Computational study of the effect of building height on the performance of roof-mounted VAWT

被引:5
|
作者
Rezaei, Farshad [1 ]
Paraschivoiu, Marius [1 ]
机构
[1] Concordia Univ, Dept Mech Ind & Aerosp Engn, Montreal, PQ, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Vertical axis wind turbine; Computational fluid dynamics; Roof-top of building; Power coefficient; Building's height; AXIS WIND-TURBINE; AERODYNAMIC PERFORMANCE; CFD SIMULATIONS; DOMAIN SIZE; FLOW; ENERGY; DESIGN; OPTIMIZATION; MODELS; TUNNEL;
D O I
10.1016/j.jweia.2023.105540
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The power of a Vertical Axis Wind Turbine (VAWT) placed at the frontal corner of a roof-top of a building is significantly higher compared to the same turbine in a uniform wind without a surrounding building. Due to the importance of this configuration's benefits, it is crucial to study its effect for different building heights. To investigate the impact of building height on the power performance of VAWTs, three buildings with heights of 30.48 m (100 ft), 60.96 m (200 ft), and 91.44 m (300 ft) are considered. A two-blade Darrieus-type VAWT is placed on the roof-top, with the wind flow directed straight towards the corner of the building. Computational Fluid Dynamics (CFD) is utilized to simulate the entire flow over the building and the rotating turbine. Different atmospheric boundary wind velocity profiles are considered. Firstly, the same velocity profile is applied to all three buildings, with taller buildings experiencing higher velocities. Secondly, three distinct velocity profiles are used over the buildings, ensuring that the wind velocity at the middle of the turbine for each case remains at 9.3 m/s. The results demonstrate that placing the VAWT on the roof-top of a 30.48 m (100 ft) building increases the maximum Power Coefficient (CP) by 36% compared to the turbine operating in a uniform flow. Moreover, in the case of one velocity profile applied to buildings with different heights, it was observed that the maximum CP increased by 84% for a building with a height of 91.44 m compared to the turbine operating in uniform flow. On the other hand, in the second scenario with three different velocity profiles over the buildings, it was found that the maximum CP increased by 18% and 22% when the turbine was placed in the 60.96 m and 91.44 m buildings, respectively, compared to the 30.48 m building.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Enhancement of Performance of Roof-mounted SPV System
    Singh, Athokpam Bharatbushan
    Deshmukh, M. K.
    5TH INTERNATIONAL CONFERENCE ON POWER AND ENERGY SYSTEMS ENGINEERING (CPESE 2018), 2019, 156 : 105 - 109
  • [2] Decade performance of a roof-mounted photovoltaic array
    Begovic, Miroslav
    Ghosh, Seema R.
    Rohatgi, Ajeet
    CONFERENCE RECORD OF THE 2006 IEEE 4TH WORLD CONFERENCE ON PHOTOVOLTAIC ENERGY CONVERSION, VOLS 1 AND 2, 2006, : 2383 - +
  • [3] Wind environment at a roof-mounted wind turbine on a peaked roof building
    Hakimi, Rohan
    Lubitz, Andwilliam David
    INTERNATIONAL JOURNAL OF SUSTAINABLE ENERGY, 2016, 35 (02) : 172 - 189
  • [4] Performance analysis of roof-mounted photovoltaic systems - The case of a Norwegian residential building
    Madessa, Habtamu B.
    SUSTAINABILITY IN ENERGY AND BUILDINGS: PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE SEB-15, 2015, 83 : 474 - 483
  • [5] Computational Investigation of Wind Loads on Tilted Roof-Mounted Solar Array
    Tu, Zhibin
    Zheng, Gensheng
    Yao, Jianfeng
    Shen, Guohui
    Lou, Wenjuan
    SUSTAINABILITY, 2022, 14 (23)
  • [6] THE APPLICATION OF COMPUTATIONAL FLUID DYNAMICS FOR INSTALLING THE ROOF-MOUNTED WIND TURBINE
    Lu, Lu
    Wang, Xiuling
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION - 2012, VOL 7, PTS A-D, 2013, : 633 - 642
  • [7] Effect of Cape storms on the flat roof-mounted solar panels
    Kiama, Y.
    Mahachi, J.
    CURRENT PERSPECTIVES AND NEW DIRECTIONS IN MECHANICS, MODELLING AND DESIGN OF STRUCTURAL SYSTEMS, 2022, : 47 - 48
  • [8] Effect of Cape storms on the flat roof-mounted solar panels
    Kiama, Y.
    Mahachi, J.
    CURRENT PERSPECTIVES AND NEW DIRECTIONS IN MECHANICS, MODELLING AND DESIGN OF STRUCTURAL SYSTEMS, 2022, : 138 - 143
  • [9] Evaluation of the thermal performance of a roof-mounted radiant barrier in residential buildings: Experimental study
    Asadi, Somayeh
    Hassan, Marwa M.
    JOURNAL OF BUILDING PHYSICS, 2014, 38 (01) : 66 - 80
  • [10] Investigation of Cooling Techniques for Roof-Mounted Silicon Photovoltaic Panels in the Climate of the UAE: A Computational and Experimental Study
    Abdelaty, Tarek
    Chaudhry, Hassam Nasarullah
    Calautit, John Kaiser
    ENERGIES, 2023, 16 (18)