j.jweia.2023.105540
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The power of a Vertical Axis Wind Turbine (VAWT) placed at the frontal corner of a roof-top of a building is significantly higher compared to the same turbine in a uniform wind without a surrounding building. Due to the importance of this configuration's benefits, it is crucial to study its effect for different building heights. To investigate the impact of building height on the power performance of VAWTs, three buildings with heights of 30.48 m (100 ft), 60.96 m (200 ft), and 91.44 m (300 ft) are considered. A two-blade Darrieus-type VAWT is placed on the roof-top, with the wind flow directed straight towards the corner of the building. Computational Fluid Dynamics (CFD) is utilized to simulate the entire flow over the building and the rotating turbine. Different atmospheric boundary wind velocity profiles are considered. Firstly, the same velocity profile is applied to all three buildings, with taller buildings experiencing higher velocities. Secondly, three distinct velocity profiles are used over the buildings, ensuring that the wind velocity at the middle of the turbine for each case remains at 9.3 m/s. The results demonstrate that placing the VAWT on the roof-top of a 30.48 m (100 ft) building increases the maximum Power Coefficient (CP) by 36% compared to the turbine operating in a uniform flow. Moreover, in the case of one velocity profile applied to buildings with different heights, it was observed that the maximum CP increased by 84% for a building with a height of 91.44 m compared to the turbine operating in uniform flow. On the other hand, in the second scenario with three different velocity profiles over the buildings, it was found that the maximum CP increased by 18% and 22% when the turbine was placed in the 60.96 m and 91.44 m buildings, respectively, compared to the 30.48 m building.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] Effect of roof-mounted solar panels on the wind energy exploitation on high-rise buildings
    Toja-Silva, Francisco
    Peralta, Carlos
    Lopez-Garcia, Oscar
    Navarro, Jorge
    Cruz, Ignacio
    JOURNAL OF WIND ENGINEERING AND INDUSTRIAL AERODYNAMICS, 2015, 145 : 123 - 138
  • [22] Environmental payback time analysis of a roof-mounted building-integrated photovoltaic (BIPV) system in Hong Kong
    Lu, L.
    Yang, H. X.
    APPLIED ENERGY, 2010, 87 (12) : 3625 - 3631
  • [23] Performance Enhancement of Roof-Mounted Photovoltaic System: Artificial Neural Network Optimization of Ground Coverage Ratio
    Alghamdi, Ali S.
    ENERGIES, 2021, 14 (06)
  • [24] Computational fluid dynamic analysis of roof-mounted vertical-axis wind turbine with diffuser shroud, flange, and vanes
    Abu-Thuraia, H.
    Aygun, C.
    Paraschivoiu, M.
    Allard, M. A.
    TRANSACTIONS OF THE CANADIAN SOCIETY FOR MECHANICAL ENGINEERING, 2018, 42 (04) : 404 - 415
  • [25] Performance Investigation of Roof-Mounted PV Systems in Snowy Conditions Considering Snow Coverage and Snow Removal Process
    Mohammadi, Ebrahim
    Moschopoulos, Gerry
    2020 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM), 2020,
  • [26] Early performance for the roof-mounted, 20-kW thin film CdTePV-array at Jasper Ridge
    Scofield, JH
    Cohen, P
    Tronson, C
    Gould, S
    CONFERENCE RECORD OF THE THIRTY-FIRST IEEE PHOTOVOLTAIC SPECIALISTS CONFERENCE - 2005, 2005, : 1623 - 1626
  • [27] Influence of incoming turbulence and shear on the flow field and performance of a lab-scale roof-mounted vertical axis wind turbine
    Jooss, Y.
    Hearst, R. J.
    Bracchi, T.
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2023, 15 (06)
  • [28] Assessment and performance analysis of roof-mounted crystalline stand-alone photovoltaic (SAPV) system at selected sites in South Africa
    Williams S. Ebhota
    Pavel Y. Tabakov
    Bulletin of the National Research Centre, 46 (1)
  • [29] Comprehensive optimization of shading and electrical performance of roof-mounted photovoltaic system of Venlo-type greenhouse in the severe cold region
    Jin, Yang
    Jiang, Wei
    Han, Yang
    Nan, Songyu
    Liu, Gongliang
    Guo, Wei
    Zhang, Kuan
    Li, Qing
    Li, Dong
    ENERGY, 2024, 296
  • [30] Boosting Solar Sustainability: Performance Assessment of Roof-Mounted PV Arrays Under Snow Considering Various Module Interconnection Schemes
    Mohammadi, Ebrahim
    Moschopoulos, Gerry
    Chen, Aoxia
    SUSTAINABILITY, 2025, 17 (01)