Quasi-static pipeline in electroconvulsive therapy computational modeling

被引:4
|
作者
Unal, Gozde [1 ]
Poon, Cynthia [1 ]
FallahRad, Mohamad [1 ]
Thahsin, Myesha [1 ]
Argyelan, Miklos [2 ]
Bikson, Marom [1 ]
机构
[1] CUNY, Dept Biomed Engn, New York, NY 10031 USA
[2] North Shore Long Isl Jewish Hlth Syst, Feinstein Inst Med Res, Ctr Neurosci, Manhasset, NY 11030 USA
基金
美国国家卫生研究院;
关键词
DEEP BRAIN-STIMULATION; SEIZURE THRESHOLD; ELECTRICAL-PROPERTIES; UNIFORM ASSUMPTION; SKIN IMPEDANCE; DC STIMULATION; ECT; STIMULUS; EXCITATION; TISSUE;
D O I
10.1016/j.brs.2023.03.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: Computational models of current flow during Electroconvulsive Therapy (ECT) rely on the quasi-static assumption, yet tissue impedance during ECT may be frequency specific and change adaptively to local electric field intensity.Objectives: We systematically consider the application of the quasi-static pipeline to ECT under conditions where 1) static impedance is measured before ECT and 2) during ECT when dynamic impedance is measured. We propose an update to ECT modeling accounting for frequency-dependent impedance.Methods: The frequency content on an ECT device output is analyzed. The ECT electrode-body impedance under low-current conditions is measured with an impedance analyzer. A framework for ECT modeling under quasi-static conditions based on a single device-specific frequency (e.g., 1 kHz) is proposed.Results: Impedance using ECT electrodes under low-current is frequency dependent and subject specific, and can be approximated at >100 Hz with a subject-specific lumped parameter circuit model but at <100 Hz increased non-linearly. The ECT device uses a 2 mA 800 Hz test signal and reports a static impedance that approximate 1 kHz impedance. Combined with prior evidence suggesting that conductivity does not vary significantly across ECT output frequencies at high-currents (800-900 mA), we update the adaptive pipeline for ECT modeling centered at 1 kHz frequency. Based on individual MRI and adaptive skin properties, models match static impedance (at 2 mA) and dynamic impedance (at 900 mA) of four ECT subjects.Conclusions: By considering ECT modeling at a single representative frequency, ECT adaptive and nonadaptive modeling can be rationalized under a quasi-static pipeline.& COPY; 2023 The Authors. Published by Elsevier Inc. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
引用
下载
收藏
页码:607 / 618
页数:12
相关论文
共 50 条
  • [41] Quasi-static brittle fracture
    Pfaendtner, JA
    Muthiah, RC
    McMahon, CJ
    FRACTURE AND DUCTILE VS. BRITTLE BEHAVIOR-THEORY, MODELLING AND EXPERIMENT, 1999, 539 : 313 - 318
  • [42] QUASI-STATIC CRACKING IN POLYCARBONATE
    MAI, YW
    INTERNATIONAL JOURNAL OF FRACTURE, 1973, 9 (03) : 349 - 351
  • [43] Nonlinear quasi-static poroelasticity
    Bociu, Lorena
    Webster, Justin T.
    JOURNAL OF DIFFERENTIAL EQUATIONS, 2021, 296 : 242 - 278
  • [44] QUASI-STATIC ADHESIVE FRACTURE
    MAI, YW
    JOURNAL OF ADHESION, 1975, 7 (02): : 141 - 153
  • [45] Quasi-static brittle fracture
    Dept. of Materials Science and Engineering, Univ. of Pennsylvania, Philadelphia, PA 19104, United States
    不详
    不详
    Mater Res Soc Symp Proc, (313-318):
  • [46] Quasi-static large deviations
    De Masi, Anna
    Olla, Stefano
    ANNALES DE L INSTITUT HENRI POINCARE-PROBABILITES ET STATISTIQUES, 2020, 56 (01): : 524 - 542
  • [47] Quasi-Static Hydrodynamic Limits
    Anna De Masi
    Stefano Olla
    Journal of Statistical Physics, 2015, 161 : 1037 - 1058
  • [48] QUASI-STATIC GROWTH OF CRACKS
    CHUDNOVSKII, AI
    DUNAEVSKII, VA
    KHANDOGIN, VA
    ARCHIVES OF MECHANICS, 1978, 30 (02): : 165 - 174
  • [49] Static and quasi-static calibration of a bioMEMS device
    Slifka, AJ
    Panchawagh, H
    Mahajan, RL
    Finch, D
    Rorrer, RAL
    BIOMEDICAL SCIENCES INSTRUMENTATION, VOL 40, 2004, 449 : 429 - 434
  • [50] The quasi-static method revisited
    Dulla, Sandra
    Mund, Ernest H.
    Ravetto, Piero
    PROGRESS IN NUCLEAR ENERGY, 2008, 50 (08) : 908 - 920